The following items are notable issues fixed between the release of DIAdem 2019 SP1 and DIAdem 2020, including additional patches and service packs. If you have an issue ID, you can search this list to validate that the issue has been fixed. This is not an exhaustive list of issues fixed in the current version of DIAdem 2020.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
986831 |
REPORT: DIAdem calculates the number of intervals for the miniticks using the labeled ticks instead of the number of miniticks.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 Resolved Version: DIAdem 2020 Added: N/A |
|
987380 |
ANALYSIS: Compound classification using the Time-at-level 1 classification method according to DIN 45667 gives incorrect results if at least one of the input channels contains only NoValues.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2018 | DIAdem 2019 Resolved Version: DIAdem 2020 Added: N/A |
|
987389 |
ANALYSIS: If you want to calculate the FFT across more than one time interval, DIAdem does not display a warning that this is only possible for the first signal pair.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 Resolved Version: DIAdem 2020 Added: N/A |
|
987383 |
ANALYSIS: The "Resampling" dialog box does not allow the anti-aliasing filter if you use two waveform channels as y-channels.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 Resolved Version: DIAdem 2020 Added: N/A |
|
451844 |
ANALYSIS: The ChnEventCreateFilteredTrueChn function does not consider the first value of an event during an inplace operation.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 Resolved Version: DIAdem 2019 SP1 Added: N/A |
|
962516 |
ANALYSIS: If you apply the "Remove Duplicate" function to a channel with only one value, the result channel will be empty.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2017 | DIAdem 2018 | DIAdem 2019 Resolved Version: DIAdem 2019 SP1 Added: N/A |
|
452724 |
SCRIPT: The elements selected in a pie chart cannot be edited with a script using the SelectedElements property.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 Resolved Version: DIAdem 2019 SP1 Added: N/A |
|
221441 |
ANALYSIS: If you use a waveform channel as signal channel in the "FFT (one time signal)" function and have selected Octave for Third/Octave on the "FFT Functions" tab, DIAdem does not generate the result channel CenterFrequencyOctaveFrequency.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2017 | DIAdem 2018 | DIAdem 2019 Resolved Version: DIAdem 2019 SP1 Added: N/A |
|
221454 |
REPORT: DIAdem does not plot bars of height 0 in 2D and 3D axis systems.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2018 Resolved Version: DIAdem 2019 SP1 Added: N/A |
|
902342 |
ANALYSIS: If you apply the "Remove Duplicates" function to a time channel, the result channel is no longer a time channel.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 Resolved Version: DIAdem 2019 SP1 Added: N/A |
|
221374 | 730286 |
REPORT: In 2D tables with the"Auto row height" formatting, DIAdem incorrectly interprets the "Start at row" setting.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2018 Resolved Version: DIAdem 2019 SP1 Added: N/A |
221451 | 740854 |
ANALYSIS: The corridor violations detection algorithm for the ChnCorridorCheck command does not work properly and may cause a crash.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2018 SP1 Resolved Version: DIAdem 2019 SP1 Added: N/A |
221455 | 745522 |
VIEW: The frame zoom creates an incorrect section in the Cascade display if you drag open the frame from the front and left across the axis origin.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 Resolved Version: DIAdem 2019 SP1 Added: N/A |
336425 | 741769 |
DAC: Some variables of the NI-DAQ driver cannot be accessed.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 Resolved Version: DIAdem 2019 SP1 Added: N/A |
336468 | 739200 |
ANALYSIS: When using the functions PulseDetectedRevolution and PulseDetectedRevolutionTime, the last value of the result channel is unusable if the specified number of pulses per revolution is greater than 1.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2018 SP1 Resolved Version: DIAdem 2019 SP1 Added: N/A |
336496 | 740870 |
ANALYSIS: Bit operations do not correctly include the highest bit (bit 31).Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 Resolved Version: DIAdem 2019 SP1 Added: N/A |
336471 | 740747 |
ANALYSIS: The ChnOrderBodeCalc function miscalculates if the time signal contains an offset.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 Resolved Version: DIAdem 2019 SP1 Added: N/A |
336414 | 745312 |
ANALYSIS: Using the ChnDifferentiate function causes a crash if empty channels or channels with a channel length shorter than 2 are used in the function.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 Resolved Version: DIAdem 2019 SP1 Added: N/A |
336428 | 743573 |
ANALYSIS: The ChnEventCreateFilteredTrueChn function does not consider the first value of an event during an inplace operation.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2018 Resolved Version: DIAdem 2019 SP1 Added: N/A |
336479 | 741294 |
ANALYSIS: The ChnResampleFreqBasedXOffsetCalc2 function cannot correctly synchronize certain data sets.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2018 SP1 Resolved Version: DIAdem 2019 SP1 Added: N/A |
336429 | 744983 |
Data Portal: Copying text channels leads to an error if the output channel contains the text "NoValue".Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2017 Resolved Version: DIAdem 2019 SP1 Added: N/A |
336476 |
NAVIGATOR: In the Bus Log Converter, DIAdem does not write special properties of PCAN files to the root.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2017 Resolved Version: DIAdem 2019 SP1 Added: N/A |
|
903229 |
NAVIGATOR: In the Bus Log Converter, J1939 messages sent from all addresses to all other addresses are not processed correctly.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 Resolved Version: DIAdem 2019 SP1 Added: N/A |
|
221472 |
VIEW: Searching for a time value in tables leads to an error.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2018 SP1 Resolved Version: DIAdem 2019 SP1 Added: N/A |
|
452731 |
REPORT: The value of the axis begin and axis end in a 2D axis system may change if you used Cancel to exit the dialog box.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 Resolved Version: DIAdem 2019 SP1 Added: N/A |
|
452725 |
REPORT: The configuration of a REPORT object through a dialog box does not work correctly if VBScript fields are stored in the TagTemporary properties.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 Resolved Version: DIAdem 2019 SP1 Added: N/A |
|
452727 |
REPORT: The text effects of labels in a 2D axis system cannot be used correctly.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 Resolved Version: DIAdem 2019 SP1 Added: N/A |
|
961656 |
REPORT: The height of the y-axes of 2D axis systems with several y-axes cannot be adjusted with the mouse.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 Resolved Version: DIAdem 2020 Added: N/A |
|
944359 |
DAC: Measurements with Ethernet chassis for CompactDAQ no longer work.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 SP1 Resolved Version: DIAdem 2020 Added: N/A |
|
959813 |
VIEW: DIAdem crashes when you change the first value of a specific channel already displayed in VIEW to NOVALUE in a dialog box and then refresh the VIEW display.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 SP1 Resolved Version: DIAdem 2020 Added: N/A |
|
902370 |
NAVIGATOR: A file with the text "%s" in the filename cannot be opened by the DataPlugin Wizard.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 SP1 Resolved Version: DIAdem 2020 Added: N/A |
|
961658 |
REPORT: DIAdem may not display the mini tick grid correctly in 2D axis systems with logarithmic axes.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 SP1 Resolved Version: DIAdem 2020 Added: N/A |
|
956329 |
REPORT: The isolines color in characteristic diagrams is incorrect if the value of the extended isoline is outside the displayed measured values.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 Resolved Version: DIAdem 2020 Added: N/A |
|
957464 |
SCRIPT: If you create a new tab in user dialog boxes, the changed font of the dialog box is not taken into account.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2017 | DIAdem 2018 | DIAdem 2019 Resolved Version: DIAdem 2020 Added: N/A |
|
971958 |
VIEW: The map display does not show a map if you use a cache for the map data.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 Resolved Version: DIAdem 2020 Added: N/A |
|
937971 |
REPORT: Some curve transformations in 2D axis system lead to an error.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 Resolved Version: DIAdem 2020 Added: N/A |
|
962457 |
NAVIGATOR: When the Bus Log Converter converts vector BLF files with CAN-FD formats, signals are missing.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2017 | DIAdem 2018 | DIAdem 2019 Resolved Version: DIAdem 2020 Added: N/A |
|
975367 |
NAVIGATOR: When processing multiplexer frames, the Bus Log Converter may not process shorter frames.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2017 | DIAdem 2018 | DIAdem 2019 Resolved Version: DIAdem 2020 Added: N/A |
|
972583 |
REPORT: Copying and pasting axis systems will interrupt axis synchronization.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 Resolved Version: DIAdem 2020 Added: N/A |
|
901665 |
General: DIAdem does not save in the desktop file whether underscore or tilde is used as separator for the inheritance of properties.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 Resolved Version: DIAdem 2020 Added: N/A |
|
903758 |
REPORT: When you transfer the format of table columns that use a DIAdem expression, variable, or text list, DIAdem also changes the displayed data.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 Resolved Version: DIAdem 2020 Added: N/A |
|
939037 |
SCRIPT: When you call the AddElementList method within the script profiler, DIAdem crashes.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2018 | DIAdem 2019 Resolved Version: DIAdem 2020 Added: N/A |
|
943420 |
NAVIGATOR: The Bus Log Converter may crash when there are ByteArray type signals.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2017 | DIAdem 2018 | DIAdem 2019 Resolved Version: DIAdem 2020 Added: N/A |
|
950039 |
REPORT: The Chart Wizard does not include the channels selected in the Data Portal if you do not access it through the Data Portal.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 Resolved Version: DIAdem 2020 Added: N/A |
|
951880 |
NAVIGATOR: Appended loading using the LoadData method for Navigator does not work if the third parameter has the value Nothing.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2017 | DIAdem 2018 | DIAdem 2019 Resolved Version: DIAdem 2020 Added: N/A |
|
965729 |
SCRIPT: The obsolete function UserVarCompile() changes the variable type and the variable content when called with the "append" parameter.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2017 | DIAdem 2018 | DIAdem 2019 Resolved Version: DIAdem 2020 Added: N/A |
|
974132 |
SCRIPT: After executing the WndShow command, DIAdem may stop displaying error messages when errors occur.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2017 | DIAdem 2018 | DIAdem 2019 Resolved Version: DIAdem 2020 Added: N/A |
|
956900 |
ANALYSIS: The ChnXMSCalc function gives nonsensical results for size-based calculations if the function is called with the "Calculation including all peaks" parameter and the unit of the x-axis is not seconds.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2017 Resolved Version: DIAdem 2020 Added: N/A |
|
965253 |
ANALYSIS: If you use the statistical parameter "Anderson-Darling-Test" (eStatsNormDistB) in "Descriptive Statistics" and save the statistical results in data channels, DIAdem crashes.Workaround: There is currently no known workaround for this issue. |
Reported Version: DIAdem 2019 Resolved Version: DIAdem 2020 Added: N/A |
Installing some patches may require certain additional steps or considerations. Please refer to the following table for more information about patches for this release.
These patches currently do not have any special instructions.