The following items are notable issues fixed between the release of RFIC Test Software 22.0 and RFIC Test Software 22.5, including additional patches and service packs. If you have an issue ID, you can search this list to validate that the issue has been fixed. This is not an exhaustive list of issues fixed in the current version of RFIC Test Software.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
2253796 |
RFIC SFP Displays the EVM Measurement Result of the First Carrier in All Carriers for NR Multi-Carrier SignalsThe RFIC SFP displays the EVM measurement result of the first
carrier in all carriers for NR multi-carrier signals.
Workaround: View the EVM measurement results for NR multi-carrier signals in the RFmx NR SFP.
|
Reported Version: RFIC Test Software: 22.0 Resolved Version: RFIC Test Software: 22.5 Added: N/A |
|
2287479 |
RFIC SFP Cannot Perform Frequency Sweep Measurements in Certain CasesWhen
performing frequency sweep measurements, if Start
Freq (Hz) is different from RF Center
Frequency(Hz) and the external local oscillator (LO) is shared between
the VSA and the VSG, RFIC SFP returns the following error:
Workaround: Turn off LO sharing by setting LO Sharing to Not Shared on HW Configuration » VSG.
|
Reported Version: RFIC Test Software: 22.0 Resolved Version: RFIC Test Software: 22.5 Added: N/A |
Installing some patches may require certain additional steps or considerations. Please refer to the following table for more information about patches for this release.
These patches currently do not have any special instructions.