The following items are the IDs and titles of a subset of issues fixed in NI Sound and Vibration 2014.
Fixed bugs observed in LabVIEW-based Sound and Vibration VIs.
ID | Fixed Issue |
416096 | Extract Single Tone (Complex) Returns Inconsistent Frequency if Advanced Span is Set to A Very Wide Value |
418311 | Ball Spin Frequency is Calculated Incorrectly in SVT Rolling-Element Bearing.vi |
421114 | In UFF 58, Record 9: Ordinate Data Characteristics are written incorrectly for acceleration channels. Instead of 'Acceleration', 'Time' is written to Fields 1 and 5. |
421699 | Spectrum with Cursors XControl Always Displays Hanning Window |
454083 | AC and DC levels returned incorrectly for spectrum instance of AC & DC Levels VI when window size not equal to FFT size |
452678 | SVT Third-octave Analysis Function Returns NaN for Certain Sample Sizes |
Fixed bugs observed in Sound and Vibration Assistant.
ID | Fixed Issue |
401838 | SVA Crashes on Loading Project After Closing Example Project |