The following items are notable issues fixed between the release of NI-XNET 2023 Q2 and NI-XNET 2023 Q4, including additional patches and service packs. If you have an issue ID, you can search this list to validate that the issue has been fixed. This is not an exhaustive list of issues fixed in the current version of NI-XNET.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
2251664 |
Sending Multiple Data as Frames on AssignFrameIdRange is not SupportedThe LIN Specification indicates that multiple bits can be sent in a frame. If AssignFrameIdRange is used multiple times in a schedule, some data is lost and random values appear at the end of the
command. The following image compares the data used in the LDF file with the
data imported by NI-XNET. ![]() Workaround: There is currently no known workaround for this issue. |
Reported Version: NI-XNET 2022 Q3 Resolved Version: NI-XNET 2023 Q4 Added: Apr 10, 2023 |
|
2250040 |
Burst of Frames Is Sent After J1939 Single-Point Session of Cyclic Frames ResumesAfter a J1939
Single-Point session of cyclic frames has been stopped and then restarted, NI-XNET sends a quick burst of transport protocol frames. See related bug 2261309, Messages Stay Paused After J1939 Single-Point Session of Cyclic Frames Resumes. Workaround: There is currently no known workaround for this issue. |
Reported Version: NI-XNET 20.0 Resolved Version: NI-XNET 2023 Q4 Added: N/A |
|
2251215 |
NI-XNET Component Fails to Load When Added to a LabVIEW ProjectWhen an XNET palette item is added to a blank VI in a
LabVIEW project, a conflict occurs in the project explorer dependency tree. After the project has been saved and closed, the component points to the wrong VI
paths. ![]() Workaround: First create the VI with the XNET content, and only then add it to the project and save the project. |
Reported Version: NI-XNET 2023 Q1 Resolved Version: NI-XNET 2023 Q4 Added: Mar 10, 2023 |
|
2360396 |
"File not Found" Message Appears When User Tries to Access XNET LV Project Examples on LinuxA "File not Found" message is displayed when users try to use the NI Example Finder to access NI-XNET LabVIEW project examples on Linux. The projects directory that is installed for Windows environments cannot yet be installed on Linux machines. ![]() Workaround: Access LabVIEW project examples on Windows platform.
|
Reported Version: NI-XNET 21.0 Resolved Version: NI-XNET 2023 Q4 Added: Mar 10, 2023 |
Installing some patches may require certain additional steps or considerations. Please refer to the following table for more information about patches for this release.
These patches currently do not have any special instructions.