ID | Known Issue |
---|
157577
Return | Instrument I/O Assistant code generation fails when the FIPS algorithm policy is enabled.
The Instrument I/O Assistant fails to generate code in Measurement Studio for Visual Studio 2005 and Visual Studio 2008 when the FIPS (Federal Information Processing Standards) algorithm policy is enabled on a machine.
Workaround: 1. Disable the FIPS algorithm policy on the machine.
2. Open or restart Visual Studio 2005 or Visual Studio 2008 and re-generate code in the Instrument I/O Assistant.
3. Re-enable the FIPS algorithm policy on the machine.
See this Microsoft KB for more information.
Reported Version: 4.5 | | Resolved Version: N/A | | Added: 04/30/2009 |
|
105956
Return | Viewing NI-VISA Options tab on Real-Time controller may hang MAX
On PXI and PC Real-Time controllers with VISA Server installed, MAX occasionally may hang when trying to view the VISA Options tab.
Workaround: N/A
Reported Version: 4.3 | | Resolved Version: N/A | | Added: 08/25/2010 |
|
109538
Return | Slot path shows up incorrectly for multifunction and bridged NI-VISA-based PXI devices
PXI devices that are either behind a PCI bridge or have multiple functions (for example, both Ethernet and SCSI device) show an incorrect slot path in MAX when using a driver generated by the VISA Driver Development Wizard.
Workaround: N/A
Reported Version: 4.3 | | Resolved Version: N/A | | Added: 08/25/2010 |
|
126535
Return | VISA Read STB on Mac OS X waits for NI-VISA-defined timeout even if USB device responds sooner
VISA Read STB always waits for the timeout defined in NI-VISA before returning, even if a USB device returns a response quicker than the timeout value.
Workaround: N/A
Reported Version: 4.4 | | Resolved Version: N/A | | Added: 08/25/2010 |
|
145966
Return | Third-Party USB device communication may timeout after host PC is put into standby
A Windows-based machine communicating with a third-party USB device using a driver not developed by the VISA Driver Development Wizard may timeout if the PC is put into standby mode in the middle of a NI-VISA USB transfer. After the PC is woken up, it thinks the USB device should resend the entire data packet and eventually times out because the packet is not resent.
Workaround: N/A
Reported Version: 4.4 | | Resolved Version: N/A | | Added: 08/25/2010 |
|
166323
Return | Using interrupts with NI-VISA-based PXI cards on NI RT Hypervisor system may cause hang on reboot
If you are using interrupts with a PXI card that uses an NI-VISA-based driver on an NI RT Hypervisor system, independent reboot of the RT system may hang if the driver does not have the interrupt disarm sequence defined.
Workaround: N/A
Reported Version: 4.5.1 | | Resolved Version: N/A | | Added: 08/25/2010 |
|
183242
Return | Calling viUsbControlIn on composite USB devices may cause system to blue screen
When using viUsbControlIn or VISA USB Control In.vi, if a composite USB RAW device is passed in as the VISA resource, the system may crash with a blue screen.
Workaround: N/A
Reported Version: 4.6 | | Resolved Version: N/A | | Added: 08/25/2010 |
|
226865
Return | Drivers developed by the VISA Driver Development Wizard on Windows XP Dutch do not install correctly
When using the VISA Driver Development Wizard on Windows XP Dutch, the OS does not correctly recognize the .inf file generated.
Workaround: N/A
Reported Version: 3.4 | | Resolved Version: N/A | | Added: 08/25/2010 |
|
90238
3WP9E800
Return | NI-VISA leaks Mach ports on Mac OS X when communicating with USB Raw devices
When performing a VISA Open and VISA Close on a USB Raw device multiple times inside a loop, the number of Mach ports in Mac OS X increases. This may cause a crash if the code performing these calls is run over an extended period of time.
Workaround: Restart the development/run-time environment
Reported Version: 3.4 | | Resolved Version: 4.5 | | Added: 08/25/2010 |
|
255456
Return | Two applications simultaneously calling viLock and viUnlock on the same VISA INSTR resource will eventually result in an error
Two applications that are both trying to lock and unlock a VISA INSTR resource using viLock and viUnlock will result in one of the applications eventually returning error -1073807204: VISA: (Hex 0xBFFF009C) The current session did not have a lock on the resource.
Workaround: N/A
Reported Version: 5.0.1 | | Resolved Version: N/A | | Added: 08/09/2011 |
|
283686
Return | Rebooting a system or refreshing Devices & Interfaces in MAX will remove a key in visaconf.ini
If the following key is added to disable the error replacement character when performing 9-bit VISA serial reads, refreshing Devices & Interfaces in MAX or rebooting the system will remove that key from visaconf.ini:
[ASRL-RSRC-ALIAS]
DisableErrorReplacement=1
Workaround: N/A
Reported Version: 5.0 | | Resolved Version: N/A | | Added: 08/09/2011 |
|
308006
Return | Providing VISA remote access to a cRIO device may cause duplicate Serial & Parallel entries in MAX
Adding a new permission to the Remote Access List under the VISA Server for a cRIO device may cause duplicate Serial & Parallel entries to appear underneath the device in MAX.
Workaround: N/A
Reported Version: 4.6 | | Resolved Version: N/A | | Added: 08/09/2011 |
|
412663
Return | VISA Interactice Control help cannot be opened on Linux computers
Workaround: N/A
Reported Version: 5.4 | | Resolved Version: N/A | | Added: 09/06/2013 |
|
366314
Return | TCP VISA Read/Write calls have 2000 ms timeout.
If you pass an invalid TCP resource to VISA Read or VISA Write, the call will take 2000 ms to timeout. This occurs regardless of the timeout value originally specified with the VISA Set Timeout call.
Workaround: N/A
Reported Version: Unknown | | Resolved Version: N/A | | Added: 08/04/2014 |
|
475562
Return | Only serial aliases are returned with I/O Name Filtering in LabVIEW 32-bit.
When using I/O Name Filtering with Include these Aliases set to All defined aliases for resources of this class, LabVIEW 32-bit only returns serial aliases. For LabVIEW 64-bit, all defined aliases are returned.
Workaround: Set the aliases with MAX.
Reported Version: 14.0 | | Resolved Version: N/A | | Added: 08/04/2014 |
|
491750
Return | The viStatusDesc function in LabWindows/CVI may return an incorrect status value when built in 64-bit configuration
The viStatusDesc function in LabWindows/CVI may incorrectly report "VI_SUCCESS" for unknown error codes instead of returning "VI_WARN_UNKNOWN_STATUS" when built in 64-bit configuration.
Workaround: N/A
Reported Version: Unknown | | Resolved Version: N/A | | Added: 08/03/2015 |
|
523556
Return | NI-VISA may return error 0xBFFF003A (VI_ERROR_INV_SETUP) when enumerating Keysight devices
In some cases, NI-VISA will return error 0xBFFF003A (VI_ERROR_INV_SETUP) when attempting to enumerate Keysight devices. This occurs because both the Tulip and Serial passports return duplicate information about the devices.
Workaround: Disable either the Tulip or Serial passport.
Reported Version: 14.0.1 | | Resolved Version: N/A | | Added: 08/03/2015 |
|
536772
Return | Connection to HiSLIP devices may be dropped if HiSLIP data message contains MessageID parameter of 'None' (0xFFFFFFFF)
If NI-VISA receives a HiSLIP data message with a MessageID parameter of 'None' (0xFFFFFFFF), it will drop the connection to the HiSLIP device.
Workaround: N/A
Reported Version: 15.0 | | Resolved Version: N/A | | Added: 08/03/2015 |
|
543928
Return | Extra 0xFF characters may be received when using NI-VISA to read from serial ports on Linux RT targets
There is a known issue with the Linux kernel used in LabVIEW Real-Time 2013 and 2014. It can cause extra 0xFF characters to be returned by a call to VISA Read on a serial port. For more information, go to ni.com/info and enter Info Code NIVISA1501Update_en.
Workaround: N/A
Reported Version: 5.4 | | Resolved Version: 15.0.1 | | Added: 11/03/2015 |
|
569122
Return | VisaNS Runtime Appears Twice in Measurement Studio Installer Builder
Measurement Studio Installer Builder may display two duplicate options for including the VisaNS runtime in the installer.
Workaround: Choose one of the instances of the VisaNS runtime, and it will be correctly included in your installer.
Reported Version: 15.5 | | Resolved Version: N/A | | Added: 3/9/2016 |
|