The following items are notable issues fixed between the release of SystemLink 2020 R4 and SystemLink 2021 R1, including additional patches and service packs. If you have an issue ID, you can search this list to validate that the issue has been fixed. This is not an exhaustive list of issues fixed in the current version of SystemLink.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
1173892 |
Calibration support cannot be removed from 3rd party assetsIf you enable external calibration support for a 3rd party asset you cannot remove it later.
Workaround: Manually edit the JSON file storing the asset information C:\ProgramData\National Instruments\Skyline\Data\Assets\UserDefined\_server and remove the externalCalibration section.
|
Reported Version: SystemLink 2020 R4 Resolved Version: SystemLink 2021 R1 Added: Dec 10, 2020 |
|
1179296 |
There is no progress information when adding, updating, or removing an assetThere is no progress information displayed from the asset grid when adding, updating, or removing an asset in a system.
Workaround: Use the History tab in the system's detail view to monitor the asset job history. |
Reported Version: SystemLink 2020 R4 Resolved Version: SystemLink 2021 R1 Added: Dec 10, 2020 |
|
1137631 |
Background monitoring can cause tests to periodically failSystemLink periodically reads the calibration and temperature information for all NI assets every 5 minutes. If SystemLink is reading the temperature at the exact same time an automated test is run it can cause the test to fail if the driver reserves the device while in use.
Workaround: Lock your systems before running tests from SystemLink. This will prevent the background tasks from running.
|
Reported Version: SystemLink 2020 R3 Resolved Version: SystemLink 2021 R1 Added: Dec 10, 2020 |
|
1172750 |
Parametric data viewer hangs when many test results are selectedSelecting a large number of test results in the test result grid (1000+) and then clicking View > Parametric Data, the Parametric Data Viewer hangs and there is an exception in the console.
Workaround: Select fewer test results until the resulting URL length is less than the browser limit. There is no way to send 1000 results into the Parametric Data Viewer.
|
Reported Version: SystemLink 2020 R1 Resolved Version: SystemLink 2021 R1 Added: Dec 14, 2020 |
|
1239960 |
Test Module's TestStand Store and Forward feature sometimes gets stuckThe "Enable Store and Forward when Disconnected from Server" feature of the SystemLink Result Processing Plugin for TestStand does not work properly. Workaround: There is currently no known workaround for this issue. |
Reported Version: SystemLink 2020 R3 Resolved Version: SystemLink 2021 R1 Added: Mar 26, 2021 |
|
1233611 |
DataFinder - column-oriented query fails if file size of one or more files is greater than MAX INT32 (4GB)Workaround: There is currently no known workaround for this issue. |
Reported Version: SystemLink 2020 R4 Resolved Version: SystemLink 2021 R1 Added: Apr 14, 2021 |
|
1239601 |
DataFinder HTTP API for Security Settings is DeprecatedDetails: Due to the new Auth service the following routes do no longer function: /datafinders/{df_uuid}/searchareas/{sa_uuid}/security… /datafinders/{df_uuid}/security Workaround: Use SystemLink Auth Service to configure security settings.
|
Reported Version: SystemLink 2020 R2 Resolved Version: SystemLink 2021 R1 Added: Apr 27, 2021 |
|
1338001 |
[Python SDK] systemlink.clients.nitdmreader.api.metadata_api.MetadataApi.get_all_file_info doesn't return requested Python objectsWorkaround: Use 'get_multiple_file_info' as alternative.
|
Reported Version: SystemLink 2020 R4 Resolved Version: SystemLink 2021 R1 Added: Apr 27, 2021 |
|
1346955 |
Optimizing custom properties times out in case of huge property count.Workaround: There is currently no known workaround for this issue. |
Reported Version: SystemLink 2020 R4 Resolved Version: SystemLink 2021 R1 Added: N/A |
|
1356899 |
[Analysis Automation] Scheduled task with recurrence interval set to month does not work correctlyWorkaround: There is currently no known workaround for this issue. |
Reported Version: SystemLink 19.6 Resolved Version: SystemLink 2021 R1 Added: Apr 27, 2021 |
|
1400389 |
[Data Indexing] An altered database path of a previous version is discarded after an upgradeWorkaround: There is currently no known workaround for this issue. |
Reported Version: SystemLink 2020 R2 Resolved Version: SystemLink 2021 R1 Added: Apr 27, 2021 |
|
1422638, 1433322 |
[Analysis Automation] Manual approval of Analysis Procedures required after upgradeWhen upgrading from a SystemLink version prior to 2021, existing procedures are not approved automatically. However, existing and active tasks are still working, but cannot be edited and new tasks cannot be created, until the procedure has been approved.
Workaround: Manually approve the according Analysis Procedures.
|
Reported Version: SystemLink 2020 R4 Resolved Version: SystemLink 2021 R1.1 Added: Apr 27, 2021 |
|
1706828 |
DataFinder stopped because SL TDM Database Service crashedWorkaround: There is currently no known workaround for this issue. |
Reported Version: SystemLink 2021 R1 Resolved Version: SystemLink 2021 R1.2 Added: Nov 24, 2021 |
Installing some patches may require certain additional steps or considerations. Please refer to the following table for more information about patches for this release.