The following items are notable issues fixed between the release of NI-RFSG Playback Library 20.0 and NI-RFSG Playback Library 20.6, including additional patches and service packs. If you have an issue ID, you can search this list to validate that the issue has been fixed. This is not an exhaustive list of issues fixed in the current version of NI-RFSG Playback Library.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
743302 |
Loss of Precision in Sampling Rate When Complex Waveforms are Passed as Parameters to .NET APIsConversion of sampling interval (dt) from double to PrecisionTimeSpan parameter causes slight loss in resolution of the data. This leads to precision error when sample rate is calculated as the inverse of the sampling interval obtained from PrecisionTimeSpan parameter. Impacted APIs: DownloadUserWavform and ReadWaveformFromFile
Workaround: Calculate the actual sample rate as “1/dt” and overwrite the sample rate using the StoreWaveformSampleRate API. |
Reported Version: NI-RFSG Playback Library: 19.0 Resolved Version: NI-RFSG Playback Library: 20.6 Added: Jun 2, 2020 |
Installing some patches may require certain additional steps or considerations. Please refer to the following table for more information about patches for this release.
These patches currently do not have any special instructions.