You can contact us by phone, email, or the discussion forums. Visit the NI Website to contact us. If you are contacting NI in regards to a specific issue, be sure to reference the ID. If you have feedback on this document, please contact NI on this NI Developer Zone post.
The following items are known issues in LabVIEW 2014 Robotics Module sorted by Date.
ID | Known Issue | |||||
---|---|---|---|---|---|---|
187772 Return | Performance of AD* VI slows over time If significant changes occur to the map the AD* VI operates on and the VI is configured to mange the epsilon value automatically, the VI runs significantly slower over time. Workaround: Try one of the following:
| |||||
207367 Return | Starter Kit will reboot constantly if LabVIEW 2009 is not installed and no DHCP server is available If the Starter Kit is configured to obtain an IP address via DHCP and there is no DHCP server available then its behaviour is as follows: If LabVIEW 2009 is installed on the sbRIO: the network uses a private IP in 169.254.x.x range If LabVIEW 2009 is not installed on the sbRIO: the network fails to obtain an IP address and reboots Workaround: Setting the IP reset dip switch and rebooting will force the IP address to 0.0.0.0. Allow at least 15 seconds for the network to be initialized before switching the IP reset switch off. Then use the Hardware Setup Wizard or MAX as usual.
| |||||
356420 Return | Robotics Wizard cannot load a manifest file in a folder with a Chinese character in the name Robotics Wizard cannot load a manifest file in a folder with a Chinese character in the name Workaround: Move the manifest file to a new location
| |||||
406186 Return | Error -2147220308 in Hardware Setup Wizard when Connecting to Zynq Target Zynq targets require all web features to be installed to be recognized by the Hardware Setup Wizard. If a Zynq target has been reformatted these features will removed, and error -2147220308 will be thrown in the Hardware Setup Wizard Workaround: In NI MAX install all web features and then restart the target.
| |||||
410068 Return | Hardware Setup Wizard has Slow Target Discovery Time It can take much longer to discover targets in the Hardware Setup Wizard. Workaround: See KB (6B0A80QB): Long Target Search Time in Robotics Hardware Setup for 2013
| |||||
414047 Return | LabVIEW Crash if Project is Closed before Robotics Simulator is Stopped If a VI is still running that uses the Robotics Simulator, and the LabVIEW Project is closed, LabVIEW will crash. Workaround: Avoid closing the project while running the simulation service.
| |||||
394897 Return | NI MAX Does Not Detect Starter Kit 2.0 when Hardware Setup Wizard has Found Target Hardware Setup Wizard locks target when it is discovered in step 3. NI MAX will not be able to discover the locked target if it has not already discovered the target in the past. Workaround: Do not connect to target with NI MAX and Hardware Setup Wizard at the same time.
|
Document last updated on 11/12/2014