FlexRIO 2023 Q4 Known Issues

Overview

This document contains the FlexRIO known issues that were discovered before and since the release of FlexRIO 2023 Q4. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.

 

Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community; see Additional Resources.

Bug Number

Legacy ID

Description

Details

2296986, 2348644

PXIe-7903 or PXIe-6954 will fail to compile a bitfile if LabVIEW is not run in administrator mode

When run from LabVIEW without administrator privileges, PXIe-7903 or PXIe-6954 FPGA applications will fail to compile bitfiles in the codegen step due to permissions error copying files to the lvaddons directory. 

Workaround:

Run LabVIEW in Administrator mode when compiling bitfiles.

Reported Version:

FlexRIO 2023 Q1

Resolved Version:

N/A

Added:

N/A

2349383

PXIe-7903 100GbE example does not respond to ARP requests

The PXIe 100GbE example doesn't respond to ARP requests sent to it by connected systems. This can manifest as data sent to a Sasquatch not being received, because the connected system doesn't know where to send the data.

Workaround:

Manually configure the ARP table of the system connected to the Sasquatch. On Windows this can be done with the command `arp -s <sasquatch IP> <sasquatch MAC> <IP of sending NIC>`. e.g. `arp -s 169.254.122.138 01-02-03-04-05-06 169.254.122.137`

Reported Version:

FlexRIO 2023 Q2

Resolved Version:

N/A

Added:

N/A

PXIe-7890 Errors when Being Added as a Target in LabVIEW 2021

Adding a PXIe-7890 may report an error when being added as a target in LabVIEW 2021. The error message will be "An internal software error has occurred in LabVIEW FPGA". 

Workaround:

There are 2 possible workarounds -

  1. Use LabVIEW 2023 Q1 or later instead of LabVIEW 2021
  2. On a fresh system, first install LabVIEW 2023 Q1 or later on the system, followed by LabVIEW 2021 and the FlexRIO driver. This will enable using LabVIEW 2021 and the FlexRIO driver to add a PXIe-7890 as a target

Reported Version:

FlexRIO 2023 Q2

Resolved Version:

N/A

Added:

N/A

Final Time Issue Listed

Issues found in this section will not be listed in future known issues documents for this product.

There are currently no issues to list.

Additional Resources

Explore Support Content and Product Documentation 

 

 

Ask the NI Community

 

 

Request Support from an Engineer

 

A valid service agreement may be required, and support options vary by country

 

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).