This document contains the NI-RFSG Playback Library 20.0 known issues that were discovered before and since the release of NI-RFSG Playback Library 20.0. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.
Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
743302 |
Loss of precision in sampling rate when complex waveforms are passed as parameters to .NET APIsConversion of sampling interval (dt) from double to PrecisionTimeSpan parameter causes slight loss in resolution of the data. This leads to precision error when sample rate is calculated as the inverse of the sampling interval obtained from PrecisionTimeSpan parameter. Impacted APIs: DownloadUserWavform and ReadWaveformFromFile
Workaround: Calculate the actual sample rate as “1/dt” and overwrite the sample rate using the StoreWaveformSampleRate API. |
Reported Version: NI-RFSG Playback Library 19.0 Resolved Version: N/A Added: Jun 2, 2020 |
Issues found in this section will not be listed in future known issues documents for this product.