The following items are notable issues fixed between the release of ECU Measurement and Calibration Toolkit 20.0 and ECU Measurement and Calibration Toolkit 20.6, including additional patches and service packs. If you have an issue ID, you can search this list to validate that the issue has been fixed. This is not an exhaustive list of issues fixed in the current version of ECU Measurement and Calibration Toolkit.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
977921 |
Application Crashes if an ECU Sends Unaligned Frames with PACKET_ALIGNMENT > 1A crash occurs when an ECU sends frames with a frame length that is not aligned to the PACKET_ALIGNMENT setting in the A2L file.
Workaround: There is currently no known workaround for this issue. |
Reported Version: ECU Measurement and Calibration Toolkit 19.5 Resolved Version: ECU Measurement and Calibration Toolkit 20.6 Added: Nov 19, 2020 |
|
1102466 |
Memory Leak When NI-XNET Echo Transmit is Active on the Same PortA memory leak can occur when an ECUMC session is used on the same interface on which an NI-XNET session was used with the interface option "Interface:Echo Transmit?" set to ON.
Workaround: There is currently no known workaround for this issue. |
Reported Version: ECU Measurement and Calibration Toolkit 20.1 Resolved Version: ECU Measurement and Calibration Toolkit 20.6 Added: Nov 19, 2020 |