Each issue appears as a row in the table and includes the following fields:
ID | Known Issue | |||||
---|---|---|---|---|---|---|
276991 | On LabVIEW 2010, the SMT Basic Zoom Power Spectrum (Complex Input) VI slows down indefinitely When using a small dt such as 100 ps, span=1 on LabVIEW 2010, the SMT Basic Zoom Power Spectrum (Complex Input) VI slows down indefinitely. With span=1, execution takes a long time (20 sec) with dt set to 1 uSec. The VI runs faster when dt is set to 100 nSec or 1 nSec. Workaround: N/A
| |||||
294171 | Opening VI in LV projects with Spectral Measurement Toolkit (SMT) dependencies results in Project Dependency Conflict Detected error If you open a VI from a LabVIEW project that has SMT dependencies, the toolkit displays an error about conflicts between different dir.mnu files. Workaround: N/A
| |||||
280673 | Need to relink deprecated VIs/subVIs for which the path has changed If an application built with NI Spectral Measurements Toolkit 2.5.1 or earlier uses deprecated VIs or subVIs from previous versions of the NI Spectral Measurements Toolkit, and you upgrade to NI Spectral Measurements Toolkit 2.6, the application may not find the deprecated VIs/subVIs after you upgrade to NI Spectral Measurements Toolit 2.6, even though the VIs are present on the disk. Workaround: Manually relink the deprecated VIs/subVIs for which the paths have changed.
| |||||
281106 | Upgrading Spectral Measurements Toolkit from a previous installation Upgrading to Spectral Measurements Toolkit 2.5.1 for LabVIEW from a previous version may lead to the installation of the Spectral Measurement Toolkit files to versions of LabVIEW that are not present on the system, in addition to versions of LabVIEW present on the system. This happens only if any of the following standard-specific toolkits are installed on the system:
| |||||
320267 | License Manager unable to check out Spectral Measurements Toolkit license from certain packages in a volume license file If you purchase a bundle, such as ASL or DevSuite that includes the Spectral Measurements Toolkit, the license of Spectral Measurements Toolkit is not present in the list of licenses for that bundle. Hence, you will be unable to use the licensed version of Spectral Measurements Toolkit. Workaround: Use a local license for Spectral Measurements Toolkit.
|
Contact NI regarding this document or issues in the document. If you contact NI in regards to a specific issue, reference the ID number given in the document. The ID number contains the current issue ID number as well as the legacy ID number (use the current ID number when contacting NI). You can contact us through any of the normal support channels including phone, email, or the discussion forums. Visit the NI Website to contact us. Also contact us if you find a workaround for an issue that is not listed in the document.