This document contains the FlexLogger 2020 R1 known issues that were discovered before and since the release of FlexLogger 2020 R1. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.
Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
958021 |
Built-In CJC Not Selectable for PXIe-4302/3For the PXIe-4302 and PXIe-4303 modules, the option to select the Built-In CJC, which is provided by the terminal block, is not available.
Workaround: There is no option to select the Built-In CJC, but you can still select and configure a constant CJC Source.
|
Reported Version: FlexLogger 2020 R1 Resolved Version: FlexLogger 2020 R2 Added: Jan 17, 2020 |
|
1116657 |
Adding DAQ Channels in a Non-sequential Order Corrupts Anything Referencing a ChannelWhen new DAQ channels are configured in non-sequential order within a device (PXI, cDAQ, FieldDAQ, USB, etc.), any existing or future calculated channels, plugins, logging triggers, and events reference the wrong channel. This means that calculated channels and plugins will be operating on the wrong data and events and triggers may not fire when expected. To obtain more information, click the link below.
Workaround: Save and re-open your project after you have finished all new channel configurations and before you validate the project.
|
Reported Version: FlexLogger 2020 R1 | FlexLogger 2020 R2 | FlexLogger 2020 R3 Resolved Version: FlexLogger 2020 R4 Added: Sep 10, 2020 |
Issues found in this section will not be listed in future known issues documents for this product.
There are currently no issues to list.