Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community.

Bug Number

Legacy ID

Description

Details

115960 572887

Setting the Frame Type Option in the Raw Data Frame Configuration Page Has no Effect

As the frame type is pulled from the XNET database, the system definition setting does not affect the XNET configuration.

Workaround:

Set the frame type in the XNET database. Do not use the Raw Data Frame Type Configuration option in the system definition.

Reported Version:

VeriStand 2014

Resolved Version:

N/A

Added:

Jan 17, 2020

114970

LIN Scheduler is started before the session resulting in 500 ms of no response frames.

When XNET is configured to be a LIN master, the LIN scheduler appears to start before the outgoing XNET sessions are started. This results in the LIN master scheduler transmitting headers while the master's slave task is unprepared to transmit responses. As a result, the receiving LIN interface will instead detect "No Response" frames.

Workaround:

If you do not need to inline outgoing frames, you can deselect this option and the issue will not occur.

Reported Version:

VeriStand 18.0

Resolved Version:

N/A

Added:

N/A

1069833

Show frame IDs in hexadecimal format setting not fully applied

Enabling the setting "Show frame IDs in hexadecimal format" does not completely apply. The ID in the name field remains in decimal, while the frame ID field updates properly to hexadecimal, but does not have a radix added.

Workaround:

There is currently no known workaround for this issue.

Reported Version:

VeriStand 2020

Resolved Version:

N/A

Added:

N/A

1095791

Deployment error -200077 with a module configured for HWTSP and Sample Rate less than 5 Hz

When enabling "Slow Background Conversion Mode" for a module and setting the Sample Rate to be less than 5 Hz, deployment will fail with error -200077.

Workaround:

Set the "Sample Rate" to either -1 or any value greater or equal than 5 Hz.

Reported Version:

VeriStand 2019

Resolved Version:

N/A

Added:

N/A

Final Time Issue Listed

Issues found in this section will not be listed in future known issues documents for this product.

There are currently no issues to list.

Additional Resources

Explore Support Content and Product Documentation 

 

 

Ask the NI Community

 

 

Request Support from an Engineer

 

A valid service agreement may be required, and support options vary by country

 

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).