NI CompactRIO Device Drivers August 2016 and NI R Series MultifunctionRIO August 2016 Bug Fixes

Overview

The following items are a subset of issues fixed in NI CompactRIO Device Drivers August 2016 and NI R Series Multifunction RIO Device Drivers August 2016 since NI CompactRIO Device Drivers February 2016 and NI R Series Multifunction RIO Device Drivers February 2016. If you have an issue ID, you can search this list to validate that the issue has been fixed in NI CompactRIO Device Drivers August 2016 or NI R Series Multifunction RIO Device Drivers August 2016 with LabVIEW 2016.

 

IDFixed Issue

389839

Scanning memory within a process that uses R Series devices can cause a crash or data corruption. Refer to KB 6CBD88VQ for more information.

529182

NI-XNET modules do not show up as supported Scan Interface modules on cRIO-903x controllers in a LabVIEW 2015 project.

531415

The RT LED.vi behavior was inconsistent with documentation for the following controllers: cRIO-9063, cRIO-9064, cRIO-9065, cRIO-9066, cRIO-9067, and sbRIO-9651.

559661

The Signal Quality Property Node is not supported for the cRIO-9032 and cRIO-9037 targets in LabVIEW 2015 SP1.

564308

Scan Interface timing fault -65512 occurs on cRIO-908x controllers configured for low scan frequencies of about 10 Hz.

565604

The property for disabling an open thermocouple error in Scan Interface is not visible in the NI 9213 Module Properties dialog box.

577458

User defined variables (UDVs) timestamping functionality does not work if no modules are used in Scan Interface.

581408

A timing violation occurs when running a single-cycle timed loop with a different clock than the top level clock. This issue affects only targets that require a Vivado compiler. Visit ni.com/info and enter the Info Code XilinixCompileTools to determine if your target uses a Vivado compiler.

589971

MDK modules with names in software that contain spaces fail to load in LabVIEW 2015 SP1.

 

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).