This document contains the NI-VRTS known issues that were discovered before and since the release of NI-VRTS 19.0 and 20.0. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.
Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community; see Additional Resources.
Issues found in this section will not be listed in future known issues documents for this product.
There are currently no issues to list.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
1774263 |
For 1 GHz VRTS, Delay and Gain between VDG and VST Is Not ConfigurableIndividual systems may require adjusting these values depending on cables and system configuration.
Workaround: There is currently no known workaround for this issue. |
Reported Version: NI-VRTS: 19.0 Resolved Version: NI-VRTS: 20.0 Added: N/A |
|
1774265 |
For 1 GHz VRTS, PXIe-5840 Calibration Coefficients Are Applied Incorrectly, Resulting in Incorrect Image Rejection and EqualizationThis issue results in incorrect gain for measurements using the PXIe-5840 as well as simulation of objects >95m using the PXIe-5840. Updating to NI-VRTS 20.0.1 is essential.
Workaround: There is currently no known workaround for this issue. |
Reported Version: NI-VRTS: 20.0 Resolved Version: NI-VRTS: 20.0.1 Added: N/A |
|
1774266 |
For 1 GHz VRTS, If LO Tuning Requires a Retry before Its PLL Locks, Any Preceding Warnings Will Be ClearedIn Configure.vi, NI-VRTS will make multiple attempts to tune the LOs to the requested frequency and ensure they are locked. If the first attempt does not succeed, any warnings passed on the error wire will be cleared.
Workaround: There is currently no known workaround for this issue. |
Reported Version: NI-VRTS: 20.0 Resolved Version: NI-VRTS: 20.0.1 Added: N/A |
|
1774267 |
For 1 GHz VRTS, No Error is Reported When a PLL Fails to LockFor VRTS to function properly, multiple phase-locked loops (PLLs) on the VDG and radio head must be locked to their reference input. Prior to NI-VRTS 20.0, if a PLL fails to lock, an error was not reported.
Workaround: There is currently no known workaround for this issue. |
Reported Version: NI-VRTS: 19.0 Resolved Version: NI-VRTS: 20.0 Added: N/A |
|
1774268 |
System Configuration API Does Not Update When a 4 GHz VRTS Radio Head Is Added or RemovedThis affects MAX, as well as any System Configuration API session in LabVIEW or elsewhere.
Workaround: To refresh, close and reopen MAX or LabVIEW.
|
Reported Version: NI-VRTS: 19.0 Resolved Version: N/A Added: N/A |