Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community; see Additional Resources.

Bug Number

Legacy ID

Description

Details

2758044

Output Cutoff on PXIe-4135/6/7 may cause errors when used in conjunction with Measurement Autorange

When using Output Cutoff and Measurement Autorange on the NI PXIe-4135, PXIe-4136, or PXIe-4137, the instrument may return error -1074116059 ("Specified operation did not complete") or error -235140 ("Internal Hardware Error").

Workaround:

Do not enable Output Cutoff at the same time as Measurement Autorange.

Reported Version:

NI-DCPower 2024 Q2, NI-DCPower 2024 Q3

Resolved Version:

N/A

Added:

N/A

2558394, 2807457

Calling niDCPower Wait for Event on multiple channels simultaneously will rarely return error -1074116981 on the PXIe-4162 and PXIe-4163

When niDCPower Wait for Event is called using the Measure Complete Event on multiple channels on a PXIe-4162 or PXIe-4163 in parallel, a channel will occasionally return an internal hardware error, -1074116981.

Once in this state, the error can only be cleared by performing a device reset.

The error message looks similar to the following:
Error -1074116981 occurred at niDCPower Wait For Event.vi

Possible reason(s):
Internal Hardware Error. Contact NI support.
Additional Error Info: Applicable Iso Captured: [RegPortDcBusTxOverflow]


Workaround:

Use a simple for loop instead of parallel for loop around the niDCPower Wait for Event (using Measure Complete Event) function call.

Reported Version:

NI-DCPower 2023 Q4

Resolved Version:

N/A

Added:

N/A

Final Time Issue Listed

Issues found in this section will not be listed in future known issues documents for this product.

There are currently no issues to list.

Additional Resources

Explore Support Content and Product Documentation 

 

 

Ask the NI Community

 

 

Request Support from an Engineer

 

A valid service agreement may be required, and support options vary by country

 

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).