This document contains the MAX 16.0 and NI System Configuration 16.0 known issues that were discovered before and since the previous release. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.
Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community.
This document contains the MAX 16.0 and System Configuration 16.0 known issues that were discovered before and since the release NI System Configuration 16.0. Not every issue known to NI will appear on this list; it is intended to only show the severe and common issues.
The following items are known issues in MAX 16.0 and NI System Configuration 16.0 KIL sorted by Date.
ID | Known Issue | |||||
---|---|---|---|---|---|---|
598531 Return | MAX 16.0 shows "Inconsistent IP Settings" for remote systems and is missing local network adapters on the Network Adapters tab for My System. MAX 16.0 shows "Inconsistent IP Settings" for remote systems and is missing local network adapters on the Network Adapters tab for My System. Workaround: Upgrade to MAX to 16.0.1 using NI System Configuration 16.0.1 or update to the NI System Configuration 16.0.1 Run-Time Engine
| |||||
587104 Return | Setting time and timezone together fails on Linux ARM cRIOs When setting the current time and timezone together in MAX or the WIF, a Linux ARM cRIO will fail to correctly set the current time. Workaround: Save the timezone and time in two different steps or put the target in the UTC timezone, save, and then change both the timezone and time.
| |||||
586003 Return | Installing/Uninstalling Real-Time software components to Real-Time targets in MAX fails when LabVIEW Real-Time Software is installed to path with non-English characters Users are unable to install/uninstall Real-Time software components using the Real-Time Software Wizard in MAX when LabVIEW Real-Time Software is installed to a path with non-English characters, such as a path Japanese characters. Workaround: Install LabVIEW Real-Time Software to default path.
| |||||
559781 Return | System Configuration Restart.vi throws error -2147220309 after setting a Real-Time target to a static IP address on Mac When setting a static IP address of a Real-Time target on Mac, Restart.vi throws error -2147220309. Workaround: After setting the IP address, close the System Configuration session, open a new session and then call Restart.vi on the target.
|