Each issue appears as a row in the table and includes the following fields:
ID | Known Issue | |||||
---|---|---|---|---|---|---|
369497 | Incorrect behavior occurs when you load an I/Q file with invalid arguments Loading an I/Q text file with an incorrect array type may force the NI-RFSG SFP to close the current device session or cause the RF On/Off button to stay ON as the NI-RFSG SFP returns an error. If you click the RF On/Off button, the error is removed, but no output signal is generated. Workaround: Reopen the session if needed, then load the I/Q file, or disable Arb mode to generate a signal at the output.
| |||||
372625 | NI-RFSG SFP does not clear PLL lock errors When disconnecting an external Reference Clock, the NI-RFSG SFP returns an error. When you reconnect an external Reference Clock, you must change a setting on the NI-RFSG SFP, such as the frequency setting, in order for the NI-RFSG SFP to attempt to sync to the Reference Clock. Workaround: N/A
| |||||
450527 | An error occurs when you re-enable Arb mode after saving the NI-RFSG SFP configuration When the NI-RFSG SFP is generating in Arb mode and you save the configuration, disabling and then re-enabling Arb mode returns an error. The NI-RFSG SFP continues to generate a signal as if Arb mode is disabled. Workaround: Reload the I/Q file to clear the error, or toggle the RF On/Off button to clear the error.
|
Related Topics:
Contact NI regarding this document or issues in the document. If you contact NI in regards to a specific issue, reference the ID number given in the document. The ID number contains the current issue ID number as well as the legacy ID number (use the current ID number when contacting NI). You can contact us through any of the normal support channels including phone, email, or the discussion forums. Visit the NI Website to contact us. Also contact us if you find a workaround for an issue that is not listed in the document.