ID | Known Issue |
---|
644978
| Code using API in niFgenObsolete.llbs and converted for LabVIEW NXG is broken
Workaround: N/A
Reported Version: 17.0 | | Resolved Version: N/A | | Added: 05/09/2017 |
|
480531
| Windows 8.0 to Windows 8.1 upgrade issue
Upgrading the version of Windows on a system with this driver installed may result in the loss of device names, the loss of device configuration, and/or devices appearing disconnected.
Workaround: N/A
Reported Version: 14.0 | | Resolved Version: N/A | | Added: 07/08/2014 |
|
251164
| A protocol violation error occurs when using an PXIe-1075 chassis
When routing triggers across segments on the PXIe-1075 chassis, a protocol violation error may occur. The PXIe-1075 has three bus segments: slots 1 through 6, slots 7 through 12, and slots 13 through 18. If the devices are located in different segments, this issue may occur. Some features, such as NI-TClk, when used for synchronization applications, internally route triggers.
Workaround: N/A
Reported Version: 2.8 | | Resolved Version: N/A | | Added: 10/24/2011 |
|
192435
| NI-FGEN devices are unable to start after installing NI-FGEN 2.7 or later in addition to NI-DAQmx 7.0 or 7.1
After installing NI-FGEN 2.7 or later on a system with NI-DAQmx 7.0 or 7.1 already installed, NI-FGEN may return an error about NI-FGEN devices unable to start.
Workaround: After installing NI-FGEN 2.7 or later, reboot, and then repair NI-FGEN using the Microsoft Windows Control Panel.
Reported Version: 2.7 | | Resolved Version: N/A | | Added: 10/24/2011 |
|
N/A
| Installation interrupted by security dialog boxes
When you run setup.exe to install the software from the DVD, you are prompted to choose whether you want to always trust software from National Instruments. If you do not select this option, your installation may be interrupted by one or more Microsoft Windows security dialog boxes. However, if you run the installer in silent mode from the command line, you do not receive this prompt, and the installer automatically installs NI's Software Publisher Certificate to your Windows Trusted Publisher Store. If you do not want to make this change to your Windows Trusted Publisher Store, do not choose this installation method.
Workaround: N/A
Reported Version: 2.4.5 | | Resolved Version: N/A | | Added: 10/24/2011 |
|
88974
| NI-FGEN function documentation does not launch from NI TestStand
After attaching an NI-FGEN function to a test step in NI TestStand, selecting the help icon does not launch the NI-FGEN help documentation.
Workaround: N/A
Reported Version: 14.0 | | Resolved Version: N/A | | Added: 04/17/2014 |
|