ID | Fixed Issue |
---|---|
603477 | Fixed an issue in which the DRAM FIFO Instrument Design Library did not reset properly, and the status information was incorrect. |
372645 | Fixed an issue in which PCI rebalancing occurred in certain hardware combinations or very large systems that included NI PXIe-796XR or NI PXIe-797XR FPGA modules and sometimes caused an operating system crash on boot. |
597192 | Fixed an issue that caused NI MAX and System Configuration API to hang when using an unknown adapter module. |
598087 | Fixed an issue that caused the NI-793xR - MGT Aurora CLIP example to allocate an incorrect instruction address size on the FPGA in LabVIEW 2015. |
594173 | Fixed an issue that caused LabVIEW Real-Time system running the PharLAP OS to hang with 100% CPU usage during a reboot in some cases when using an NI PXIe-796XR FPGA module. |
544097 | Fixed an issue in which the FlexRIO High-Throughput Streaming example did not accurately demonstrate how to stream at the full bandwidth on PXIe-797x FPGA modules. |
Contact NI regarding this document or issues in the document. If you contact NI in regards to a specific issue, reference the ID number given in the document. The ID number contains the current issue ID number as well as the legacy ID number (use the current ID number when contacting NI). You can contact us through any of the normal support channels including phone, email, or the discussion forums. Visit the NI Website to contact us. Also contact us if you find a workaround for an issue that is not listed in the document.