ID | Known Issue |
---|
105956
Return | Viewing NI-VISA Options tab on Real-Time controller may hang MAX
On PXI and PC Real-Time controllers with VISA Server installed, MAX occasionally may hang when trying to view the VISA Options tab.
Workaround: N/A
Reported Version: 4.3 | | Resolved Version: N/A | | Added: 08/25/2010 |
|
109538
Return | Slot path shows up incorrectly for multifunction and bridged NI-VISA-based PXI devices
PXI devices that are either behind a PCI bridge or have multiple functions (for example, both Ethernet and SCSI device) show an incorrect slot path in MAX when using a driver generated by the VISA Driver Development Wizard.
Workaround: N/A
Reported Version: 4.3 | | Resolved Version: N/A | | Added: 08/25/2010 |
|
126535
Return | VISA Read STB on Mac OS X waits for NI-VISA-defined timeout even if USB device responds sooner
VISA Read STB always waits for the timeout defined in NI-VISA before returning, even if a USB device returns a response quicker than the timeout value.
Workaround: N/A
Reported Version: 4.4 | | Resolved Version: N/A | | Added: 08/25/2010 |
|
145966
Return | Third-Party USB device communication may timeout after host PC is put into standby
A Windows-based machine communicating with a third-party USB device using a driver not developed by the VISA Driver Development Wizard may timeout if the PC is put into standby mode in the middle of a NI-VISA USB transfer. After the PC is woken up, it thinks the USB device should resend the entire data packet and eventually times out because the packet is not resent.
Workaround: N/A
Reported Version: 4.4 | | Resolved Version: N/A | | Added: 08/25/2010 |
|
164621
Return | NI-VISA does not recognize Bluetooth devices on Windows Mobile
On a Windows Mobile device, Bluetooth devices can act as virtual serial devices, giving them a COM port number. NI-VISA cannot recognize this COM port and gives errors when trying to access it through VISA functions.
Workaround: Use the non-NI-VISA Bluetooth VIs.
Reported Version: 4.4 | | Resolved Version: N/A | | Added: 08/25/2010 |
|
166323
Return | Using interrupts with NI-VISA-based PXI cards on NI RT Hypervisor system may cause hang on reboot
If you are using interrupts with a PXI card that uses an NI-VISA-based driver on an NI RT Hypervisor system, independent reboot of the RT system may hang if the driver does not have the interrupt disarm sequence defined.
Workaround: N/A
Reported Version: 4.5.1 | | Resolved Version: N/A | | Added: 08/25/2010 |
|
182027
Return | Setting serial baud rate with NI-VISA may return errors from third-party serial drivers
NI-VISA may return an error while setting the serial baud rate when using third-party serial drivers, even though setting this same baud rate may work in other third-party applications. This is due to how NI-VISA verifies baud rate settings.
Workaround: N/A
Reported Version: 4.5 | | Resolved Version: 15.0 | | Added: 08/25/2010 |
|
183242
Return | Calling viUsbControlIn on composite USB devices may cause system to blue screen
When using viUsbControlIn or VISA USB Control In.vi, if a composite USB RAW device is passed in as the VISA resource, the system may crash with a blue screen.
Workaround: N/A
Reported Version: 4.6 | | Resolved Version: N/A | | Added: 08/25/2010 |
|
226865
Return | Drivers developed by the VISA Driver Development Wizard on Windows XP Dutch do not install correctly
When using the VISA Driver Development Wizard on Windows XP Dutch, the OS does not correctly recognize the .inf file generated.
Workaround: N/A
Reported Version: 3.4 | | Resolved Version: N/A | | Added: 08/25/2010 |
|
90238
3WP9E800
Return | NI-VISA leaks Mach ports on Mac OS X when communicating with USB Raw devices
When performing a VISA Open and VISA Close on a USB Raw device multiple times inside a loop, the number of Mach ports in Mac OS X increases. This may cause a crash if the code performing these calls is run over an extended period of time.
Workaround: Restart the development/run-time environment
Reported Version: 3.4 | | Resolved Version: N/A | | Added: 08/25/2010 |
|
242354
Return | VISA always adds a parallel port resource
VISA will always add a static resource bound to LPT1 in visaconf.ini. If a system does not have a parallel port, this resource will show up with a yellow exclamation mark in MAX.
Workaround: Delete the parallel port in MAX
Reported Version: 5.0 | | Resolved Version: 15.0 | | Added: 08/09/2011 |
|
255456
Return | Two applications simultaneously calling viLock and viUnlock on the same VISA INSTR resource will eventually result in an error
Two applications that are both trying to lock and unlock a VISA INSTR resource using viLock and viUnlock will result in one of the applications eventually returning error -1073807204: VISA: (Hex 0xBFFF009C) The current session did not have a lock on the resource.
Workaround: N/A
Reported Version: 5.0.1 | | Resolved Version: N/A | | Added: 08/09/2011 |
|
283686
Return | Rebooting a system or refreshing Devices & Interfaces in MAX will remove a key in visaconf.ini
If the following key is added to disable the error replacement character when performing 9-bit VISA serial reads, refreshing Devices & Interfaces in MAX or rebooting the system will remove that key from visaconf.ini: [ASRL-RSRC-ALIAS] DisableErrorReplacement=1
Workaround: N/A
Reported Version: 5.0 | | Resolved Version: N/A | | Added: 08/09/2011 |
|
308006
Return | Providing VISA remote access to a cRIO device may cause duplicate Serial & Parallel entries in MAX
Adding a new permission to the Remote Access List under the VISA Server for a cRIO device may cause duplicate Serial & Parallel entries to appear underneath the device in MAX.
Workaround: N/A
Reported Version: 4.6 | | Resolved Version: N/A | | Added: 08/09/2011 |
|
342419
Return | Block diagram doesn't fully load when using VISA 5.1.x, System Configuration 5.3.x, and LVRT
Workaround: resize or minimize/maximize the block diagram
Reported Version: 5.1 | | Resolved Version: 5.2 | | Added: 08/06/2012 |
|
358525
Return |
NI-VISA LabVIEW support pieces are only visible in the feature tree if the corresponding LabVIEW version is installed on the system
Workaround: N/A
Reported Version: 5.2 | | Resolved Version: N/A | | Added: 08/06/2012 |
|
375426
Return |
Unable to communicate with Agilent GPIB ENet Device
Workaround: N/A
Reported Version: 5.2 | | Resolved Version: N/A | | Added: 10/31/2012 |
|
386369
Return | NI-RIO PXI devices show up twice in NI MAX
Some devices, such as the NI 5645R, show up twice in MAX with different icons and properties.
Workaround: Disable NiViRio.dll VISA passport plugin for NI-RIO, in the passports section of the VISA Options pane. This would not be an obvious option to most users.
Reported Version: 5.3 | | Resolved Version: 5.4 | | Added: 09/6/2013 |
|
393875
Return | Using VISA asynchronous writes along with VISA events in LabVIEW may cause corrupted data to be written to the serial port.
Workaround: Configuring the VISA Write operations to be synchronous or configuring the VISA Wait on Events to be synchronous seems to cause the problem to go away.
Reported Version: 5.3 | | Resolved Version: 5.4 | | Added: 09/6/2013 |
|
404486
Return | Removing and reconnecting a USB device that has interrupt enabled causes a system crash on VxWorks.
Workaround: N/A
Reported Version: 5.3 | | Resolved Version: 5.4 | | Added: 09/6/2013 |
|
409398
Return | GPIB instruments improperly labeled as Not Present in NI Web-base Configuration & Monitoring
GPIB instruments that were previously scanned and found are listed as Not Present.
Workaround: N/A