LabWindows™/CVI™ 2017 Known Issues

Overview

This document contains the LabWindows/CVI 2017 known issues that were discovered before and since the release of LabWindows/CVI 2017. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.

 

Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community.

 

Each known issue includes these fields:

  • Issue ID
  • Legacy ID - The issue's legacy ID from NI's deprecated bug reporting database (if applicable)
  • Issue Title
  • Problem Description
  • Workaround
  • Reported Version - the earliest version of LabWindows/CVI the issue was reported in
  • Resolved Version - version the issue was resolved or was no longer applicable
  • Date Added - the date the issue was added to the document (not the reported date)

 

Modules and Toolkits

The Known Issues for toolkits and modules can be found in the LabWindows/CVI Modules and Toolkits Known Issues document.

 

Document Organization

The Known Issues Document is divided into two separate tables appearing in two separate documents. The known issues in this document are organized by the category of issue, and sorted by the date the issue was added to the document. To view the issues organized by date, visit the document linked below:

Known Issues by Date

 

Contacting NI

You can contact us through any of the normal support channels including phone, email, or the discussion forums. If you are contacting NI in regards to a specific issue, be sure to reference the ID number given in the document to the NI representative.

Known Issues by Category

The following items are known issues in LabWindows/CVI 2017 sorted by Category.

.NET and ActiveX
44669The WordRpt_SetHeader function might not always work as expected.
284293Using a WebBrowser ActiveX control from a thread created in a LabWindows/CVI thread pool leaks memory.
348295A panel containing an ActiveX control disappears when the mouse hovers over the control if the titlebar is not visible.
148778The ActiveX Controller Wizard does not support LONGLONG and ULONGLONG data types.
363992The first letter of exported functions in type libraries has inconsistent case behavior.
426545Creating an ActiveX Controller for a large type library, such as the Microsoft HTML Object Library, results in the message Maximum number of function tree nodes exceeded.
Analysis
306163The PeakDetector function does not recognize peaks of a sine wave when the sampling rate is very high.
Compiler
237998Cannot link some uuid.lib symbols in a 32-bit program.
291945Compiling a very large array in debug mode can be very slow.
335405Cannot link some odbccp32.lib symbols in a 32-bit program.
457821Including datasize.h and windows.h causes a typedef redefinition with different types error for the INT8 type definition.
412591Building a project that has a long file path causes LabWindows/CVI to crash.
422103Some large source files take much longer to compile in LabWindows/CVI 2013.
424254Calling the assert macro generates a warning that code will never be executed when the LabWindows/CVI compiler can determine the outcome of the expression.
430785Compiling causes an error: definition of the macro '_TARGET_FILE_VERSION_' conflicts with the definition used to build the precompiled header message.
471567Generating HTML help from source with array pointer type parameters results in an 'unknown' type generated in the help.
505265The FileExists function may fail in projects that use the Vision Builder AI engine.
516928Including a library (.lib), possibly of an old format, in both the project tree and the LoadExternalModule (LEM) Options dialog causes the following error: error: Input file is not a valid archive.
357424Casting an int to a union does not cause a compile error.
412828Building a distribution kit with a long file name can cause LabWindows/CVI to crash on Windows XP.
430409The compiler may report the build error The compiler has run out of memory if <filename>.obj.cvidefprots exceeds 260 characters.
434676Compiling large source files or functions may cause the compiler to display the following build error: The compiler has run out of memory.
438833Incorrectly configured compiler define causes build error: <command line>:28:9: error: macro names must be identifiers.
447401Compiler Defines return compile errors when porting code from LabWindows/CVI 2009 to LabWindows/CVI 2010.
475889GetExternalModuleAddr does not work for stdcall functions in import libraries created with Microsoft Visual Studio.
511542No access violation is thrown when trying to modify constant strings which are assigned to variables.
515817Generating help from source is incorrect on a multibyte OS if the source code tags or file name contains multibyte characters.
543008The compiler incorrectly issues an uninitialized warning when a locally defined pointer to a structure is followed by a structure definition.
564085The build for a DLL target does not detect mismatches between header declaration and function definition when exporting symbols from an include file.
566083Old-style function definitions preceded by a prototype are diagnosed with the strict prototypes warning.
583937There are compile errors in the Interactive Window when including windows.h and winnt.h after compiling with only winnt.h included.
586821Selecting Compile with precompiled include file in Build Options causes Assertion Error in Windows Event Viewer.
588349A Compile error is thrown in the interactive window when calling the alloca() function.
591193When run-time checking is enabled, the first element of a multidimensional array of structures is initialized to NULL.
555561The Options»Build Options»Require function prototypes option does not issue compile errors when function declarations are not declared using a full prototype.
706577Casting a double variable to a float produces unexpected results if compiled in 64-bit release mode with no optimizations.
Debugging
210086The LabWindows/CVI environment may hang while debugging with the Variables or Watch windows open.
335983Tooltip for symbol values during debugging may appear on top of the editor's scrollbar.
346034#define macros cannot be monitored in the Watch window.
370682When the cvidebug.exe process dies or is intentionally stopped, LabWindows/CVI cannot debug again until it has been restarted.
423739The DefineThreadSafeVar macro produces a warning indicating it will never be executed.
438870Using the debugger to change the value of one variable in an anonymous nested structure changes it for all the variables in the structure with that name.
438896LabWindows/CVI does not display a warning message when both a main and a WinMain entry point are defined in a source file.
442184Interface to Win32 API functions cannot be run in the Interactive Execution window.
456208The Source Code Browser window displays the same reference to a macro multiple times.
460794The Available Types dialog box in the Watch and Variables and Call Stack windows do not display the full list of types.
460799The Watch and Variables and Call Stack windows display the type incorrectly after using the Interpret As option multiple times.
461757The Break On Change state of a watch expression is lost when stopping and restarting execution or unloading and reloading a workspace.
464146Setting a breakpoint from Breakpoints dialog box on an invalid line while debugging an application causes uncommitted changes in the dialog box to irreversibly take effect.
464507Running the Interactive Execution window a second time after finishing a run of the interactive statements with the Finish Function option causes the Interactive Execution window to crash.
464904The Watch and Variables and Call Stack windows do not mark the item for a pointer to a variable as red if the variable value changes.
430376The Variables and Call Stack, Watch, and Array Display windows do not show the contents of char arrays with more than 252 unprintable characters.
434406LabWindows/CVI no longer displays a warning while debugging a real-time application if threads are still running on the target when RTmain exits.
437356Stepping over a function call located at the last line in the enclosing lexical scope causes a Step Into instead of a Step Over.
438839LabWindows/CVI displays incorrect or no values for CmtThreadLockHandle and CmtTSQHandle variables when the variables are declared as int.
443138The Interactive Execution window does not allow immediate termination when execution is suspended due to a break on change on variable value.
447051If the LabWindows/CVI debugger crashes (cvidebug.exe), all of the entries from the Watch window are cleared. Once you begin a new debugging session, the entries are restored to the Watch window.
460394The Resource Tracking window shows freed resources as allocated if resource tracking is disabled after allocation.
463635Opening the Graphical Array View for large, dynamically allocated arrays from the Array Display window causes an Index passed is out of range error.
464563LabWindows/CVI does not allow you to attach to a 64-bit process running on a remote system.
466209The DebugPrintf function truncates large strings when printing to the Debug Output window.
466763LabWindows/CVI does not show enough digits of precision in tooltips or the Variables and Call Stack window.
466921Running a function using its function panel results in an Interactive Execution Unresolved symbol error even if the Include loaded instrument drivers in Interactive window Environment dialog box option is enabled.
469910LabWindows/CVI hangs when stepping through code for a console application and choosing Set Next Statement on the previous line after closing the console window while suspended.
470486The Interactive Execution window incorrectly excludes the line and offsets the execution highlighting when adding a variable declaration on an instruction line.
470948The Interactive Execution window does not allow stepping into the main function of a project.
472987The Parameter type incompatible with format specifier non-fatal run-time error does not display source location when 64-bit variables are used in code that causes the run-time error in the Debug64 configuration.
502946The LabWindows/CVI debugger does not recognize variables that include the $ symbol as part of the variable name.
465367If the data slice in an Array Display is changed, the numeric controls, Row and Column, in the Go to Cell dialog correctly change their ranges, but Go to Cell does not go to the correct cell.
470673Changing the data slice and displaying the format of a 2D char array causes the Array View to become unusable, if the first dimension of the array is bigger than the second.
472358Terminating execution while the Watch window is closed causes watch expressions to be duplicated.
473458The Variables and Call Stack window occasionally shows ERROR: Unexpected character. when changing the specific type for a variable.
477649An incorrect uninitalized variable non-fatal run-time error is generated for partially initialized arrays inside of structs.
478665A Graph doesn't have that many cursors error appears when debugging an application with multiple arrays shown in the Graphical Array View.
479326The tooltip for an empty field on a function panel displays an = ERROR: Unexpected end of input. error when execution is suspended during debug.
487428You receive a non-fatal run-time error, Attempt to read beyond end of string, when specifying a string member of a struct returned by a function as the source input for sprintf.
503717Debugging a project while concurrently debugging statements in the Interactive Execution window causes LabWindows/CVI to stop responding to commands.
504099A linker error will occur if a global variable is referenced in the Interactive Execution window and if the project which defines the global variable is being debugged.
515028When trying to browse for the members of a structure () inside the Watch window, no browse info is found.
515433When a compilation error occurs while running a function panel interactively, information about which function panel field caused the compilation error is not shown.
515436When using a user-interactive function (e.g., printf) in the Interactive Execution window, the console is not closed when execution finishes.
515499Active breakpoints in the Interactive Execution window are hit when running function panels interactively.
515639An uninitialized pointer in a structure cannot be modified in the Variables and Call Stack and Watch windows. In the Watch window the pointer has the value Uninitialized.
519172If you try to stop a program running in the Interactive Execution window after the cvidebug.exe process has been terminated, the editor crashes.
533817The editable data tooltip does not display characters after a newline character.
438921The Variables, Call Stack, and Watch windows display incorrect indices for multidimensional arrays with one dimension of size one.
439442Compilation errors in the Interactive Execution window do not correctly specify the error location.
439443The Interactive Execution window displays error dialogs when run with empty contents after pressing Edit»Clear Window.
439990The Interactive Execution window does not honor disabling Break on»First Chance Exceptions or executing SetBreakOnFirstChanceExceptions (0);.
44219864-bit addresses are truncated in the GetExternalModuleAddrEx and GetExternalModuleAddr Function Panels.
449641Details are not displayed when loading an invalid file in the Resource Tracking window.
449642Loading a corrupted file into the Resource Tracking window can crash LabWindows/CVI.
450318When an Interactive Execution contains an unclosed brace the code does not execute and an error is not generated.
453270Graphical Array View does not work for 2D arrays with a dimension of size one.
456818If a function contains a function declaration, the Source Code Browser incorrectly lists the declared function in the Called from view pane of a function called after the declaration.
463300Interactive Executions only display errors from included header files the first time they are built.
463922If there are expanded items in a Watch window after running an Interactive Execution, opening a different project displays the dialog There are no items in the list control.
464227Editing the value of a variable in a Watch window displays Value illegal or out of range after running an Interactive Execution.
473970Object files that use CVI library functions do not produce user protection errors when called from LoadExternalModule.
478903In the Variables and Call Stack window, the "[Frames below may be incorrect or incomplete.] entry disrupts navigation with the Up Call Stack and Down Call Stack buttons on the toolbar.
482391When running an Interactive Execution while not suspended on a valid steppoint, CVI incorrectly reports "LabWindows/CVI could not launch the interactive window. Please repair your installation of LabWindows/CVI".
510665View Variable Value only shows the first element of char* variables in the Array Display when the char* variable value is set using CA_BSTRGetCString.
515795Red highlighted text in the Memory window is not always reset after every execution.
515797Editing a value in the Memory window does not highlight that value in red when using the Memory window for the first time after opening a project.
541876Watch expressions that are offset from a declared symbol's address are not editable.
553889The Watch window shows the global variable address rather than the thread-local address for variables that use the __thread storage class.
568788The Type of character arrays does not update in watch expressions when you perform pointer arithmetic on them.
570889Accessing an array element of a pointer to an incomplete structure that is dynamically allocated as an array of fixed structures causes a Dereference of out-of-bounds pointer user protection debugging error.
580336LabWindows/CVI displays an error that reads Another debugging process is already in progress when the Attach to Process dialog is opened after running statements in the Interactive Execution window.
591529After changing the type of a local variable using the Interpret As option from the Variables and Call Stack window, the displayed type is incorrect.
591577The debugger highlights all expressions in a multi-variable declaration block broken over multiple lines rather than highlighting individual declarations.
396028The LabWindows/CVI 2013 and newer debugger is slower than LabWindows/CVI 2012.
525073LabWindows/CVI may slow down or hang when performing extended debugging with the Resource Tracking window.
Development Environment
189843The Perforce 2009.1 client may cause LabWindows/CVI 2009 to crash.
193733Launching the DataSocket Binding dialog box may cause LabWindows/CVI to hang on Windows 7.
216549LabWindows/CVI installs KeyHelp.ocx, which contains a security vulnerability.
227324LabWindows/CVI cannot copy files to the VXIPnP directories on Windows Vista and later.
289314User-defined types always receive an asterisk when used as output types in function panels.
308191A multi-project workspace with projects targeting both 32-bit and 64-bit can incorrectly display import libraries.
329035LabWindows/CVI Conversion Wizard does not transfer 'Compile with precompiled include file' setting to 'Precompiled Headers' setting in Microsoft Visual Studio.
332047LabWindows/CVI stops responding while searching for an inaccessible network location.
322905Files in a project may not display source control icons when a LabWindows/CVI project is associated with the Perforce client.
333837LabWindows/CVI projects are not handled properly when adding them from new workspaces in instances of LabWindows/CVI created from just-in-time debugging.
334920Corners of Source Editor windows are painted black in non-tabbed Workspace when opened.
357212The save icon does not dim after saving a file.
361958The Project Tree does not auto-hide when a UIR file is opened.
363196Attribute passed is not valid error when declaring a variable in a function panel.
347511Microsoft Visual Studio does not rebuild a LabWindows/CVI project if a UIR file changes but its header file does not.
347986The Load UI resource file dialog box in the User Interface Localizer utility unloads the currently loaded localization.
356708The Source window cursor can persist after selecting text and editing a variable tooltip.
337770Setting LabWindows/CVI to "Run as administrator" will open a new instance of LabWindows/CVI each time you open a file associated with LabWindows/CVI.
333302Auto Backup will provide an error if the file is marked as read-only.
335488Excluded import libraries that represent both 32-bit and 64-bit .lib files are no longer dimmed after switching configurations.
366229The CVIXMLGetNumChildElements function does not count child elements included in an XML entity.
440070The Find Next feature of the Find dialog box does not move to new results on subsequent uses.
390670When you add a line continuation character \ to the end of a comment line initiated by the \\ symbol, the syntax highlighting feature does not continue to the next line, indicating the next line continues the comment.
451665The UI to Code Converter generates code containing an undefined function, InsertCtrlInCtrlArray.
369029The compile process does not wait for user response about missing include statements for header files.
375449Upgrading LabWindows/CVI breaks paths to Clang in .ecc configuration files.
375463File icons may obscure full pathnames in the Project Tree.
383011Unable to close the Open GL plot Properties dialog box after right-clicking the Open GL plot twice while the dialog box is open.
391648Show Completions (<Ctrl-Space>) does not list members in anonymous structures or unions.
403299The Functions in File ring is not wide enough to display some function names.
411386The function panel size changes how function calls are inserted into code.
412464Opening, editing, and saving a source file with a very long file path causes LabWindows/CVI to crash.
429854The Find in Files feature fails when searching all files (*.*) in a directory containing .svn-base files.
437791LabWindows/CVI does not handle edge-specific maximization when restoring from a minimized state.
438547The Functions in File dialog box immediately starts scrolling up when opened.
438733If Hide windows when application is running is enabled, and a run-time crash occurs in the Interactive Execution window, the development environment becomes hidden and cannot be restored.
384832Adding a file that is under source code control (SCC) using the Edit Project dialog box does not mark the file as being under SCC in the Project Tree.
391403Autoscale is a valid option for the y-axis of a strip chart, but the option is missing from the Attribute Browser.
402786Show Completions <Ctrl-Space> does not work if a multi-line string starts with special char like {, }, ;, or #.
408099Pressing <Ctrl-Tab> to switch between tabs causes a Panel, menu bar, or control array handle is invalid message to display if confined function panel windows are open.
409526Macros defined in precompiled headers are not included in browse information.
423818The Show Completions feature fails to display context help for function parameters once the second parameter is highlighted if the function call immediately follows a curly brace.
431732The LabWindows/CVI debugger starts applications outside of the window space in Windows 8.1 if you enable Variable, Continuous Size of Snap Views in Windows and LabWindows/CVI is used in the right-half of the screen.
435479Creating a file with the New»File from Template option that has the same path and name as an existing file results in an out of memory error.
436648Enabling the Compile with precompiled include file option in the Build Options dialog box causes a The User Interface Manager could not be opened to be displayed.
446313A dialog box explaining that saving UIR files will generate new versions of their include files is incorrectly displayed multiple times if there are multiple unsaved UIR files containing custom controls.
463642Watch expressions cannot be deleted by pressing <Delete>, if the Break On Change checkbox has focus.
463873Although Insert Mode is shown as active in the Array Display window when the window displays a data slice, the Insert Mode no longer has any effect.
463921A tooltip containing Invisible is incorrectly displayed in the Memory Display window after maximizing and restoring the window.
467070The Maximum and Minimum fields in the Edit Table Cell dialog box are not wide enough to show int64 values.
467775Enabling LoadExternalModule on one of the default Interface to Win32 API libraries and subsequently removing the library from the project tree causes the Interface to Win32 API library to remain forcibly included.
470691The Build Output window highlights only error rows after double-clicking an error when building with an external compiler for release configuration.
473109Some data types such as _Bool and _Complex are not displayed correctly in function prototype tooltips.
473496Data tooltips have a character entry limit that is about 24 characters at a time.
475321Variables and Call Stack window columns incorrectly display extra columns, and columns are displaced after resizing columns while scrolling.
477231Incorrect confirmation prompts appear when exiting graph or chart dialog boxes.
477287The Options»Preprocess Source File feature truncates output after 1024 characters on a line.
499830Text for Custom Build Actions in the Build Steps dialog box may become corrupted when dialog box is closed.
470220Enabling both the Expand tabs to spaces when saving files and Convert leading spaces to tabs when loading files Editor Preferences options causes the current line statement to be highlighted incorrectly when debugging.
471435Source code completion does not work properly following a / operator.
479810Options»Create Object File does not throw errors if the output object file is read-only.
489731The Variables and Call Stack window will not retain its position when LabWindows/CVI is restarted.
492787"The buffer passed was too small for this operation" error will occur when entering text for a multiline tooltip in the User Interface Editor.
493985Closing the Format and Precision dialog while editing default cell values will cause the Edit Default Cell Values dialog to close.
504102Interactive Execution will create a local copy of global variables instead of using the global variable reference.
509337Distribution Builder may not work properly if the distribution is stored at a network location requiring authentication.
512779The function prototype tooltip will not appear if a struct containing a member with the same name as the function is declared between the function declaration and function definition.
515994When the Control Data Type of a Function Panel is a multi-dimensional array, the Select Variable result list is empty.
519487The source editor tabs are not updated when cycling through files during a Resolve All Excluded Lines operation.
412413LabWindows/CVI crashes when creating new files in path lengths that exceed 260 characters.
412461Browse information is not found after renaming a project using the File»Save <projectname,prj> As command.
412976An output directory at a long path specified in the IVI Instrument Driver Wizard (Tools»IVI Development»Create IVI Specific Driver) can cause LabWindows/CVI to crash.
414649The Scopedem example might return the non-fatal run-time error Attempt to write beyond end of string.
429608A Confirm File Copy dialog box appears when creating a project from template with a long path.
430183LabWindows/CVI cannot open files from paths that contain composed Unicode characters.
430728A Badly formed pathname error may appear when creating a Project from Template (File»New»Project from Template).
430735LabWindows/CVI enters a bad state if you create a new folder in a file dialog launched from LabWindows/CVI but do not commit the new folder name by pressing the <Enter> key.
432769The Debugging Level Build Option is reset to Standard after the Run-time Support Target Setting is changed.
433855Variables declared in macro code blocks are not shown in the Variables tab when browsing a source file using Window»Source Code Browser.
437898Double-clicking an NI DataStore Results Display ActiveX control in the User Interface Editor can cause LabWindows/CVI to crash.
438144UI to Code Converter may generate code that yields a non-fatal run-time error.
438730The Key in the Edit Cell dialog box of a Table control displays the incorrect value after configuring subsequent cell Key values.
438842ATTR_TOOLTIP_HIDE_DELAY is not removed when saving a UIR file for previous versions of LabWindows/CVI.
441568Incorrect East European characters shown after loading a localization file in the Localization tool on a multibyte OS localized in an Eastern European language.
441569The panel title and any tooltips are not displayed with East European characters on a multibyte OS localized in an Eastern European language.
454409Unexcluding a source line is not reflected in the next build unless the change is saved before compiling.
463586Clicking on the ... button to the right of the Network Variable Pathname parameter in the function panel for CNVCreateSubscriber causes a 'The attribute value passed is not valid' error.
464163If a User Interface Resource (.uir) file has been changed, the associated header file will be regenerated when building the project, even if there are no changes required to the header.
488375The Find UI Object (<Ctrl-Shift-U>) feature does not work for controls on tabs which are not being shown.
501555The View » Include File menu item opens ansi_c.h instead of lowlvlio.h for all Low-Level IO function panels.
504121No prototype is displayed while cursor is on a function pointer parameter.
533828Variables Window shows two entries for a redefined variable.
543053Some macros are listed twice in Predefined Macros dialog.
543055The predefined macros in the Build Options dialog lists macros for previously selected configuration when All Configurations is selected in Configuration ring.
555915The Information Status of the UI editor does not always show the selected control.
562270The ADE generates incorrect browse information for a local function call if the function call result is cast using function pointer cast.
564083The "glue code" for DLL functions generated by the Generate DLL Import Source feature does not have calling convention specified.
568823CVI_AppSetSelection allows for selecting half characters on multibyte operating systems.
570567The LabWindows/CVI ADE Distribution Installer Version Maximum version is 254.254.65534 instead of 255.255.65535
574521The LabWindows/CVI ADE hangs when attempting to print and there are at least two printers, one of which has a Unicode symbol in its name, that doesn't have ANSI equivalent.
579855The Edit»Insert Construct»Function Documentation Tags feature does not generate documentation tags past a parameter that is a function pointer.
587239The graphical array view for arrays with 3 dimensions or more throws an exception.
588343Samples that use assert_unreachable fail to compile from Visual Studio.
589439The Go to Definition function does not always store the initial cursor location.
589445The Go to Definition menu item takes you to the incorrect location.
589452CVI crashes when building a project if a Function Panel is present in the opened file section of the workspace file and the same Function Panel is loaded in the user libraries.
592761The project appears to be modified after opening and closing the Manage Configurations dialog.
595232The UI Editor displays a The index passed is out of range error when cutting the last item in a menu bar.
533835The name of the exe is not changed on 64-bit configurations when renaming the project.
537281Revert Tab command moves cursor but not text for a single line.
584096The Properties dialog of OpenGL plot cannot be closed after right-clicking on the plot when Properties dialog is already open.
586870Resource Tracking does not work properly when using Specify Executable and Command Line option.
588402An Internal error is thrown when using a distribution file with an unrecognized minimum .NET version.
588406The SaveBitmapToTIFFile incorrectly returns Out of memory when destination file not found.
382558Opening a newer UIR file in a previous version of LabWindows/CVI and saving it can corrupt the UIR File.
383362Sometimes when extern is used in a variable declaration, Go to Definition highlights the declaration instead of the definition.
388664Using Show Completions on a function that doesn't exist may result in other functions no longer appearing in the Show Completions list.
399762Include statements dialog incorrectly adds include statements to multi-line comments.
404335LabWindows/CVI may show an incorrect function prototype if it cannot resolve types in that function prototype
408446Arrays of pointer type in function panels may not be recognized as arrays.
525255Browse Information is not generated after editing an ActiveX Server from the Edit ActiveX Server Wizard.
Hardware
296666Regenerating DAQmx example code can sometimes fail to regenerate code.
Installer
128084Uninstalling LabWindows/CVI from Windows Vista does not completely remove context menu file associations.
309196Uninstalling LabWindows/CVI or a distribution containing the LabWindows/CVI Side-By-Side Run-Time Engine does not remove some components from the Windows side-by-side directory.
Linux
162307Cannot set the active tab page after deleting a tab.
Performance
144640LabWindows/CVI MAX_PATHNAME_LEN is more restrictive than Windows ANSI path limitation in multibyte systems.
176800LabWindows/CVI projects converted to Microsoft Visual C++ 2005 projects fail to build because of link errors.
41414A small memory leak exists in network variable creation.
256901Passing a pointer to a custom data type to a function that takes a void * will leak memory in a debug build.
281013Calling DDC_SaveFile often while creating a TDMS file using the TDM C DLL or the DDC Library can result in errors.
257029The LabWindows/CVI Run-Time Engine creates windows in its DLL_PROCESS_ATTACH handler.
457464Passing a bitmap file containing negative heights to PlotBitmap or GetBitmapFromFile causes a non-fatal run-time error: Library function error (return value == -12 [0xfffffff4]). Out of memory.
460818SMTP servers reject email from InetSendMail because it does not send date information in the header.
371953The intensity plot does not handle NaN values.
405988Changing the active table cell can incorrectly send the EVENT_ACTIVE_CELL_CHANGE event multiple times.
408097Passing a scalar value as the mask parameter of PlotPackedDigitalLines causes a general protection fault.
424944Creating a .NET controller for a large assembly, such as Microsoft.mshtml, appears to cause a hang but eventually completes successfully.
429320InetFTPGetDirList returns 0 on certain FTP servers despite the presence of files.
382850The NIReport_Print function hangs on Windows 8 when you select Microsoft XPS Document Writer as the printer.
511573Scrolling through a table control containing thousands of images may cause a General Protection Fault.
417963The compiler crashes when compiling a file that contains assembler instructions with C expression operands.
579557The LabWindows/CVI Runtime does not support callback function names containing dollar ($) signs.
593193The Translate From Dictionary feature of the User Interface Localizer Tool fails to translate all items in a UIR file containing a large number of subpanels.
Stand-Alone Applications and Distributions
186565LabWindows/CVI distributions cannot install fonts on Windows Vista or Windows 7.
309112LabWindows/CVI 8.0 distributions cannot include the ActiveX container merge module if LabWindows/CVI 2009 or later is installed on the same system.
354481User specified icons are not displayed in Windows Explorer for larger sizes in Windows Vista/7.
440951When building a 64-bit installer, there is no installation directory option for LabVIEW (64-bit).
442334Application hangs may occur when panning a graph outside the double data range.
442335Application hangs may occur when zooming a graph with log scale outside the double data range.
User Interface
126708PlotArc lacks accuracy for drawing a small angle with a large radius.
140926Changing the axis range on a LabWindows/CVI graph plot with few points causes skewed plot lines.
193088If a LabWindows/CVI popup panel is not active, subsequent popup panels may appear behind the original popup panel.
193403The panel attribute ATTR_MOVABLE does not work with Aero enabled on Windows 7/Vista.
194450LabWindows/CVI windows do not support Aero Shake.
209745Very large maximum stack sizes cause the "My Documents" button of LabWindows/CVI file select popup panels to fail.
303637Scrolling strip charts can have inaccurate values for min and max due to rounding errors.
293672Some user interface controls do not draw Windows styles on mouse-over.
292070Passing TRUE to the RestrictDirectory parameter of FileSelectPopup does not completely restrict the directory to the initial directory.
37666Panels displayed with ATTR_WINDOW_ZOOM set to VAL_MAXIMIZE will not restore after showing the desktop.
314106The x-axis of the digital graph displays improper divisions.
316397Saving a file with the FileSelectPopup function displays a "file already exists" error when another file with the same basename and no extension exists in the selected directory.
329405Numeric control radix does not resize with control text size.
335982MultiFileSelectPopupEx cannot select multiple files if the first file in the list does not exist and the second file does.
351981Dimming ActiveX control does not terminate mouse tracking.
337950Graph zoom selection box leaves artifacts if a control is moved over the drawing region in between frames.
347056Dragging the ring tank control value to change its fluid height at run-time may cause black lines to appear where the previous fluid height was.
349832The mouse wheel scrolls the wrong control while ring control menu is displayed.
350412In some cases, the EVENT_LOST_FOCUS and EVENT_COMMIT events are not displayed in Operate mode when changing focus away from controls.
350752A tree item tooltip continues to display when the cursor is over a tree item and another active window is in front of part of the tree item.
350944The numeric control cannot have a transparent background.
241929Ctrl-Tab and Ctrl-Alt-Tab on Tab Control does not generate an EVENT_KEYPRESS event if another control has focus.
413695Radial controls do not resize all elements proportionally.
369944The canvas control creates some undesired artifacts when rotated or moved around.
382278The save button cannot be used in the Attribute Browser toolbar.
404129After rotating the markers of a gauge control, the needle becomes misaligned with the center of the gauge.
421591Active tooltips do not update when the tooltip text changes programmatically.
423072The two panel attributes, ATTR_HEIGHT and ATTR_WIDTH, cannot be sized beyond a certain value, which depends on monitor resolution.
427065The maximum window size is limited by screen resolution.
431566In the User Interface Editor, if you rotate a text message that has the Size to text option disabled, the resulting text message is drawn incorrectly, selected incorrectly, and inoperable.
432165Under specific graph setting conditions, the fat line plot style renders incorrectly.
437605Graphs containing multiple plots with different plot styles show incorrect plot styles in the graph legend.
439046Toolbar click events do not cause numeric controls to leave edit mode.
460638The picture command button can incorrectly show the resizing frame when the Size control to image Fit mode is selected.
391647Changing focus from the graph control while you operate a cursor inside the control leaves the cursor at an intermediate position.
402602The graph control plot can change size when the graph control changes size, even when the Fixed Plot Area attribute (ATTR_FIXED_PLOT_AREA) is enabled.
424549The default values for the ATTR_HIDE_HILITE and ATTR_HILITE_ONLY_WHEN_PANEL_ACTIVE attributes do not persist for table controls when set in the UIR file.
461922Enabling Show Grid and Auto Divisions in the Edit Axis Settings dialog box for the right y-axis causes incorrect x-axis tick marks to appear.
470189Resizing a knob control by operating a splitter control causes the digital display of the knob control to be positioned at the wrong coordinates.
484206The image quality of some images loaded in a picture command button degrades after saving and loading the user interface file multiple times.
489628Displaying a floating point number with more than 16 digits may cause the number to be displayed in scientific notation.
494678EVENT_COMMIT is not raised when focus is changed from a table cell in edit mode to a different user interface panel.
498977Graph axis divisions may not be plotted when axis scale is set to certain values.
514898LabWindows/CVI does not mark the UIR file as modified after changing the Frame Color of a decoration, which results in changing the Conform to System Color and Conform to System Theme panel attributes.
526939You cannot directly change the tab order of initially dimmed controls in the Edit Tabbing Order dialog by clicking the dimmed controls.
415857The table attribute ATTR_FIRST_VISIBLE_ROW does not work in some cases.
438150A previously selected control may retain focus after subsequently attempting to operate a Ring control.
440980When zooming a graph with log scale on the y-axis, the y-axis label displays too many decimal digits.
545203When a user interface application uses SetMouseCursor to set the mouse style to VAL_POINTING_FINGER_CURSOR, and the panel contains a HyperLink Toolslib custom control, the custom control issues a 'The mouse cursor passed is not valid' library function error.
556606Tooltips can be clipped by bottom edge of monitor.
590484The Strip Chart axis label angle changes when the panel is resized.

Known Issues

IDKnown Issue
.NET and ActiveX
44669

Return
The WordRpt_SetHeader function might not always work as expected.
Embedding pictures in a header does not work.

Workaround: N/A

Reported Version: 8.5  Resolved Version: N/A  Added: 11/22/2010
284293

Return
Using a WebBrowser ActiveX control from a thread created in a LabWindows/CVI thread pool leaks memory.
Threads from a LabWindows/CVI thread pool, run using CmtScheduleThreadPoolFunction, will leak memory if they host a panel that displays a WebBrowser ActiveX control.

Workaround: N/A

Reported Version: 2009  Resolved Version: N/A  Added: 03/08/2011
348295

Return
A panel containing an ActiveX control disappears when the mouse hovers over the control if the titlebar is not visible.

Workaround: If the control has a windowless mode, use the windowless mode.

Reported Version: 2009  Resolved Version: N/A  Added: 07/22/2012
148778

Return
The ActiveX Controller Wizard does not support LONGLONG and ULONGLONG data types.

Workaround: Add the methods containing int64 parameters manually to the generated files.

Reported Version: 9.0  Resolved Version: N/A  Added: 08/22/2014
363992

Return
The first letter of exported functions in type libraries has inconsistent case behavior.

Workaround: N/A

Reported Version: 7.1  Resolved Version: N/A  Added: 08/22/2014
426545

Return
Creating an ActiveX Controller for a large type library, such as the Microsoft HTML Object Library, results in the message Maximum number of function tree nodes exceeded.
LabWindows/CVI is unresponsive while the ActiveX Controller Wizard generates the code, and the message appears after some time.

Workaround: Two ways to reduce the number of function panels:
  •  
  • In the ActiveX Controller Advanced Options dialog box you can deselect objects that you will not use.
  •  
  • On the Configure panel you can select Compatibility Options and change the Property Access Functions option to either Per Object or Per Server to significantly reduce the number of function panels used. Selecting either of these options might make it more difficult to access properties but all objects are still available.
  •  


Reported Version: 8.0  Resolved Version: N/A  Added: 08/22/2014
Analysis
306163

Return
The PeakDetector function does not recognize peaks of a sine wave when the sampling rate is very high.
If the peak is relatively flat because of the high number of points acquired at the high sampling rate, the PeakDetector function may not find the peaks.

Workaround: N/A

Reported Version: 2010  Resolved Version: N/A  Added: 07/27/2011
Compiler
237998

Return
Cannot link some uuid.lib symbols in a 32-bit program.

Workaround: N/A

Reported Version: 9.0  Resolved Version: N/A  Added: 11/22/2010
291945

Return
Compiling a very large array in debug mode can be very slow.
For instance, compilation of the following code in debug mode would be very slow:



char *bigarray[30][25][1000][100];

int main (int argc, char *argv[]) { return 0; }



Workaround: Change the Debugging level option (Options»Build Options) to No run-time checking.

Reported Version: 2010  Resolved Version: N/A  Added: 08/02/2011
335405

Return
Cannot link some odbccp32.lib symbols in a 32-bit program.
The issue exists with the odbccp32.lib that is included in the Windows 7 SDK.

Workaround: Use odbccp32.lib from the Windows Vista SDK instead.

Reported Version: 2010  Resolved Version: N/A  Added: 07/17/2012
457821

Return
Including datasize.h and windows.h causes a typedef redefinition with different types error for the INT8 type definition.

Workaround: Modify datasize.h by commenting out the following line:



typedef char INT8;, which is line 104 by default.

Reported Version: 2013  Resolved Version: N/A  Added: 03/28/2014
412591

Return
Building a project that has a long file path causes LabWindows/CVI to crash.
Previous versions of LabWindows/CVI display a Filename is too long message instead of crashing.

Workaround: N/A

Reported Version: 2010  Resolved Version: N/A  Added: 05/07/2014
422103

Return
Some large source files take much longer to compile in LabWindows/CVI 2013.
The following is true of the new LabWindows/CVI 2013 compiler:
  •  
  • Single-file compilation is slower in 2013, regardless of what comprises the code.
  •  
  • Multi-file compilation is faster in 2013 because of concurrent compiles. Whether this completely makes up for the slower single-file compilation time or not depends on the number of files, size of the files, and so on.
  •  
  • The 2013 linker is faster. This, together with the second bullet, will generally make builds faster in 2013.
  •  
  • The build time of an Edit-Build-Debug cycle is also faster in 2013, but only marginally so, because the first and third bullets are applicable and mutually cancelling. The second bullet is not applicable in most cases.
  •  
  • Compiling a PCH file is much faster in 2013. This only impacts the very first build of a project, the first build following a clean, or a rebuild.
  •  


Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 05/07/2014
424254

Return
Calling the assert macro generates a warning that code will never be executed when the LabWindows/CVI compiler can determine the outcome of the expression.
If the compiler can determine a condition will always have the same outcome, it will return this warning.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 05/07/2014
430785

Return
Compiling causes an error: definition of the macro '_TARGET_FILE_VERSION_' conflicts with the definition used to build the precompiled header message.
This error can occur when using the auto-increment version feature in projects that include precompiled headers. A similar error occurs for _TARGET_PRODUCT_VERSION_.

Workaround: Do a rebuild instead of a build, after modifying a file that does not trigger the compilation of the precompiled header.

Reported Version: 2013  Resolved Version: N/A  Added: 05/07/2014
471567

Return
Generating HTML help from source with array pointer type parameters results in an 'unknown' type generated in the help.
The following function declaration causes this type of error:

static int func(double (*dataArray)[4]);

Workaround:
  •  
  • Define your parameter using exclusively a pointer.
  •  
  • Use a type definition to separate the type declaration of the array from the pointer as follows:

    typedef double tArray[4];

    static int func(tArray* dataArray);
  •  


Reported Version: 2013 SP2  Resolved Version: N/A  Added: 08/22/2014
505265

Return
The FileExists function may fail in projects that use the Vision Builder AI engine.
A File Not Found error may occur when the FindFile function is used in a project that uses functions from the Vision Builder AI engine.

Workaround: Avoid using the FindFile function in a project which uses the Vision Builder AI engine. If it is necessary to use the FindFile function, it will be necessary to separate these two functions into separate projects. For example, the application could be implemented as two separate executables which communicate using shared variables.

Reported Version: 2012  Resolved Version: N/A  Added: 08/03/2015
516928

Return
Including a library (.lib), possibly of an old format, in both the project tree and the LoadExternalModule (LEM) Options dialog causes the following error: error: Input file is not a valid archive.

Workaround: Check a library in the LEM Add Files to Executable dialog only if you intend to use it later with LEM functionality (e.g., using GetExternalModuleAddr).

Reported Version: 2013  Resolved Version: N/A  Added: 08/03/2015
357424

Return
Casting an int to a union does not cause a compile error.
Beginning with LabWindows/CVI 2013, GNU Extensions are enabled by default. Casting to union is a GNU Extension, and a warning is produced instead of an error.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
412828

Return
Building a distribution kit with a long file name can cause LabWindows/CVI to crash on Windows XP.
N/A

Workaround: N/A

Reported Version: 2012  Resolved Version: N/A  Added: 08/22/2016
430409

Return
The compiler may report the build error The compiler has run out of memory if <filename>.obj.cvidefprots exceeds 260 characters.
The compiler cannot create the <filename>.obj.cvidefprots in the config directory if the path exceeds 260 characters.

Workaround: Reduce the total path length of the project file. Reduce or increase the length of the source file name by twelve characters.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
434676

Return
Compiling large source files or functions may cause the compiler to display the following build error: The compiler has run out of memory.
N/A

Workaround: Split up the code from one large function into multiple smaller functions. Split up the source file into multiple smaller files to improve compilation performance.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
438833

Return
Incorrectly configured compiler define causes build error: <command line>:28:9: error: macro names must be identifiers.
N/A

Workaround: In Options»Build Options»Compiler Defines, refer to the Compiler Defines topic in the LabWindows/CVI Help to resolve the incorrect compiler define.

Reported Version: 2012  Resolved Version: N/A  Added: 08/22/2016
447401

Return
Compiler Defines return compile errors when porting code from LabWindows/CVI 2009 to LabWindows/CVI 2010.
In LabWindows/CVI 2009, multiple Compiler Defines are separated by a comma then a space. However, in LabWindows/CVI 2010, multiple Compiler Defines are expected to be separated by only a space. When compiling code in LabWindows/CVI 2010 that complies with the LabWindows/CVI 2009 Compiler Defines format, illegal character build errors are returned.

Workaround: Remove the commas separating the Compiler Defines.

Reported Version: 2010  Resolved Version: N/A  Added: 08/22/2016
475889

Return
GetExternalModuleAddr does not work for stdcall functions in import libraries created with Microsoft Visual Studio.
N/A

Workaround: Rebuild the VC import library with cdecl exports.

Note: This class of functions is obsolete. National Instruments recommends that you instead use the Interface to Win32 API functions LoadLibrary and GetProcAddress to load external modules.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
511542

Return
No access violation is thrown when trying to modify constant strings which are assigned to variables.
For example, the following code executes without an access violation:
<pre>char* text = "__text";
// Here, text will have the value "0_text". The constant string is modified here. An access violation should be thrown.
text[ 0 ] = '0';
// Here, text will still have the value "0_text" since the constant string was modified.
text = "__text";;</pre>

Workaround: Use strcpy.

<pre>char text[ 7 ];
strcpy( text, "__text" );
text[ 0 ] = '0';
strcpy( text, "__text" );</pre>

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
515817

Return
Generating help from source is incorrect on a multibyte OS if the source code tags or file name contains multibyte characters.
N/A

Workaround: N/A

Reported Version: 2012  Resolved Version: N/A  Added: 08/22/2016
543008

Return
The compiler incorrectly issues an uninitialized warning when a locally defined pointer to a structure is followed by a structure definition.
N/A

Workaround: Make sure the pointer to the structure is not followed by a variable definition to the same structure. You can also place the structure definition before the pointer definition, or place a definition of a variable of a different type in between.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
564085

Return
The build for a DLL target does not detect mismatches between header declaration and function definition when exporting symbols from an include file.
This includes mismatches of calling convention and function prototype.

Workaround: If the header used to export symbols is included in the project, the compiler will detect mismatches.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
566083

Return
Old-style function definitions preceded by a prototype are diagnosed with the strict prototypes warning.
Warn if a function is declared or defined without specifying the argument types. An old-style function definition is permitted without a warning if preceded by a declaration that specifies the argument types.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
583937

Return
There are compile errors in the Interactive Window when including windows.h and winnt.h after compiling with only winnt.h included.
N/A

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
586821

Return
Selecting Compile with precompiled include file in Build Options causes Assertion Error in Windows Event Viewer.
N/A

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
588349

Return
A Compile error is thrown in the interactive window when calling the alloca() function.
When making a call to alloca() in Interactive Execution, it fails to build with the message, "error: use of unknown builtin '__builtin_alloca"".

Workaround: Instead of allocation memory on stack using alloca, use malloc to allocate memory on heap.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
591193

Return
When run-time checking is enabled, the first element of a multidimensional array of structures is initialized to NULL.
N/A

Workaround: Initialize array elements using asignment rather than inline initialization.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
555561

Return
The Options»Build Options»Require function prototypes option does not issue compile errors when function declarations are not declared using a full prototype.
N/A

Workaround: Enable -Wstrict-prototypes to benefit from a warning diagnostic when old-style function declarations are used.

Reported Version: 2013  Resolved Version: N/A  Added: 02/22/2017
706577

Return
Casting a double variable to a float produces unexpected results if compiled in 64-bit release mode with no optimizations.
Casting a double to a float in an application compiled in 64-bit release mode with no optimizations can result in unexpected behavior. The value assigned to the float may be completely different from the original double value. It may also result in a stack overflow.

Workaround: N/A

Reported Version: 2013  Resolved Version: 2015 SP1 f2 and 2017 f1 patches  Added: 8/16/2018
Debugging
210086

Return
The LabWindows/CVI environment may hang while debugging with the Variables or Watch windows open.

Workaround: N/A

Reported Version: 2009  Resolved Version: N/A  Added: 05/05/2010
335983

Return
Tooltip for symbol values during debugging may appear on top of the editor's scrollbar.

Workaround: N/A

Reported Version: 8.0  Resolved Version: N/A  Added: 07/24/2012
346034

Return
#define macros cannot be monitored in the Watch window.
If you define a watch expression for a macro, the Watch window will show ERROR: Unknown identifier and type at run time.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 05/07/2014
370682

Return
When the cvidebug.exe process dies or is intentionally stopped, LabWindows/CVI cannot debug again until it has been restarted.
Each time you debug you receive a dialog box stating An unspecified error has occurred, probably due to corrupted data.

Workaround: Restart LabWindows/CVI.

Reported Version: 2013  Resolved Version: N/A  Added: 05/07/2014
423739

Return
The DefineThreadSafeVar macro produces a warning indicating it will never be executed.

Workaround: This is an incorrect warning that can be ignored.

Reported Version: 2013  Resolved Version: N/A  Added: 05/07/2014
438870

Return
Using the debugger to change the value of one variable in an anonymous nested structure changes it for all the variables in the structure with that name.

Workaround: Name the nested structures.

Reported Version: 2013  Resolved Version: N/A  Added: 05/07/2014
438896

Return
LabWindows/CVI does not display a warning message when both a main and a WinMain entry point are defined in a source file.
When main and WinMain are both defined in a source file, only the WinMain entry point will execute at run time. LabWindows/CVI does not warn that main may not execute.

Workaround: N/A

Reported Version: 8.0  Resolved Version: N/A  Added: 05/07/2014
442184

Return
Interface to Win32 API functions cannot be run in the Interactive Execution window.
Linker errors occur when Interface to Win32 API functions are used.

Workaround: Complete the following steps to work around this issue:
  1.  
  2. Create an empty function panel with the same name as the Windows SDK library that you want to use.
  3.  
  4. Save the function panel next to the Windows SDK .lib or copy the Windows SDK .lib next to the function panel.
  5.  
  6. Load the function panel or reattach the program file (Instrument»Edit»Reattach Program).
  7.  
  8. Verify that step 4 succeeded: Instrument»Edit»Show Info.
  9.  
  10. Enable Options»Environment»Include loaded instrument drivers in Interactive window.
  11.  
  12. Run your code snippet.
  13.  


Reported Version: 2013  Resolved Version: N/A  Added: 05/07/2014
456208

Return
The Source Code Browser window displays the same reference to a macro multiple times.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 05/07/2014
460794

Return
The Available Types dialog box in the Watch and Variables and Call Stack windows do not display the full list of types.
The list contains only types that are referenced in the application.

Workaround: If the type you want is not in the list, you can create a Watch Expression that casts the value to the type you want. For example, if you want to interpret variable foo as an unsigned char, and unsigned char is not in the list, you can create a Watch Expression for (unsigned char)foo.

Reported Version: 2013  Resolved Version: N/A  Added: 05/07/2014
460799

Return
The Watch and Variables and Call Stack windows display the type incorrectly after using the Interpret As option multiple times.
If you interpret an int as a char and then interpret it as an unsigned int, the window will show the type as unsigned int (char (int)). The window should show the type as unsigned int (int).

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 05/07/2014
461757

Return
The Break On Change state of a watch expression is lost when stopping and restarting execution or unloading and reloading a workspace.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 05/07/2014
464146

Return
Setting a breakpoint from Breakpoints dialog box on an invalid line while debugging an application causes uncommitted changes in the dialog box to irreversibly take effect.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 05/07/2014
464507

Return
Running the Interactive Execution window a second time after finishing a run of the interactive statements with the Finish Function option causes the Interactive Execution window to crash.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 05/07/2014
464904

Return
The Watch and Variables and Call Stack windows do not mark the item for a pointer to a variable as red if the variable value changes.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 05/07/2014
430376

Return
The Variables and Call Stack, Watch, and Array Display windows do not show the contents of char arrays with more than 252 unprintable characters.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2014
434406

Return
LabWindows/CVI no longer displays a warning while debugging a real-time application if threads are still running on the target when RTmain exits.

Workaround: N/A

Reported Version: 2012  Resolved Version: N/A  Added: 08/22/2014
437356

Return
Stepping over a function call located at the last line in the enclosing lexical scope causes a Step Into instead of a Step Over.

Workaround: Make sure the last statement is not on the same line as the closing curly brace.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2014
438839

Return
LabWindows/CVI displays incorrect or no values for CmtThreadLockHandle and CmtTSQHandle variables when the variables are declared as int.

Workaround: Declare the variables as either CmtThreadLockHandle or CmtTSQHandle instead of int.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2014
443138

Return
The Interactive Execution window does not allow immediate termination when execution is suspended due to a break on change on variable value.

Workaround: Step Over to the next step point or Continue to the next breakpoint.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2014
447051

Return
If the LabWindows/CVI debugger crashes (cvidebug.exe), all of the entries from the Watch window are cleared. Once you begin a new debugging session, the entries are restored to the Watch window.
This scenario may cause LabWindows/CVI to become unstable.

Workaround: Restart LabWindows/CVI.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2014
460394

Return
The Resource Tracking window shows freed resources as allocated if resource tracking is disabled after allocation.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2014
463635

Return
Opening the Graphical Array View for large, dynamically allocated arrays from the Array Display window causes an Index passed is out of range error.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2014
464563

Return
LabWindows/CVI does not allow you to attach to a 64-bit process running on a remote system.
When you attempt to attach to a 64-bit process running remotely, you receive an error stating The current project configuration is not compatible with the debugger.... The Build»Configuration menu selection also becomes out of sync with the configuration displayed in the status bar at the bottom of the editor.

Workaround: You can set the executable and command line correctly for the remote target system using Run»Specify Executable and Command Line and then you can select Run»Debug MyApplication.exe to launch the 64-bit process on the remote machine and debug it.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2014
466209

Return
The DebugPrintf function truncates large strings when printing to the Debug Output window.

Workaround: Split long strings into multiple print statements.

Reported Version: 9.0  Resolved Version: N/A  Added: 08/22/2014
466763

Return
LabWindows/CVI does not show enough digits of precision in tooltips or the Variables and Call Stack window.
The display has a 15-digit limit.

Workaround: N/A

Reported Version: 6.0  Resolved Version: N/A  Added: 08/22/2014
466921

Return
Running a function using its function panel results in an Interactive Execution Unresolved symbol error even if the Include loaded instrument drivers in Interactive window Environment dialog box option is enabled.

Workaround: Save your project after loading the instrument driver.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2014
469910

Return
LabWindows/CVI hangs when stepping through code for a console application and choosing Set Next Statement on the previous line after closing the console window while suspended.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2014
470486

Return
The Interactive Execution window incorrectly excludes the line and offsets the execution highlighting when adding a variable declaration on an instruction line.

Workaround: Do not declare variables on instruction lines in the Interactive Execution window.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2014
470948

Return
The Interactive Execution window does not allow stepping into the main function of a project.

Workaround: The Interactive Execution window allows stepping into the main function when execution is suspended in the project during a debugging session.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2014
472987

Return
The Parameter type incompatible with format specifier non-fatal run-time error does not display source location when 64-bit variables are used in code that causes the run-time error in the Debug64 configuration.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2014
502946

Return
The LabWindows/CVI debugger does not recognize variables that include the $ symbol as part of the variable name.
If you view the value of a variable with a $ in its name in the Variables window while debugging, you will see an Error: Unrecognized Identifier error.

Workaround: The C language specification states that $ is not a valid character to include in a variable name, so it is best to avoid using this character in variable names. This will prevent the error from occurring in the Variables window.

Reported Version: 2013  Resolved Version: N/A  Added: 10/29/2014
465367

Return
If the data slice in an Array Display is changed, the numeric controls, Row and Column, in the Go to Cell dialog correctly change their ranges, but Go to Cell does not go to the correct cell.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/03/2015
470673

Return
Changing the data slice and displaying the format of a 2D char array causes the Array View to become unusable, if the first dimension of the array is bigger than the second.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/03/2015
472358

Return
Terminating execution while the Watch window is closed causes watch expressions to be duplicated.
This can lead to debugging performance decrease as the number of watch expressions increases each time an execution is terminated.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/03/2015
473458

Return
The Variables and Call Stack window occasionally shows ERROR: Unexpected character. when changing the specific type for a variable.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/03/2015
477649

Return
An incorrect uninitalized variable non-fatal run-time error is generated for partially initialized arrays inside of structs.

Workaround: Initialize the array completely or turn off run-time error checking.

Reported Version: 2013 SP1  Resolved Version: N/A  Added: 08/03/2015
478665

Return
A Graph doesn't have that many cursors error appears when debugging an application with multiple arrays shown in the Graphical Array View.

Workaround: Open only one Graphical Array View at a time.

Reported Version: 2013  Resolved Version: N/A  Added: 08/03/2015
479326

Return
The tooltip for an empty field on a function panel displays an = ERROR: Unexpected end of input. error when execution is suspended during debug.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/03/2015
487428

Return
You receive a non-fatal run-time error, Attempt to read beyond end of string, when specifying a string member of a struct returned by a function as the source input for sprintf.

Workaround:
  •  
  • In the struct declaration, specify the string as a char array such of finite size.
  •  
  • Alternatively, you can also use the strcpy function instead of sprintf to perform this action.
  •  


Reported Version: 2013  Resolved Version: N/A  Added: 08/03/2015
503717

Return
Debugging a project while concurrently debugging statements in the Interactive Execution window causes LabWindows/CVI to stop responding to commands.

Workaround: Stop debugging in the Interactive Execution window before debugging a project.

Reported Version: 2013  Resolved Version: N/A  Added: 08/03/2015
504099

Return
A linker error will occur if a global variable is referenced in the Interactive Execution window and if the project which defines the global variable is being debugged.
If a statement such as extern int x; is used in the Interactive Execution window while the project which defines the variable x is being debugged, attempting to run statements in the Interactive Execution window will result in a linking error.

Workaround: Declare the global variable in a second source file. Alternately, run the Interactive Execution window statements while not debugging the project which defines the global variable.

Reported Version: 2013  Resolved Version: N/A  Added: 08/03/2015
515028

Return
When trying to browse for the members of a structure () inside the Watch window, no browse info is found.

Workaround: Call browse info from the source rather than from the Watch window.

Reported Version: 2013  Resolved Version: N/A  Added: 08/03/2015
515433

Return
When a compilation error occurs while running a function panel interactively, information about which function panel field caused the compilation error is not shown.

Workaround: Double-click the error in the Build Output window to see where the failure occurs in the Interactive Execution window.

Reported Version: 2013  Resolved Version: N/A  Added: 08/03/2015
515436

Return
When using a user-interactive function (e.g., printf) in the Interactive Execution window, the console is not closed when execution finishes.

Workaround: Select Build»Clear Interactive Declarations to close the console.

Reported Version: 2012  Resolved Version: N/A  Added: 08/03/2015
515499

Return
Active breakpoints in the Interactive Execution window are hit when running function panels interactively.

Workaround: Toggle breakpoints in the Interactive Execution window before running a function panel.

Reported Version: 2012  Resolved Version: N/A  Added: 08/03/2015
515639

Return
An uninitialized pointer in a structure cannot be modified in the Variables and Call Stack and Watch windows. In the Watch window the pointer has the value Uninitialized.

Workaround: N/A

Reported Version: 2015  Resolved Version: N/A  Added: 08/03/2015
519172

Return
If you try to stop a program running in the Interactive Execution window after the cvidebug.exe process has been terminated, the editor crashes.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/03/2015
533817

Return
The editable data tooltip does not display characters after a newline character.

Workaround: Use the Watch window or the Variables and Call Stack window to correctly view the variable's value.

Reported Version: 8.0  Resolved Version: N/A  Added: 08/03/2015
438921

Return
The Variables, Call Stack, and Watch windows display incorrect indices for multidimensional arrays with one dimension of size one.
If a multi-dimensional array has one dimension of size one, expanding an element corresponding to this dimension is displayed with elements from indices zero to the end of the array in the Variables and Call Stack and Watch windows.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
439442

Return
Compilation errors in the Interactive Execution window do not correctly specify the error location.
N/A

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
439443

Return
The Interactive Execution window displays error dialogs when run with empty contents after pressing Edit»Clear Window.
The following error dialogs are displayed: The interactive window was terminated unexpectedly and You are not debugging a process.

Workaround: Manually delete the contents of the Interactive Execution window.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
439990

Return
The Interactive Execution window does not honor disabling Break on»First Chance Exceptions or executing SetBreakOnFirstChanceExceptions (0);.
N/A

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
442198

Return
64-bit addresses are truncated in the GetExternalModuleAddrEx and GetExternalModuleAddr Function Panels.
N/A

Workaround: Open the Interactive window and hover over the result of GetExternalModuleAddrEx or GetExternalModuleAddr to see the full address.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
449641

Return
Details are not displayed when loading an invalid file in the Resource Tracking window.
When trying to load an invalid file in the Resource Tracking window, a dialog appears that states: "Error in file '' on line".

Workaround: N/A

Reported Version: 2009  Resolved Version: N/A  Added: 08/22/2016
449642

Return
Loading a corrupted file into the Resource Tracking window can crash LabWindows/CVI.
N/A

Workaround: N/A

Reported Version: 9.0  Resolved Version: N/A  Added: 08/22/2016
450318

Return
When an Interactive Execution contains an unclosed brace the code does not execute and an error is not generated.
N/A

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
453270

Return
Graphical Array View does not work for 2D arrays with a dimension of size one.
N/A

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
456818

Return
If a function contains a function declaration, the Source Code Browser incorrectly lists the declared function in the Called from view pane of a function called after the declaration.
For example, the following code calls foo2 from main, but the Source Code Browser incorrectly lists foo2 as being called from foo instead of main:

void foo2(void);

int main (int argc, char *argv[])
{
int foo(void);
foo2();
return 0;
}

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
463300

Return
Interactive Executions only display errors from included header files the first time they are built.
N/A

Workaround: Select Build»Clear Interactive Declarations or resolve the build error before building a second time.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
463922

Return
If there are expanded items in a Watch window after running an Interactive Execution, opening a different project displays the dialog There are no items in the list control.
N/A

Workaround: Clear the interactive execution before opening a different project.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
464227

Return
Editing the value of a variable in a Watch window displays Value illegal or out of range after running an Interactive Execution.
N/A

Workaround: Edit the value in the Variables or Memory window.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
473970

Return
Object files that use CVI library functions do not produce user protection errors when called from LoadExternalModule.
N/A

Workaround: Produce a .lib file instead to call from LoadExternalModule. Alternatively, move the code from the object file into your main program.

Note: This class of functions is obsolete. National Instruments recommends that you instead use the Interface to Win32 API functions LoadLibrary and GetProcAddress to load external modules.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
478903

Return
In the Variables and Call Stack window, the "[Frames below may be incorrect or incomplete.] entry disrupts navigation with the Up Call Stack and Down Call Stack buttons on the toolbar.
N/A

Workaround: Double click an item on the stack to navigate to that item.

Reported Version: 2013 SP2  Resolved Version: N/A  Added: 08/22/2016
482391

Return
When running an Interactive Execution while not suspended on a valid steppoint, CVI incorrectly reports "LabWindows/CVI could not launch the interactive window. Please repair your installation of LabWindows/CVI".
The correct message is "The operation is available only when you are suspended on a valid steppoint. Step Over to the next steppoint or Continue to the next breakpoint".

Workaround: N/A

Reported Version: 2013 SP2  Resolved Version: N/A  Added: 08/22/2016
510665

Return
View Variable Value only shows the first element of char* variables in the Array Display when the char* variable value is set using CA_BSTRGetCString.
N/A

Workaround: Open the variable from the Variables and Call Stack window.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
515795

Return
Red highlighted text in the Memory window is not always reset after every execution.
N/A

Workaround: The Watch window correctly highlights a variable value in red if it has changed since the last time a program was suspended.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
IDKnown Issue
515797

Return
Editing a value in the Memory window does not highlight that value in red when using the Memory window for the first time after opening a project.
N/A

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
541876

Return
Watch expressions that are offset from a declared symbol's address are not editable.
N/A

Workaround: N/A

Reported Version: 2012  Resolved Version: N/A  Added: 08/22/2016
553889

Return
The Watch window shows the global variable address rather than the thread-local address for variables that use the __thread storage class.
N/A

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
568788

Return
The Type of character arrays does not update in watch expressions when you perform pointer arithmetic on them.
N/A

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
570889

Return
Accessing an array element of a pointer to an incomplete structure that is dynamically allocated as an array of fixed structures causes a Dereference of out-of-bounds pointer user protection debugging error.
The following code can reproduce this error:


<pre>
#include <ansi_c.h>

typedef struct THING {
unsigned int t_id[ 1 ];
} Thing;

#define THING_COUNT 2

int main( void )
{
Thing* things;
things = ( Thing* )calloc( THING_COUNT, sizeof( Thing ));
( things + THING_COUNT -1 )->t_id[ 0 ];
}
</pre>


Workaround: Turn off run time checking or avoid using incomplete structures.

Reported Version: 2012  Resolved Version: N/A  Added: 08/22/2016
580336

Return
LabWindows/CVI displays an error that reads Another debugging process is already in progress when the Attach to Process dialog is opened after running statements in the Interactive Execution window.
N/A

Workaround: Clear the Interactive Execution window.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
591529

Return
After changing the type of a local variable using the Interpret As option from the Variables and Call Stack window, the displayed type is incorrect.
Use: <new type>(<declared type>), instead of: <new type>(<old type displayed>).

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
591577

Return
The debugger highlights all expressions in a multi-variable declaration block broken over multiple lines rather than highlighting individual declarations.
<pre>// Setting a breakpoint on the line with y = 2; causes the debugger to highlight starting at int x...
void example( void )
{
int x = 1,
y = 2;
}</pre>

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
396028

Return
The LabWindows/CVI 2013 and newer debugger is slower than LabWindows/CVI 2012.
LabWindows/CVI 2013 and newer debugger is slower than LabWindows/CVI 2012 in these known cases:

  •  
  • Viewing a large number of variables in the Variables Window
  •  
  • Viewing a large array in the Array Display Window
  •  
  • Viewing a large array in the Graphical Array View
  •  


Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 05/22/2017
525073

Return
LabWindows/CVI may slow down or hang when performing extended debugging with the Resource Tracking window.
In some cases, the LabWindows/CVI 2013 debugger may slow down or hang when a project is compiled with extended debugging and you are using the Resource Tracking window.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 05/22/2017
Development Environment
189843

Return
The Perforce 2009.1 client may cause LabWindows/CVI 2009 to crash.
LabWindows/CVI may crash when the Perforce SCC DLL is unloaded.

Workaround: Upgrade to the Perforce 2009.2 client.

Reported Version: 8.1  Resolved Version: N/A  Added: 05/05/2010
193733

Return
Launching the DataSocket Binding dialog box may cause LabWindows/CVI to hang on Windows 7.

Workaround: Switch away from LabWindows/CVI to another application, and then switch back to LabWindows/CVI.

Reported Version: 2009  Resolved Version: N/A  Added: 05/05/2010
216549

Return
LabWindows/CVI installs KeyHelp.ocx, which contains a security vulnerability.
For more information, refer to this link.

Workaround: This component is used for help tooltips in the LabWindows/CVI User Interface Editor. It can be safely prevented from being used in IE by using the Microsoft kill bit mechanism. The CLSIDs for this control are: {16DDBCA2-9F0B-4927-9315-62D8893FC7E8}, {B7ECFD41-BE62-11D2-B9A8-00104B138C8C}, {2603E4AA-D6F2-447E-8B9B-BE8F4CFCD79B}, {D03D48E0-D399-11D2-B9A8-00104B138C8C}, {7773D66A-023C-4791-98BE-0AEBEFEF16B2}, {EAEED2BE-6AEB-4C48-B18C-F03EEDF9EED8}, {338E6F5B-0988-4EC5-9805-82224A9AC4FF}, {45E66957-2932-432A-A156-31503DF0A681}, {1E57C6C4-B069-11D3-8D43-00104B138C8C}, {85BD2BC1-D3CD-11D3-8BF4-00104B138C8C}.

Reported Version: 2009 SP1  Resolved Version: N/A  Added: 09/17/2010
227324

Return
LabWindows/CVI cannot copy files to the VXIPnP directories on Windows Vista and later.
These directories are locked by default, which is not the correct behavior.

Workaround: Install VISA, which will unlock these directories.

Reported Version: 2009  Resolved Version: N/A  Added: 03/10/2011
289314

Return
User-defined types always receive an asterisk when used as output types in function panels.
For instance, if you define a custom type as

typedef char[256] String255;

you would not want it to have an asterisk appended to it when used as an output type.

Workaround: N/A

Reported Version: 6.0  Resolved Version: N/A  Added: 03/24/2011
308191

Return
A multi-project workspace with projects targeting both 32-bit and 64-bit can incorrectly display import libraries.
For example, consider the case where you have a workspace with two projects. If both projects have import libraries associated with them, and one project is 32-bit and one project is 64-bit, the bitness marking of the import libraries may be confusing. If the 64-bit project is the active project, the import libraries of the 32-bit project will show as dimmed and 64-bit. Then, if you make the 32-bit project the active project, the bitness of its import libraries will show correctly, but the import libraries of the 64-bit project will now display as 32-bit and dimmed.

Workaround: N/A

Reported Version: 2009  Resolved Version: N/A  Added: 07/27/2011
329035

Return
LabWindows/CVI Conversion Wizard does not transfer 'Compile with precompiled include file' setting to 'Precompiled Headers' setting in Microsoft Visual Studio.

Workaround: N/A

Reported Version: 9.0  Resolved Version: N/A  Added: 01/09/2012
332047

Return
LabWindows/CVI stops responding while searching for an inaccessible network location.
When LabWindows/CVI is searching for a file at a network location that is not available, the environment stops responding.

Workaround: The search times out after about 2 minutes and the environment will resume. Avoid attempts to access network locations that may not be available.

Reported Version: 8.5.1  Resolved Version: N/A  Added: 01/10/2012
322905

Return
Files in a project may not display source control icons when a LabWindows/CVI project is associated with the Perforce client.
If the Perforce Workspace root path has different casing than the actual path, then the icons do not display.

Workaround: N/A

Reported Version: 2010  Resolved Version: N/A  Added: 02/15/2012
333837

Return
LabWindows/CVI projects are not handled properly when adding them from new workspaces in instances of LabWindows/CVI created from just-in-time debugging.
Adding or removing a project from the Project Tree in an instance of LabWindows/CVI created by the just-in-time debugger can cause unexpected behavior.

Workaround: Do not add projects to the Project from instances of LabWindows/CVI created by the just-in-time debugger.

Reported Version: 2010  Resolved Version: N/A  Added: 02/15/2012
334920

Return
Corners of Source Editor windows are painted black in non-tabbed Workspace when opened.
When opening a workspace that has the Show Tabbed Workspace option disabled and at least one source code window open, the top corners of the Source Editor windows are painted black.

Workaround: N/A

Reported Version: 9.0  Resolved Version: N/A  Added: 02/15/2012
357212

Return
The save icon does not dim after saving a file.
After a file is saved, the save icon is not dimmed. Once you click anywhere in the LabWindows/CVI editor after saving, the icon will then dim.

Workaround: N/A

Reported Version: 2012  Resolved Version: N/A  Added: 07/17/2012
361958

Return
The Project Tree does not auto-hide when a UIR file is opened.
Other file types do auto-hide the Project Tree. This behavior occurs only if you enable the Auto hide Project Tree and Library Tree option in the Environment dialog box.

Workaround: N/A

Reported Version: 9.0  Resolved Version: N/A  Added: 07/18/2012
363196

Return
Attribute passed is not valid error when declaring a variable in a function panel.
The error is incorrectly displayed and can be ignored.

Workaround: N/A

Reported Version: 2012  Resolved Version: N/A  Added: 07/18/2012
347511

Return
Microsoft Visual Studio does not rebuild a LabWindows/CVI project if a UIR file changes but its header file does not.

Workaround: N/A

Reported Version: 8.0  Resolved Version: N/A  Added: 07/22/2012
347986

Return
The Load UI resource file dialog box in the User Interface Localizer utility unloads the currently loaded localization.
If changes have been made in the loaded file, a dialog box prompts you to save.

Workaround: N/A

Reported Version: 8.0  Resolved Version: N/A  Added: 07/22/2012
356708

Return
The Source window cursor can persist after selecting text and editing a variable tooltip.
This behavior can cause two cursors to exist at the same time.

Workaround: Scroll the Source Editor window up/down to make the old cursor go away.N/A

Reported Version: 2009  Resolved Version: N/A  Added: 07/22/2012
337770

Return
Setting LabWindows/CVI to "Run as administrator" will open a new instance of LabWindows/CVI each time you open a file associated with LabWindows/CVI.

Workaround: If you want to use LabWindows/CVI as administrator you can check the "Run as administrator" option from the Advanced button of the Shortcut tab instead of the Compatibility tab. You can access these options by right-clicking the LabWindows/CVI icon on your desktop and selecting Properties.

Reported Version: 8.5  Resolved Version: N/A  Added: 07/24/2012
333302

Return
Auto Backup will provide an error if the file is marked as read-only.
This behavior is common if the file is stored in source control. Auto Backup may also take effect even if the file was not modified.

Workaround: Disable Auto Backup in Environment Options.

Reported Version: 8.0  Resolved Version: N/A  Added: 07/25/2012
335488

Return
Excluded import libraries that represent both 32-bit and 64-bit .lib files are no longer dimmed after switching configurations.
The .lib file is excluded but is not dimmed.

Workaround: N/A

Reported Version: 2009  Resolved Version: N/A  Added: 07/25/2012
366229

Return
The CVIXMLGetNumChildElements function does not count child elements included in an XML entity.

Workaround: N/A

Reported Version: 7.0  Resolved Version: N/A  Added: 08/13/2012
440070

Return
The Find Next feature of the Find dialog box does not move to new results on subsequent uses.
If you do not move the text caret from the first result you find and subsequently click Find Next from the Find dialog, you stay at the same result.

Workaround:
  •  
  • Navigate search results using the Find Results pane.
  •  
  • Press <F3> to navigate the results.
  •  


Reported Version: 6.0  Resolved Version: N/A  Added: 12/06/2013
390670

Return
When you add a line continuation character \ to the end of a comment line initiated by the \\ symbol, the syntax highlighting feature does not continue to the next line, indicating the next line continues the comment.
This behavior can be demonstrated with the following code snippet:


\\This is a comment. \

This is also a comment.

Workaround: Do not use a line continuation \ to break a comment between lines.

Reported Version: 6.0  Resolved Version: N/A  Added: 03/28/2014
451665

Return
The UI to Code Converter generates code containing an undefined function, InsertCtrlInCtrlArray.
InsertCtrlInCtrlArray was renamed to InsertCtrlArrayItem in LabWindows/CVI 2010.

Workaround: Replace all occurrences of InsertCtrlInCtrlArray with InsertCtrlArrayItem.

Reported Version: 2010  Resolved Version: N/A  Added: 03/28/2014
369029

Return
The compile process does not wait for user response about missing include statements for header files.
In versions of LabWindows/CVI previous to 2013, compiling a project with missing header files caused a dialog box to appear, prompting you to include the missing headers. The compile process did not continue until the dialog box was dismissed. Now, the compile continues despite the dialog box, and the project has to be rebuilt after adding the missing headers.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 05/07/2014
375449

Return
Upgrading LabWindows/CVI breaks paths to Clang in .ecc configuration files.

Workaround: Edit the .ecc file to point to the version of LabWindows/CVI you are trying to use.

Reported Version: 2012  Resolved Version: N/A  Added: 05/07/2014
375463

Return
File icons may obscure full pathnames in the Project Tree.

Workaround: N/A

Reported Version: 8.5  Resolved Version: N/A  Added: 05/07/2014
383011

Return
Unable to close the Open GL plot Properties dialog box after right-clicking the Open GL plot twice while the dialog box is open.

Workaround: N/A

Reported Version: 8.0  Resolved Version: N/A  Added: 05/07/2014
391648

Return
Show Completions (<Ctrl-Space>) does not list members in anonymous structures or unions.

Workaround: Do not use anonymous, nested structs. Declare nested components using named fields.

Reported Version: 2013  Resolved Version: N/A  Added: 05/07/2014
403299

Return
The Functions in File ring is not wide enough to display some function names.

Workaround: Open the drop-down view to see the function names in full length.

Reported Version: 2013  Resolved Version: N/A  Added: 05/07/2014
411386

Return
The function panel size changes how function calls are inserted into code.
For example, if the function panel is not maximized, the function call is added over multiple lines. However, if you maximize the function panel, the function call is inserted on one line.

Workaround: N/A

Reported Version: 2009  Resolved Version: N/A  Added: 05/07/2014
412464

Return
Opening, editing, and saving a source file with a very long file path causes LabWindows/CVI to crash.
Previous versions of LabWindows/CVI display a Badly formed pathname message instead of crashing.

Workaround: N/A

Reported Version: 9.0  Resolved Version: N/A  Added: 05/07/2014
429854

Return
The Find in Files feature fails when searching all files (*.*) in a directory containing .svn-base files.

Workaround: Explicitly choose file types to search rather than using *.* in the File types field.

Reported Version: 2009  Resolved Version: N/A  Added: 05/07/2014
437791

Return
LabWindows/CVI does not handle edge-specific maximization when restoring from a minimized state.
Windows 7 introduced the ability to maximize only in one direction—only vertically or only horizontally. When you close the development environment with the Workspace window in an edge-specific, maximized state, it loses the original size of the window.

Workaround: N/A

Reported Version: 2010  Resolved Version: N/A  Added: 05/07/2014
438547

Return
The Functions in File dialog box immediately starts scrolling up when opened.
When a ring control contains items that can no longer be displayed on the screen, LabWindows/CVI opens a modal dialog box containing a list box with all the items in the ring.

Workaround: N/A

Reported Version: 2012  Resolved Version: N/A  Added: 05/07/2014
438733

Return
If Hide windows when application is running is enabled, and a run-time crash occurs in the Interactive Execution window, the development environment becomes hidden and cannot be restored.

Workaround: Select Show windows from the context menu of the task bar.

Reported Version: 8.0  Resolved Version: N/A  Added: 05/07/2014
384832

Return
Adding a file that is under source code control (SCC) using the Edit Project dialog box does not mark the file as being under SCC in the Project Tree.

Workaround: Add files using Edit»Add Files to Project.

Reported Version: 8.0  Resolved Version: N/A  Added: 08/22/2014
391403

Return
Autoscale is a valid option for the y-axis of a strip chart, but the option is missing from the Attribute Browser.

Workaround: Edit the option in the Edit Strip Chart dialog box.

Reported Version: 2009  Resolved Version: N/A  Added: 08/22/2014
402786

Return
Show Completions <Ctrl-Space> does not work if a multi-line string starts with special char like {, }, ;, or #.
You cannot perform Show Completions on foob in the following snippet, unless the { is removed from the beginning of the string.

int foobar;

printf("\

{sdf = %d", foob

Workaround: N/A

Reported Version: 8.0  Resolved Version: N/A  Added: 08/22/2014
408099

Return
Pressing <Ctrl-Tab> to switch between tabs causes a Panel, menu bar, or control array handle is invalid message to display if confined function panel windows are open.

Workaround: N/A

Reported Version: 7.1  Resolved Version: N/A  Added: 08/22/2014
409526

Return
Macros defined in precompiled headers are not included in browse information.

Workaround: Use the Find in Files feature (<Ctrl-Shift-F>) to find the macro.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2014
423818

Return
The Show Completions feature fails to display context help for function parameters once the second parameter is highlighted if the function call immediately follows a curly brace.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2014
431732

Return
The LabWindows/CVI debugger starts applications outside of the window space in Windows 8.1 if you enable Variable, Continuous Size of Snap Views in Windows and LabWindows/CVI is used in the right-half of the screen.

Workaround: Use LabWindows/CVI in the left half of the screen.

Reported Version: 8.0  Resolved Version: N/A  Added: 08/22/2014
435479

Return
Creating a file with the New»File from Template option that has the same path and name as an existing file results in an out of memory error.

Workaround: Create a file with a different name or delete the existing file from disk before creating a file with the same path and name.

Reported Version: 2010  Resolved Version: N/A  Added: 08/22/2014
436648

Return
Enabling the Compile with precompiled include file option in the Build Options dialog box causes a The User Interface Manager could not be opened to be displayed.

Workaround: Save the project on disk.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2014
446313

Return
A dialog box explaining that saving UIR files will generate new versions of their include files is incorrectly displayed multiple times if there are multiple unsaved UIR files containing custom controls.

Workaround: N/A

Reported Version: 2010  Resolved Version: N/A  Added: 08/22/2014
463642

Return
Watch expressions cannot be deleted by pressing <Delete>, if the Break On Change checkbox has focus.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2014
463873

Return
Although Insert Mode is shown as active in the Array Display window when the window displays a data slice, the Insert Mode no longer has any effect.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2014
463921

Return
A tooltip containing Invisible is incorrectly displayed in the Memory Display window after maximizing and restoring the window.

Workaround: The tooltip disappears after you confine the Memory Display window.

Reported Version: 8.0  Resolved Version: N/A  Added: 08/22/2014
467070

Return
The Maximum and Minimum fields in the Edit Table Cell dialog box are not wide enough to show int64 values.

Workaround: N/A

Reported Version: 8.5  Resolved Version: N/A  Added: 08/22/2014
467775

Return
Enabling LoadExternalModule on one of the default Interface to Win32 API libraries and subsequently removing the library from the project tree causes the Interface to Win32 API library to remain forcibly included.
The .prj file still contains an entry for the library under the [Modules Forced Into Executable] tag.

Workaround: Add the Interface to Win32 API library file back to the project tree, uncheck the Interface to Win32 API library in the Add Files to Executable dialog box, and then remove the library from the project.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2014
470691

Return
The Build Output window highlights only error rows after double-clicking an error when building with an external compiler for release configuration.
Normally the correct column is highlighted upon double-clicking the error message.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2014
473109

Return
Some data types such as _Bool and _Complex are not displayed correctly in function prototype tooltips.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2014
473496

Return
Data tooltips have a character entry limit that is about 24 characters at a time.

Workaround: Close and re-open the data tooltip to enter more characters than the limit.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2014
475321

Return
Variables and Call Stack window columns incorrectly display extra columns, and columns are displaced after resizing columns while scrolling.

Workaround:
  •  
  • Do not scroll the mouse wheel while resizing the column divider of the tree control in the Variables and Call Stack window.
  •  
  • To repair the Variables and Call Stack window after the bug occurs, restart LabWindows/CVI.
  •  


Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2014
477231

Return
Incorrect confirmation prompts appear when exiting graph or chart dialog boxes.
These prompts can occur with the following scenarios:

  •  
  • When you edit the graph cursors, graph annotations, or strip chart traces dialog boxes, and you modify only the active item control (Number of Cursors, Current Annotation, or Number of Traces), you have not modified the state of the control. Therefore, you should not be prompted with a confirmation of changes message if you try to exit the dialog box without saving (by clicking the panel's close button). However, the prompt appears.
  •  
  • If you modify only the axis name option in the Edit Axis Settings dialog box and try to exit without saving (by clicking the panel's close button), you should be prompted to save your changes. Yet, the prompt does not appear.
  •  
  • When you edit most sub-dialog boxes of the main Edit Graph or Edit Strip Chart dialog boxes, and you make some changes in those sub-dialog boxes but then exit without saving changes (by selecting Yes in the "Are you sure you want to discard the changes" prompt), when you then exit the main dialog box without making any further changes (by clicking the main dialog's close button), you should not be prompted to save changes. However, the prompt appears.
  •  


Workaround: N/A

Reported Version: 6.0  Resolved Version: N/A  Added: 08/22/2014
477287

Return
The Options»Preprocess Source File feature truncates output after 1024 characters on a line.

Workaround: N/A

Reported Version: 2012  Resolved Version: N/A  Added: 08/22/2014
499830

Return
Text for Custom Build Actions in the Build Steps dialog box may become corrupted when dialog box is closed.
When the Custom Build Actions text is edited on the Build»Build Steps dialog box, the text may become corrupted when the dialog box is closed. If corruption has occurred, re-opening the dialog will show unexpected characters at the end of one or more of the lines in the Custom Build Actions dialog box. This could cause errors to occur when the custom build actions are executed during the build process.

Workaround: If build errors occur due to corruption in the Custom Build Actions text, re-open the Build Steps dialog box and remove the corrupt characters from the Custom Build Actions field.

Reported Version: 2013 SP2  Resolved Version: N/A  Added: 10/29/2014
470220

Return
Enabling both the Expand tabs to spaces when saving files and Convert leading spaces to tabs when loading files Editor Preferences options causes the current line statement to be highlighted incorrectly when debugging.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/03/2015
471435

Return
Source code completion does not work properly following a / operator.

Workaround: N/A

Reported Version: 8.1  Resolved Version: N/A  Added: 08/03/2015
479810

Return
Options»Create Object File does not throw errors if the output object file is read-only.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/03/2015
489731

Return
The Variables and Call Stack window will not retain its position when LabWindows/CVI is restarted.
If you right-click the Variables and Call Stack window, choose Release Window, and re-position the window, its position will not be saved when LabWindows/CVI is closed.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/03/2015
492787

Return
"The buffer passed was too small for this operation" error will occur when entering text for a multiline tooltip in the User Interface Editor.
This issue will occur for all controls and is not dependent on the length of the text entered for the multiline tooltip.

Workaround: There are two possible workarounds to this issue:
  •  
  • Use \n characters to create line breaks in the Tooltip Text field of the Attribute Browser instead of using the Edit multiline tooltip text... option in the Tooltip Text drop-down.
  •  
  • Programmatically set the tooltip attribute rather than using the dialog.
  •  


Reported Version: 2013 SP2  Resolved Version: N/A  Added: 08/03/2015
493985

Return
Closing the Format and Precision dialog while editing default cell values will cause the Edit Default Cell Values dialog to close.
N/A

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/03/2015
504102

Return
Interactive Execution will create a local copy of global variables instead of using the global variable reference.
When the Interactive Execution window is used to execute a statement such as extern int x;, a separate copy of the x variable will be created rather than referencing the existing global variable x.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/03/2015
509337

Return
Distribution Builder may not work properly if the distribution is stored at a network location requiring authentication.
If the distribution is stored at a network location and that network location requires authentication, the Distribution Builder may not work properly unless you have previously provided login credentials for the network location in Windows Explorer. Behavior may include seeing the Select Source dialog reappear continually throughout the build process.

Workaround: Before building the distribution, manually navigate to the network location in Windows Explorer and provide login information when prompted.

Reported Version: 8.0  Resolved Version: N/A  Added: 08/03/2015
512779

Return
The function prototype tooltip will not appear if a struct containing a member with the same name as the function is declared between the function declaration and function definition.
The function prototype tooltip will not be displayed if a struct is defined between the function declaration and function definition if the struct contains a member with the same name as the function. For example, in the following code, a function prototype tooltip will not be displayed when the foo function is used:

int foo(int param);

struct myStruct {
int foo;
};

void main() {
foo( // Function prototype tooltip will not be displayed when this line is typed
}


Workaround: Avoid defining structures between function declarations and definitions when the structure contains a member with a name shared by the function. For example, the code could be written in this way:


struct myStruct {
int foo;
};

int foo;

void main() {
foo( // Function prototype tooltip will not be displayed when this line is typed
}


Reported Version: 2013  Resolved Version: N/A  Added: 08/03/2015
515994

Return
When the Control Data Type of a Function Panel is a multi-dimensional array, the Select Variable result list is empty.

Workaround: Use pointers to add dimensions when necessary.

Reported Version: 2013  Resolved Version: N/A  Added: 08/03/2015
519487

Return
The source editor tabs are not updated when cycling through files during a Resolve All Excluded Lines operation.

Workaround: N/A

Reported Version: 8.5  Resolved Version: N/A  Added: 08/03/2015
412413

Return
LabWindows/CVI crashes when creating new files in path lengths that exceed 260 characters.
N/A

Workaround: Reduce the total path length of the new file.

Reported Version: 2012  Resolved Version: N/A  Added: 08/22/2016
412461

Return
Browse information is not found after renaming a project using the File»Save <projectname,prj> As command.
N/A

Workaround: Type the old project name into the Identifier/Filename control of the Source Code Browser.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
412976

Return
An output directory at a long path specified in the IVI Instrument Driver Wizard (Tools»IVI Development»Create IVI Specific Driver) can cause LabWindows/CVI to crash.
N/A

Workaround: N/A

Reported Version: 2012  Resolved Version: N/A  Added: 08/22/2016
414649

Return
The Scopedem example might return the non-fatal run-time error Attempt to write beyond end of string.
This occurs due to long file paths selected to store data.

Workaround: Increase the size of the filestring array in the ViewDataPoints function.

Reported Version: 2012  Resolved Version: N/A  Added: 08/22/2016
429608

Return
A Confirm File Copy dialog box appears when creating a project from template with a long path.
N/A

Workaround: N/A

Reported Version: 8.5  Resolved Version: N/A  Added: 08/22/2016
430183

Return
LabWindows/CVI cannot open files from paths that contain composed Unicode characters.
N/A

Workaround: Rename or move the file to a path name that does contain composed Unicode characters.

Reported Version: 3.0  Resolved Version: N/A  Added: 08/22/2016
430728

Return
A Badly formed pathname error may appear when creating a Project from Template (File»New»Project from Template).
This error occurs if the project template contains a Workspace and the Add this project to the current workspace is checked in the New Project from Template dialog box.

Workaround: Uncheck the Add this project to the current workspace option.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
430735

Return
LabWindows/CVI enters a bad state if you create a new folder in a file dialog launched from LabWindows/CVI but do not commit the new folder name by pressing the <Enter> key.
After closing the file dialog, menus and menu bar buttons no longer respond to user input.

Workaround: Minimize and restore the LabWindows/CVI window.

Reported Version: 8.0  Resolved Version: N/A  Added: 08/22/2016
432769

Return
The Debugging Level Build Option is reset to Standard after the Run-time Support Target Setting is changed.
N/A

Workaround: N/A

Reported Version: 8.5  Resolved Version: N/A  Added: 08/22/2016
433855

Return
Variables declared in macro code blocks are not shown in the Variables tab when browsing a source file using Window»Source Code Browser.
N/A

Workaround: Select Browse Identifier from the context menu of the selected variable.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
437898

Return
Double-clicking an NI DataStore Results Display ActiveX control in the User Interface Editor can cause LabWindows/CVI to crash.
N/A

Workaround: N/A

Reported Version: 7.1  Resolved Version: N/A  Added: 08/22/2016
438144

Return
UI to Code Converter may generate code that yields a non-fatal run-time error.
When using the UI to Code Converter (Tools»UI to Code Converter) to generate code from a UIR file that contains a tree control, deselecting the Skip default attributes option will generate code that yields the non-fatal runtime error The index passed is out of range.

Workaround: Manually edit the generated code which contains the following line of code errChk(SetTreeColumnAttribute (hPanel, PANEL_TREE, 0, ATTR_COLUMN_VISIBLE, 1)); by passing a non-zero value for the Column_Index parameter.

Reported Version: 2012  Resolved Version: N/A  Added: 08/22/2016
438730

Return
The Key in the Edit Cell dialog box of a Table control displays the incorrect value after configuring subsequent cell Key values.
This behavior occurs when setting the Modifier Key value to either MenuKey (Ctrl) or Shift+MenuKey (Ctrl) and the Key value to a letter (A-Z), subsequently setting a different cell's Key value to something different than the previous cell's Key value, and finally switching back to the previous cell's Edit Cell dialog box.

Workaround: N/A

Reported Version: 8.0  Resolved Version: N/A  Added: 08/22/2016
438842

Return
ATTR_TOOLTIP_HIDE_DELAY is not removed when saving a UIR file for previous versions of LabWindows/CVI.
N/A

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
441568

Return
Incorrect East European characters shown after loading a localization file in the Localization tool on a multibyte OS localized in an Eastern European language.
N/A

Workaround: Choose Eastern European again as the Local Language in the Localization tool.

Reported Version: 2009  Resolved Version: N/A  Added: 08/22/2016
IDKnown Issue
441569

Return
The panel title and any tooltips are not displayed with East European characters on a multibyte OS localized in an Eastern European language.
N/A

Workaround: N/A

Reported Version: 2009  Resolved Version: N/A  Added: 08/22/2016
454409

Return
Unexcluding a source line is not reflected in the next build unless the change is saved before compiling.
LabWindows/CVI saves changes before compiling by default, but this can be changed at Options»Environment»Save changes before compiling.

Workaround: Rebuild the project.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
463586

Return
Clicking on the ... button to the right of the Network Variable Pathname parameter in the function panel for CNVCreateSubscriber causes a 'The attribute value passed is not valid' error.
N/A

Workaround: N/A

Reported Version: 8.1  Resolved Version: N/A  Added: 08/22/2016
464163

Return
If a User Interface Resource (.uir) file has been changed, the associated header file will be regenerated when building the project, even if there are no changes required to the header.
N/A

Workaround: Save the .uir file before building the project.

Reported Version: 8.0  Resolved Version: N/A  Added: 08/22/2016
488375

Return
The Find UI Object (<Ctrl-Shift-U>) feature does not work for controls on tabs which are not being shown.
N/A

Workaround: N/A

Reported Version: 8.0  Resolved Version: N/A  Added: 08/22/2016
501555

Return
The View » Include File menu item opens ansi_c.h instead of lowlvlio.h for all Low-Level IO function panels.
N/A

Workaround: N/A

Reported Version: 6.0  Resolved Version: N/A  Added: 08/22/2016
504121

Return
No prototype is displayed while cursor is on a function pointer parameter.
Edit » Show Prototype or Ctrl+Shift+Space fails to show the prototype of a function if the cursor is located inside parentheses that surround the name of a function pointer parameter.

Workaround: Place the cursor on the function name

Reported Version: 8.0  Resolved Version: N/A  Added: 08/22/2016
533828

Return
Variables Window shows two entries for a redefined variable.
N/A

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
543053

Return
Some macros are listed twice in Predefined Macros dialog.
N/A

Workaround: N/A

Reported Version: 2015  Resolved Version: N/A  Added: 08/22/2016
543055

Return
The predefined macros in the Build Options dialog lists macros for previously selected configuration when All Configurations is selected in Configuration ring.
N/A

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
555915

Return
The Information Status of the UI editor does not always show the selected control.
N/A

Workaround: N/A

Reported Version: 2012 SP1  Resolved Version: N/A  Added: 08/22/2016
562270

Return
The ADE generates incorrect browse information for a local function call if the function call result is cast using function pointer cast.
This can result in references to functions not being displayed by the source code browsing feature.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
564083

Return
The "glue code" for DLL functions generated by the Generate DLL Import Source feature does not have calling convention specified.
N/A

Workaround: Add the correct calling convention manually to each entry point.

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
568823

Return
CVI_AppSetSelection allows for selecting half characters on multibyte operating systems.
If you try to select a segment of code starting in the middle of a full-width character (i.e. spanning two columns) using the ActiveX function, LabWindows/CVI will allow this and will only partially copy the bytes corresponding to that character. (e.g. just the second byte of a two-byte character)

Workaround: Use copy/paste rather than the ActiveX function.

Reported Version: 8.0  Resolved Version: N/A  Added: 08/22/2016
570567

Return
The LabWindows/CVI ADE Distribution Installer Version Maximum version is 254.254.65534 instead of 255.255.65535
N/A

Workaround: N/A

Reported Version: 2010  Resolved Version: N/A  Added: 08/22/2016
574521

Return
The LabWindows/CVI ADE hangs when attempting to print and there are at least two printers, one of which has a Unicode symbol in its name, that doesn't have ANSI equivalent.
N/A

Workaround: N/A

Reported Version: 8.0  Resolved Version: N/A  Added: 08/22/2016
579855

Return
The Edit»Insert Construct»Function Documentation Tags feature does not generate documentation tags past a parameter that is a function pointer.
N/A

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
587239

Return
The graphical array view for arrays with 3 dimensions or more throws an exception.
When pressing Ctrl+ Shift + F4 ( Graphical array view ) on an array with 3 or more dimensions, two different popups appear:
First attempt: "A custom control callback raised an exception"
Subsequent attempts: "Panel, menu bar, or control array handle is invalid"

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
588343

Return
Samples that use assert_unreachable fail to compile from Visual Studio.
assert_unreachable is defined in LabWindows/CVI's assert.h, but when the sample is used from Visual Studio it uses its own header, which does not contain assert_unreachable .

Workaround: N/A

Reported Version: 2013 SP1  Resolved Version: N/A  Added: 08/22/2016
589439

Return
The Go to Definition function does not always store the initial cursor location.
If you have a function panel and associated .h and .c file, and function panel is added to the project, Go to Definition will take you to the declaration of the function in the header file and not the definition of it in the source file. If the function panel is not added to the project, Go to Definition will take you to the source file, if it is open. After taking you to this source file, LabWindows/CVI loses its initial cursor location and you can not select Go Back.

Workaround: N/A

Reported Version: 8.0  Resolved Version: N/A  Added: 08/22/2016
589445

Return
The Go to Definition menu item takes you to the incorrect location.
If you have a function panel and associated .h and .c file, and function panel is added to the project, Go to Definition will take you to the declaration of the function in the header file and not the definition of it in the source file. If the function panel is not added to the project, Go to Definition will take you to the source file, if it is open.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
589452

Return
CVI crashes when building a project if a Function Panel is present in the opened file section of the workspace file and the same Function Panel is loaded in the user libraries.
N/A

Workaround: Remove the Function Panel from the Library»Customize menu and restart LabWindows/CVI, or delete the workspace file.

Reported Version: 2013 SP2  Resolved Version: N/A  Added: 08/22/2016
592761

Return
The project appears to be modified after opening and closing the Manage Configurations dialog.
N/A

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
595232

Return
The UI Editor displays a The index passed is out of range error when cutting the last item in a menu bar.
N/A

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
533835

Return
The name of the exe is not changed on 64-bit configurations when renaming the project.
N/A

Workaround: N/A

Reported Version: 2009  Resolved Version: N/A  Added: 02/22/2017
537281

Return
Revert Tab command moves cursor but not text for a single line.
N/A

Workaround: Select multiple lines before executing Shift + Tab.

Reported Version: 2009  Resolved Version: N/A  Added: 02/22/2017
584096

Return
The Properties dialog of OpenGL plot cannot be closed after right-clicking on the plot when Properties dialog is already open.
N/A

Workaround: N/A

Reported Version: 8.0  Resolved Version: N/A  Added: 02/22/2017
586870

Return
Resource Tracking does not work properly when using Specify Executable and Command Line option.
When using the "Run»Specify Executable and Command Line" option to specify an executable to launch for debugging, and debug from CVI, resource tracking will not report cases where memory was allocated and not freed from DLLs.

Workaround: If you attach the CVI environment to an executable, resource tracking will work if you add the line SetEnableResourceTracking(1), but not if you start the application from CVI ADE.

Reported Version: 2015  Resolved Version: N/A  Added: 02/22/2017
588402

Return
An Internal error is thrown when using a distribution file with an unrecognized minimum .NET version.
If the .cds file has a minimum .NET version that the current version of CVI doesn't understand, it loads the distribution and the UI shows. However, when building the distribution, it gives only a generic error message without indication of the problem.

Workaround: Open Edit Distribution dialog and confirm dialog (no modifications required). This operation will overwrite the value passed down to MDF and will cause the distribution to build successfully.

Reported Version: 9.0  Resolved Version: N/A  Added: 02/22/2017
588406

Return
The SaveBitmapToTIFFile incorrectly returns Out of memory when destination file not found.
N/A

Workaround: N/A

Reported Version: 9.0  Resolved Version: N/A  Added: 02/22/2017
382558

Return
Opening a newer UIR file in a previous version of LabWindows/CVI and saving it can corrupt the UIR File.

Workaround: Save the UIR file for the previous version of LabWindows/CVI if you plan to use it in an older version.

Reported Version: 2012  Resolved Version: N/A  Added: 05/22/2017
383362

Return
Sometimes when extern is used in a variable declaration, Go to Definition highlights the declaration instead of the definition.
N/A

Workaround: Right click and select Browse Identifier. Refer to the Declarations in the identifier pane to see where in the project the variable is defined and where it is used as an extern.

Reported Version: 2013  Resolved Version: N/A  Added: 05/22/2017
388664

Return
Using Show Completions on a function that doesn't exist may result in other functions no longer appearing in the Show Completions list.
For example, if you have the function that begins with List, and you use the shortcut for Show Completions (control+space), you will see the functions associated with Lists. If you extend this to say ListFoo, you will notice that the list functions no longer appear in the menu.

Workaround: Delete the word and use Show Completions again with fewer characters.

Reported Version: 2012  Resolved Version: N/A  Added: 05/22/2017
399762

Return
Include statements dialog incorrectly adds include statements to multi-line comments.
LabWindows/CVI will detect that you are missing header files required for your project and prompt you to include them. If you have a multi-line comment that contains include statements, LabWindows/CVI will add the include statements to the multi-line comment instead of outside the comment.

Workaround: Add the required #include directives manually.

Reported Version: 2012  Resolved Version: N/A  Added: 05/22/2017
404335

Return
LabWindows/CVI may show an incorrect function prototype if it cannot resolve types in that function prototype
If you have a function defined in your source file whose prototype contains a type that LabWindows/CVI cannot resolve, then LabWindows/CVI will report that unresolved type as an int when you click Edit»View Prototype. LabWindows/CVI will also display the incorrect prototype if you try to use the function in your source file. The code will not compile until the symbol is resolved at which point LabWindows/CVI will show the correct prototype.

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 05/22/2017
408446

Return
Arrays of pointer type in function panels may not be recognized as arrays.
Depending on how the type is defined in the function panel, LabWindows/CVI may not recognize that the array of pointer type is actually an array. For example, if you create a type that has spaces between the square braces and the dereference operator i.e.char * [], then LabWindows/CVI will detect that this parameter is passed by reference which is untrue. This does not affect the functionality of the function panel.

Workaround: N/A

Reported Version: 8.0  Resolved Version: N/A  Added: 05/22/2017
525255

Return
Browse Information is not generated after editing an ActiveX Server from the Edit ActiveX Server Wizard.

Workaround: Disable and re-enable source code browsing in Options » Generate browse information policy. Alternatively, you can edit the source file you want regenerated.

Reported Version: 2013  Resolved Version: N/A  Added: 05/22/2017
Hardware
296666

Return
Regenerating DAQmx example code can sometimes fail to regenerate code.
If you change acquisition mode from "Every N Samples" to "Continuous Samples", the example code may not regenerate.

Workaround: Regenerate the code from the source file instead of the header file.

Reported Version: 2010  Resolved Version: N/A  Added: 07/30/2011
Installer
128084

Return
Uninstalling LabWindows/CVI from Windows Vista does not completely remove context menu file associations.

Workaround: N/A

Reported Version: 9.0  Resolved Version: N/A  Added: 05/05/2010
309196

Return
Uninstalling LabWindows/CVI or a distribution containing the LabWindows/CVI Side-By-Side Run-Time Engine does not remove some components from the Windows side-by-side directory.
Some components are left installed in the C:\Windows\winsxs directory. This is expected behavior of the Windows operating system.

Workaround: Do not remove these files manually. The files will eventually be removed automatically by Windows.

Reported Version: 2012  Resolved Version: N/A  Added: 02/27/2013
Linux
162307

Return
Cannot set the active tab page after deleting a tab.

Workaround: N/A

Reported Version: 8.0  Resolved Version: N/A  Added: 09/17/2010
Performance
144640

Return
LabWindows/CVI MAX_PATHNAME_LEN is more restrictive than Windows ANSI path limitation in multibyte systems.

Workaround: N/A

Reported Version: 7.1.1  Resolved Version: N/A  Added: 05/05/2010
176800

Return
LabWindows/CVI projects converted to Microsoft Visual C++ 2005 projects fail to build because of link errors.
Link errors such as

cvisupp.lib(setprec.obj) : fatal error LNK1103: debugging information corrupt; recompile module

and

cviauto.lib(implib.obj) : fatal error LNK1103: debugging information corrupt; recompile module

are indications your projects are affected by this problem.

Workaround: Apply the VS2005 SP1 hotfix included for KB949009.

Reported Version: 2009  Resolved Version: N/A  Added: 05/05/2010
41414

Return
A small memory leak exists in network variable creation.
Explicitly creating network variables results in a memory leak of approximately 50 bytes per variable that is created.

Workaround: Consider using implicitly created network variables if you are creating and deleting numerous network variables over a long period of time.

Reported Version: 8.5  Resolved Version: N/A  Added: 05/05/2010
256901

Return
Passing a pointer to a custom data type to a function that takes a void * will leak memory in a debug build.
LabWindows/CVI user protection leaks memory when a pointer to a user defined data type is passed to a function with a void * parameter. An example of this would be calling the function ListInsertItem and passing a pointer to a user defined data type to the PointerToItem parameter.

Workaround: Disable user protection, or build the program in a Release configuration.

Reported Version: 9.0  Resolved Version: N/A  Added: 11/15/2010
281013

Return
Calling DDC_SaveFile often while creating a TDMS file using the TDM C DLL or the DDC Library can result in errors.
Depending on when DDC_SaveFile is called, you might receive error -6218 or error -6226.

Workaround: Don't call DDC_SaveFile until all operations are complete.

Reported Version: 2010  Resolved Version: N/A  Added: 03/09/2011
257029

Return
The LabWindows/CVI Run-Time Engine creates windows in its DLL_PROCESS_ATTACH handler.
When the LabWindows/CVI Run-Time Engine loads, it creates multiple windows in its DLL_PROCESS_ATTACH handler. This is generally discouraged practice, but has not been known to cause problems in user applications.

Workaround: Do not call the Win32 API functions LoadLibrary and FreeLibrary to load and unload a LabWindows/CVI built DLL from different threads.

Reported Version: 2009  Resolved Version: N/A  Added: 03/10/2011
457464

Return
Passing a bitmap file containing negative heights to PlotBitmap or GetBitmapFromFile causes a non-fatal run-time error: Library function error (return value == -12 [0xfffffff4]). Out of memory.

Workaround: Modify the bitmap file header to have a positive height, reorder the pixels, and save the file.

Reported Version: 7.0  Resolved Version: N/A  Added: 03/28/2014
460818

Return
SMTP servers reject email from InetSendMail because it does not send date information in the header.

Workaround: N/A

Reported Version: 5.5  Resolved Version: N/A  Added: 03/28/2014
371953

Return
The intensity plot does not handle NaN values.

Workaround: Handle NaN values before passing the data to PlotScaledIntensity.

Reported Version: 4.0  Resolved Version: N/A  Added: 05/07/2014
405988

Return
Changing the active table cell can incorrectly send the EVENT_ACTIVE_CELL_CHANGE event multiple times.
If, inside a callback function that handles EVENT_ACTIVE_CELL_CHANGE, you do something to change the focus of the panel (for example, displaying a message popup), the event is sent a second time after the callback finishes executing.

Workaround: You can use the following code to handle the second, incorrectly sent event.

void CVICALLBACK FlagClearFunc (void *callbackData)

{

*(int *)callbackData = 0;

}



int CVICALLBACK TableCB (int panel, int control, int event, void *callbackData,



int eventData1, int eventData2)

{

static int ignoreNextEvent = 0;



switch (event)

{

case EVENT_ACTIVE_CELL_CHANGE:

if (!ignoreNextEvent)

MessagePopup ( "title", "message" );

ignoreNextEvent = 1;

PostDeferredCall (FlagClearFunc, &ignoreNextEvent);

break;

}

return 0;

}

Reported Version: 8.0  Resolved Version: N/A  Added: 05/07/2014
408097

Return
Passing a scalar value as the mask parameter of PlotPackedDigitalLines causes a general protection fault.

Workaround: Ensure the mask value you provide has a data type that matches what you have specified for the dataType parameter.

Reported Version: 7.1  Resolved Version: N/A  Added: 05/07/2014
424944

Return
Creating a .NET controller for a large assembly, such as Microsoft.mshtml, appears to cause a hang but eventually completes successfully.

Workaround: N/A

Reported Version: 8.0  Resolved Version: N/A  Added: 05/07/2014
429320

Return
InetFTPGetDirList returns 0 on certain FTP servers despite the presence of files.



Reported Version: 2009 SP1  Resolved Version: N/A  Added: 05/07/2014
382850

Return
The NIReport_Print function hangs on Windows 8 when you select Microsoft XPS Document Writer as the printer.

Workaround: N/A

Reported Version: 2009  Resolved Version: N/A  Added: 08/22/2014
511573

Return
Scrolling through a table control containing thousands of images may cause a General Protection Fault.
A fatal run-time error with the message General Protection Fault may occur if you create a table control with 10,0000 or more images and attempt to scroll through it.

Workaround: It is recommended to use fewer rows when displaying images in a table control. If it is necessary to store a large number of images, you could store them in a data structure such as an array and populate a table control with a subset of the images as needed.

Reported Version: 2012  Resolved Version: N/A  Added: 08/03/2015
417963

Return
The compiler crashes when compiling a file that contains assembler instructions with C expression operands.
N/A

Workaround: N/A

Reported Version: 2013  Resolved Version: N/A  Added: 08/22/2016
579557

Return
The LabWindows/CVI Runtime does not support callback function names containing dollar ($) signs.
Using dollar signs in callback function names results in a non-fatal run-time error or an error at run time which reads like the following: callback function, <function name>, specified in the UIR file, is not a known function.

Workaround: Do not use the '$' character in the names of callback functions.

Reported Version: 8.0  Resolved Version: N/A  Added: 08/22/2016
593193

Return
The Translate From Dictionary feature of the User Interface Localizer Tool fails to translate all items in a UIR file containing a large number of subpanels.
N/A

Workaround: N/A

Reported Version: 2009  Resolved Version: N/A  Added: 08/22/2016
Stand-Alone Applications and Distributions
186565

Return
LabWindows/CVI distributions cannot install fonts on Windows Vista or Windows 7.

Workaround: N/A

Reported Version: 8.5  Resolved Version: N/A  Added: 05/05/2010
309112

Return
LabWindows/CVI 8.0 distributions cannot include the ActiveX container merge module if LabWindows/CVI 2009 or later is installed on the same system.
This issue occurs because the name of the merge module changed in LabWindows/CVI 2009, and LabWindows/CVI 8.0.x attempted to find merge modules by name.

Workaround: Create a copy of C:\Program Files (x86)\Common Files\Merge Modules\ActiveX_Container.msm and rename the copy to C:\Program Files (x86)\Common Files\Merge Modules\ActiveX Container.msm.

Reported Version: 2009  Resolved Version: N/A  Added: 07/28/2011
354481

Return
User specified icons are not displayed in Windows Explorer for larger sizes in Windows Vista/7.
In certain situations, the icon displayed may be a cached icon rather than the icon you have specified.



Reported Version: 8.5  Resolved Version: N/A  Added: 07/22/2012
440951

Return
When building a 64-bit installer, there is no installation directory option for LabVIEW (64-bit).
When specifying Installation Files & Directories in the Edit Installer dialog box, you can choose [LabVIEW], but there is no option for [LabVIEW (64-bit)].

Workaround: When creating the installer, select [NationalInstruments] as the root for the component, and create the LabVIEW directory hierarchy underneath that directory.

Reported Version: 2009  Resolved Version: N/A  Added: 12/12/2013
442334

Return
Application hangs may occur when panning a graph outside the double data range.
N/A

Workaround: N/A

Reported Version: 8.5  Resolved Version: N/A  Added: 08/22/2016
442335

Return
Application hangs may occur when zooming a graph with log scale outside the double data range.
N/A

Workaround: N/A

Reported Version: 9.0  Resolved Version: N/A  Added: 08/22/2016
User Interface
126708

Return
PlotArc lacks accuracy for drawing a small angle with a large radius.

Workaround: N/A

Reported Version: 8.5.1  Resolved Version: N/A  Added: 05/05/2010
140926

Return
Changing the axis range on a LabWindows/CVI graph plot with few points causes skewed plot lines.
Due to rounding errors, as points move further off screen, the plot lines become less accurate.

Workaround: Provide more points for your plot, or constrain the range of the graph in question.

Reported Version: 5.5  Resolved Version: N/A  Added: 05/05/2010
193088

Return
If a LabWindows/CVI popup panel is not active, subsequent popup panels may appear behind the original popup panel.
This issue only occurs on Windows 7/Vista.

Workaround: N/A

Reported Version: 6.0  Resolved Version: N/A  Added: 05/05/2010
193403

Return
The panel attribute ATTR_MOVABLE does not work with Aero enabled on Windows 7/Vista.

Workaround: N/A

Reported Version: 9.0  Resolved Version: N/A  Added: 05/05/2010
194450

Return
LabWindows/CVI windows do not support Aero Shake.
Shaking the title bar of the LabWindows/CVI environment or LabWindows/CVI panels or pressing <Windows-Home> when a LabWindows/CVI window is active does not minimize other open windows. When Aero is enabled in Windows 7, the other windows should be minimized by the Aero Shake feature.

Workaround: N/A

Reported Version: 2009  Resolved Version: N/A  Added: 05/05/2010
209745

Return
Very large maximum stack sizes cause the "My Documents" button of LabWindows/CVI file select popup panels to fail.
After you click the My Documents button, only a white background displays. Your drives and network locations will not display.

Workaround: Reduce the maximum stack size.

Reported Version: 2009  Resolved Version: N/A  Added: 05/05/2010
303637

Return
Scrolling strip charts can have inaccurate values for min and max due to rounding errors.
For example, if your strip chart displays 100 points and you plot 100 points at a time, the end values may end with a value other than 99.

Workaround: N/A

Reported Version: 6.0  Resolved Version: N/A  Added: 07/27/2011
293672

Return
Some user interface controls do not draw Windows styles on mouse-over.
For example, the following controls and control parts should display as a highlighted blue on Windows Vista and later, but do not:
  •  
  • The inc/dec arrows for all numeric controls.
  •  
  • The square push button and the square text button.
  •  
  • The list control scroll bar arrows and thumb.
  •  


Workaround: N/A

Reported Version: 8.5  Resolved Version: N/A  Added: 08/01/2011
292070

Return
Passing TRUE to the RestrictDirectory parameter of FileSelectPopup does not completely restrict the directory to the initial directory.
The user can select files from other directories by entering the path directly into the File Name control and by selecting a file from the previously selected files drop-down list.

Workaround: N/A

Reported Version: 6.0  Resolved Version: N/A  Added: 08/02/2011
37666

Return
Panels displayed with ATTR_WINDOW_ZOOM set to VAL_MAXIMIZE will not restore after showing the desktop.
You can show the desktop by pressing <Windows Key-D> or by selecting the Show Desktop button on the task bar.

Workaround: Call SetPanelAttribute with ATTR_WINDOW_ZOOM after calling DisplayPanel.

Reported Version: 8.0  Resolved Version: N/A  Added: 08/02/2011
314106

Return
The x-axis of the digital graph displays improper divisions.
Large digital graphs with engineering or scientific display format set for the x-axis may display divisions and division labels that are inconsistent with other display formats.

Workaround: N/A

Reported Version: 8.0  Resolved Version: N/A  Added: 01/11/2012
316397

Return
Saving a file with the FileSelectPopup function displays a "file already exists" error when another file with the same basename and no extension exists in the selected directory.
The file is saved despite the error.

Workaround: N/A

Reported Version: 2010  Resolved Version: N/A  Added: 02/15/2012
329405

Return
Numeric control radix does not resize with control text size.
N/A

Workaround: N/A

Reported Version: 3.0  Resolved Version: N/A  Added: 03/23/2012
335982

Return
MultiFileSelectPopupEx cannot select multiple files if the first file in the list does not exist and the second file does.
The selection error occurs only if the first file in the selection list does not exist and an existing file appears later in the list.

Workaround: Ensure that the first file in the selection list exists.

Reported Version: 2012  Resolved Version: N/A  Added: 07/17/2012
351981

Return
Dimming ActiveX control does not terminate mouse tracking.
This behavior can cause problems if you dim the ActiveX control while doing a click and drag operation on the control. In this scenario, the mouse interaction continues even after the control is dimmed.

Workaround: N/A

Reported Version: 2010  Resolved Version: N/A  Added: 07/17/2012
337950

Return
Graph zoom selection box leaves artifacts if a control is moved over the drawing region in between frames.
If a control is moved over the graph's drawing region while creating a zoom selection box, the control may interfere with the drawing of the selection box and leave traces of where the selection box once was.

Workaround: N/A

Reported Version: 8.5  Resolved Version: N/A  Added: 07/22/2012
347056

Return
Dragging the ring tank control value to change its fluid height at run-time may cause black lines to appear where the previous fluid height was.

Workaround: N/A

Reported Version: 9.0  Resolved Version: N/A  Added: 07/22/2012
349832

Return
The mouse wheel scrolls the wrong control while ring control menu is displayed.
This behavior occurs if the focus is still on a different control when the ring drop-down menu is opened.

Workaround: N/A

Reported Version: 8.1  Resolved Version: N/A  Added: 07/22/2012
350412

Return
In some cases, the EVENT_LOST_FOCUS and EVENT_COMMIT events are not displayed in Operate mode when changing focus away from controls.

Workaround: N/A

Reported Version: 8.5  Resolved Version: N/A  Added: 07/22/2012
350752

Return
A tree item tooltip continues to display when the cursor is over a tree item and another active window is in front of part of the tree item.

Workaround: N/A

Reported Version: 8.5  Resolved Version: N/A  Added: 07/22/2012
350944

Return
The numeric control cannot have a transparent background.

Workaround: N/A

Reported Version: 6.0  Resolved Version: N/A  Added: 07/22/2012
241929

Return
Ctrl-Tab and Ctrl-Alt-Tab on Tab Control does not generate an EVENT_KEYPRESS event if another control has focus.
This is because Ctrl-Tab and Ctrl-Alt-Tab are built in hotkeys for the tab control. These events are swallowed by the Tab control before the user receives them.

Workaround: N/A

Reported Version: 8.5  Resolved Version: N/A  Added: 02/27/2013
413695

Return
Radial controls do not resize all elements proportionally.
Some controls will not scale all elements proportionally when the Scale Contents On Resize panel option is enabled and they are resized. Radial controls such as the gauge, meter, and knob must maintain a consistent aspect ratio for the radial portion of the control. However, this is not necessary for some elements of the control such as the label. These elements will not be scaled the same. This can cause elements to become misaligned or overlap.

Workaround: Use the splitter control to resize controls rather than the Scale Contents On Resize option. Refer to the docking.cws example for details on how to accomplish this with splitter controls.

Reported Version: 5.0  Resolved Version: N/A  Added: 08/05/2013
369944

Return
The canvas control creates some undesired artifacts when rotated or moved around.

Workaround: N/A

Reported Version: 9.0  Resolved Version: N/A  Added: 05/07/2014
382278

Return
The save button cannot be used in the Attribute Browser toolbar.

Workaround: To save changes made in the Attribute Browser, use File»Save or <Ctrl-S>.

Reported Version: 2010  Resolved Version: N/A  Added: 05/07/2014
404129

Return
After rotating the markers of a gauge control, the needle becomes misaligned with the center of the gauge.

Workaround: N/A

Reported Version: 9.0  Resolved Version: N/A  Added: 05/07/2014
421591

Return
Active tooltips do not update when the tooltip text changes programmatically.

Workaround: N/A

Reported Version: 2012  Resolved Version: N/A  Added: 05/07/2014
423072

Return
The two panel attributes, ATTR_HEIGHT and ATTR_WIDTH, cannot be sized beyond a certain value, which depends on monitor resolution.

Workaround: Use a child panel, which does not have the same height and width limitations.

Reported Version: 9.0  Resolved Version: N/A  Added: 05/07/2014
427065

Return
The maximum window size is limited by screen resolution.
This maximum value is imposed during the LabWindows/CVI WM_GETMINMAXINFO message handler.

Workaround: Intercept the WM_GETMINMAXINFO message and change the maximum values as demonstrated in the following code snippet:

//Custom window procedure

static LRESULT CALLBACK MsgrWndProc (HWND hwnd, UINT message, WPARAM wParam, LPARAM lParam )

{

switch(message)

{

case WM_GETMINMAXINFO:

{

if(largeSize)

{

//Modify lParam such that it uses the correct sizes

MINMAXINFO FAR *lpmmi = (MINMAXINFO FAR*)lParam;

lpmmi->ptMaxTrackSize.y = customHeight;

lpmmi->ptMaxTrackSize.x = customWidth;



largeSize = 0;



//Return 0 to swallow the event

return 0;

}

}

}



//Call the default window procedure and pass it the parameters passed to it

return CallWindowProc((WNDPROC)DefaultWndProc, hwnd, message, wParam, lParam);

}

Reported Version: 7.0  Resolved Version: N/A  Added: 05/07/2014
431566

Return
In the User Interface Editor, if you rotate a text message that has the Size to text option disabled, the resulting text message is drawn incorrectly, selected incorrectly, and inoperable.

Workaround: N/A

Reported Version: 9.0  Resolved Version: N/A  Added: 05/07/2014
432165

Return
Under specific graph setting conditions, the fat line plot style renders incorrectly.
Instead of a solid line, the line appears half solid, half broken.

Workaround: Disable anti-aliasing or y-axis labels, or add a plot legend. Resizing the graph sometimes resolves the rendering issue.

Reported Version: 2009  Resolved Version: N/A  Added: 05/07/2014
437605

Return
Graphs containing multiple plots with different plot styles show incorrect plot styles in the graph legend.

Workaround: Obtain the plot style programmatically.

Reported Version: 9.0  Resolved Version: N/A  Added: 05/07/2014
439046

Return
Toolbar click events do not cause numeric controls to leave edit mode.
If you are editing a control using the keyboard and subsequently click a toolbar menu item, the control does not commit the edit before the toolbar menu item click event is processed. If the control loses focus, the edit is committed.

Workaround: Commit control edits by calling SetActiveCtrl (GetActivePanel (), GetActiveCtrl (GetActivePanel ())); before reading the control value.

Reported Version: 9.0  Resolved Version: N/A  Added: 05/07/2014
460638

Return
The picture command button can incorrectly show the resizing frame when the Size control to image Fit mode is selected.
The picture command button should not be allowed to change dimensions in this mode.

Workaround: Close and reopen the UIR file.

Reported Version: 8.0  Resolved Version: N/A  Added: 05/07/2014
391647

Return
Changing focus from the graph control while you operate a cursor inside the control leaves the cursor at an intermediate position.

Workaround: N/A

Reported Version: 2009  Resolved Version: N/A  Added: 08/22/2014
402602

Return
The graph control plot can change size when the graph control changes size, even when the Fixed Plot Area attribute (ATTR_FIXED_PLOT_AREA) is enabled.

Workaround: Track the plot area and restore it after a graph control resize operation causes the plot area to change.

Reported Version: 9.0  Resolved Version: N/A  Added: 08/22/2014
424549

Return
The default values for the ATTR_HIDE_HILITE and ATTR_HILITE_ONLY_WHEN_PANEL_ACTIVE attributes do not persist for table controls when set in the UIR file.

Workaround: Set the values programmatically using SetCtrlAttribute.

Reported Version: 2009  Resolved Version: N/A  Added: 08/22/2014
461922

Return
Enabling Show Grid and Auto Divisions in the Edit Axis Settings dialog box for the right y-axis causes incorrect x-axis tick marks to appear.
Enabling these settings for the left y-axis does not result in incorrect tick marks.

Workaround: Uncheck Auto Divisions in the Edit Axis Settings dialog box for the right y-axis and change the Divisions setting to a specific number.

Reported Version: 2012  Resolved Version: N/A  Added: 08/22/2014
470189

Return
Resizing a knob control by operating a splitter control causes the digital display of the knob control to be positioned at the wrong coordinates.

Workaround: N/A

Reported Version: 8.0  Resolved Version: N/A  Added: 08/22/2014
484206

Return
The image quality of some images loaded in a picture command button degrades after saving and loading the user interface file multiple times.
Reduction of quality is noticeable after 10 saves.

Workaround: Reload the original image from disk. You can do this programmatically by setting the ATTR_IMAGE_FILE attribute with SetCtrlAttribute.

Reported Version: 9.0  Resolved Version: N/A  Added: 08/22/2014
489628

Return
Displaying a floating point number with more than 16 digits may cause the number to be displayed in scientific notation.
When a floating point number with more than 16 digits is displayed in a numeric control with 2 digits of precision, the value will be displayed in scientific notation. For example, 1E-16 will display as 0.00, but 1E-17 will display as 1E-17.

Workaround: If the value you are displaying in the numeric control is smaller than 1.0E-17, write a zero to the numeric control instead of the original value.

Reported Version: 2013  Resolved Version: N/A  Added: 08/03/2015
494678

Return
EVENT_COMMIT is not raised when focus is changed from a table cell in edit mode to a different user interface panel.

Workaround: Use a different event, such as EVENT_EDIT_MODE_STATE_CHANGE, to instruct your application to react to the table cell losing focus.

Reported Version: 9.0  Resolved Version: N/A  Added: 08/03/2015
498977

Return
Graph axis divisions may not be plotted when axis scale is set to certain values.
This issue only occurs for certain axis scales. Data is correctly plotted on the graph, but the axis division markers are not displayed.

Workaround: Change the axis scale to force the axis division markers to be plotted.

Reported Version: 2009  Resolved Version: N/A  Added: 08/03/2015
514898

Return
LabWindows/CVI does not mark the UIR file as modified after changing the Frame Color of a decoration, which results in changing the Conform to System Color and Conform to System Theme panel attributes.

Workaround: Make an additional change to the panel and explicitly save the UIR file to commit the changed attributes to the UIR file.

Reported Version: 2010  Resolved Version: N/A  Added: 08/03/2015
526939

Return
You cannot directly change the tab order of initially dimmed controls in the Edit Tabbing Order dialog by clicking the dimmed controls.

Workaround: Set the tab order of controls before enabling Initially dimmed.

Reported Version: 2012  Resolved Version: N/A  Added: 08/03/2015
415857

Return
The table attribute ATTR_FIRST_VISIBLE_ROW does not work in some cases.
N/A

Workaround: Set the active table cell using the SetActiveTableCell function before setting the table attribute ATTR_FIRST_VISIBLE_ROW.

Reported Version: 2012 SP1  Resolved Version: N/A  Added: 08/22/2016
438150

Return
A previously selected control may retain focus after subsequently attempting to operate a Ring control.
When selecting a Ring control, the previously selected control is able to be operated using the mouse scroll wheel. This behavior will continue until an item in the Ring control is selected. This behavior will occur again for any new selection of a Ring control after a previously selected control had focus.

Workaround: N/A

Reported Version: 8.0  Resolved Version: N/A  Added: 08/22/2016
440980

Return
When zooming a graph with log scale on the y-axis, the y-axis label displays too many decimal digits.
N/A

Workaround: N/A

Reported Version: 8.5  Resolved Version: N/A  Added: 08/22/2016
545203

Return
When a user interface application uses SetMouseCursor to set the mouse style to VAL_POINTING_FINGER_CURSOR, and the panel contains a HyperLink Toolslib custom control, the custom control issues a 'The mouse cursor passed is not valid' library function error.

Workaround: Initialize the cached cursor in the HyperLink custom control Initialize function with the current cursor:

<pre>GetMouseCursor (&cursor);
SetTsvCursor (cursor);</pre>

Reported Version: 9.0  Resolved Version: N/A  Added: 08/22/2016
556606

Return
Tooltips can be clipped by bottom edge of monitor.
N/A

Workaround: N/A

Reported Version: 2012  Resolved Version: N/A  Added: 08/22/2016
590484

Return
The Strip Chart axis label angle changes when the panel is resized.
Re-sizing a LabWindows/CVI UI with a Strip Chart with one axis' Label Angle set to any value other than 0 will cause the other axis to adopt that angle after the window resize completes. This behavior requires that the "Scale Contents on Resize" and the "Sizeable" attributes are checked for the panel.

Workaround: 1. Use a panel callback and handle EVENT_PANEL_SIZE event
2. Apply the original y-axis angle in the event case

Reported Version: 2015  Resolved Version: N/A  Added: 08/22/2016

 

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).