Each issue appears as a row in the table and includes the following fields:
|
Composite measurment on a multi-carrier signal with atleast one measurement measuring a single carrier, results in incorrect measurement.
| |||||
|
If you do not have NI-RFSA 14.0 installed, RFMx may prompt you to save some RFmx VIs.
| |||||
456176 |
Vector averaging is converted to RMS averaging in certain cases. Vector averaging is converted to RMS averaging when the acquisition span is greater than the device instantaneous bandwidth. In case of composite measurement, acquisition span is the highest span of all individual measurements.
| |||||
447616 |
Out of memory error occurs when performing spurious emissions measurement when analyzing wide ranges with narrow RBW Out of memory errors may occur when you are analyzing wide ranges with narrow RBW. This is because of the number of samples to be acquired might be huge and requires more processing power to compute spectrum and then perform peak search.
|
Document last updated on 06/23/2014
Contact NI regarding this document or issues in the document. If you contact NI in regards to a specific issue, reference the ID number given in the document. The ID number contains the current issue ID number as well as the legacy ID number (use the current ID number when contacting NI). You can contact us through any of the normal support channels including phone, email, or the discussion forums. Visit the NI Website to contact us. Also contact us if you find a workaround for an issue that is not listed in the document.