ID | Fixed Issue |
---|---|
699991 | Windows ISC-178x leaks handles while acquiring in VBAI. |
699009 | Copy, Delete, Save, and Paste of steps with resource files can break them. These steps include Pattern Matching, Calculator, Color Matching, etc. |
697456 | Edit unsupported step in Vision Assistant script causes previous steps to disappear. |
692206 | OPC UA client operations take tens of seconds if OPC UA Server has over 1000 items. |
689607 | System Variables are re-initialized to 0 instead of initials values when switching to or from Inspection Mode. |
689261 | Inspection Status is not updated properly when using "Set to FAIL if any previous step fails or if current value of Inspection Status is FAIL" option. |
688609 | VBAI crashes when we try to relearn a calibration axis with an angle set to NaN. |
688278 | Modbus step writes coils at an incorrect address. |
591244 | Calculator step can disable OK button if a control or indicator is copy and then pasted, and the only option is the Cancel the step. |
698675 | TCP steps are not updated after changing the name of the TCP client in the Communication Device Manager. |
698321 | Datalogging step resets the local path control when switching to a different tab and then back to the Destination tab. |
696637 | System Variables are not initialized until the inspection is run on the target. |
695251 | Image Logging step does not log an AVI file correctly when the step also logs other images as well. |
688549 | Modbus Local Registers Terminal does not clear the registers when Edit>>Clear Registers is selected. |
685222 | Detect Texture Defects step can take over a minute to edit for some templates. |
684672 | Read/Write I/O encoder value rolls over prematurely after 32767 counts. |
684668 | Acquire Image (GigE, or USB) step can return a 16-bit image from a camera as an 8-bit when connected to a target and no image was acquired while editing the step. |
678605 | Later versions of VBAI cannot edit calibrations created in VBAI 2013. |
668403 | Vision Assistant Equalize does not work well with 16-bit image. |
668400 | Vision Assistant 16-bit display Mapping does not match VBAI's display mapping. |
663238 | User System Variables get reverted when disconnect from host. |
657236 | Multiple Data Logging steps that log to the same file can return a misleading error "File Format Incompatible". |
648133 | Calculator step can have broken wires if it uses previous results from the same state and that state is copied and pasted. |
646038 | C VBAI API requires VDM run-time to be licensed to be able to call vbaiGetInspectionImageDataDynamic. |
638169 | VBAI API "Get Inspection Image" fails to return an image if a non-default "Image Reduction Factor" is used. |
629493 | VBAI API session gets disconnected from the VBAI Engine if any network connections change. |
619528 | TCP step doesn't include new TCP devices that were defined since the step was last edited. |
701842 | Flat Field Correction step disables the OK button when "Online Correction Using Modeling" is selected. |
701486 | Flat Field Creation Wizard can close immediately in some cases with an error about the image size not being compatible. |
693022 | OPC UA step reports missing device when editing step and OPC UA server is not enabled. |
671311 | State Diagram visible state keeps reverting to the top most state. |
607651 | Calculator step Tool Palette disappears when moving the palette window. |
698176 | OPC UA Server can fail to start when using hundreds of items. |
583905 | When the VBAI SDK is generating code, the All VIs can be broken in some cases. The VI is no longer broken after closing LabVIEW and reopening the VI. |
591243 | Adding a breakpoint in the block diagram of the Calculator step causes block diagram to open with the breakpoint highlighted when running the inspection. |
Vision Builder AI 2018 SP1
ID | Fixed Issue |
---|---|
726819 | When an inspection saved in Vision Builder AI 2014 is opened twice in a row, Calculator steps might return fail. |
726371 | Vision Builder AI might crash when running inspections including a Count Pixel step operating a very large ROI partially outside of the image. |
722893 | Vision Builder AI crashes when editing a Vision Assistant step. |
716059 | Reading the value of Custom Inspection Interface controls returns Measurement Not Available. |
713213 | Learning a pattern matching template fails after using the "Auto Crop" button. |
706164 | Vision Builder AI's web server fails to start on RT targets. |
703116 | Inspections including Map Defect steps fail to load on RT targets. |
726078 | Editing a Track Objects step returns a "Region of interest not valid" error. |
726029 | .Flat Field Wizard fails to warn when trying to use a flat field image name that already exists. |
724123 | Vision Builder AI 2018 does not load correctly certain inspections last saved with a previous version. |
717930 | Pattern matching steps might return different results when editing the step vs. running the step in an inspection. |
716661 | Vision Builder AI cannot edit older calibration files. |
714764 | When configuring an Industrial Controller, video settings are not valid if a monitor is not connected. |
714278 | When configuring a Pattern Matching or Map Defects step, editing a template resets the presets to the default values. |
714277 | When using a Pattern Matching step, switching the algorithm from Low Discrepancy to Value Pyramid significantly increases the template size. |
714041 | The calibration origin might be reset to (0,0) when editing a calibration file. |
713025 | The Windows taskbar hides the bottom portion of the Vision Builder AI window when maximized on a secondary monitor. |
712602 | Fonts used on the inspection interface displayed on an RT target are incorrect. |
708749 | When running an inspection, image acquisition steps do no re-initialize cameras that are disconnected and reconnected. |
708631 | When editing a very large Vision Assistant script, steps at the end of the script are sometimes not selectable. |
708151 | Camera configuration cannot be modified in image acquisition steps when the same camera is also used in the Select Inspection state. |
706337 | Run buttons might remain disabled after using the Run once button. |
705501 | Select Inspection State does not switch between inspections when using previous measurements. |
703633 | DAQmx step does not work on RT target after performing a custom software installation using MAX. |
703241 | Converting inspection to LabVIEW returns incorrect code for Map Defect steps. |
702135 | Flat Field creation wizard allows a Model image to have a different size than the acquired image, which then shows as "Image Not Available" after moving through the wizard and trying to select it as the field image. |
668403 | The Equalize function in a Vision Assistant step returns incorrect results for 16-bit images. |
725973 | Line Fit Deviation test in the Geometry Step always returns a "Fail" in VBAI. |