The following items are the Bug Fixes in the NI-Digital Pattern Driver 18.0.
ID | Legacy ID | Fixed Issue | Issue Details |
---|---|---|---|
692863 |
| The NI-Digital driver is not installing policy files that redirect between major/minor versions when using the .NET API. | The lack of policy files means that code built against an older version of NI-Digital will have to be recompiled before it can be used on a system that only has the newer version. |
681944 |
| Certain programming sequences can result in internal bus contention that, over time, could damage the instrument. | Contention can occur after using source memory on the PXIe-6570 internal bus. Over time this can cause damage to the instrument. |
696854 |
| There is an intermittent 10 ns delay seen between synchronized digital pattern instruments when using NI-TClk. | When using NI-TClk with the Timing Absolute Delay Enabled property set to FALSE, there is an intermittent 10 ns delay seen between synchronized digital pattern instruments. The Timing Absolute Delay Enabled property is set to FALSE by default. |