National Instruments is committed to maintaining compatibility with Microsoft Windows technology changes. However, NI has become aware of a number of issues of potential significance regarding Microsoft Windows 7. To learn how Windows 7 affects your use of NI products, visit ni.com/info and enter the Info Code windows7
.
The following items are known issues in LabVIEW 2012 Statechart Module sorted by Date.
ID | Known Issue | |||||
---|---|---|---|---|---|---|
100185 Return | Replacing a block diagram constant when configuring a statechart state node or transition node may not delete the original block diagram constant Replacing a block diagram constant with the "Select a VI..." option in the statechart state node or transition node configuration dialog may not delete original block diagram constant Workaround: Delete the original block diagram constant manually.
| |||||
110487 Return | Deleting cluster constant in statechart configuration guard/action diagram can crash LabVIEW In the Guard or Action diagram of the Configure State dialog box, if you try to delete the contents of a block diagram cluster that is typedef'ed, and then delete the cluster constant itself, LabVIEW might crash. Workaround: When deleting a cluster constant in the Configure State dialog box, delete the entire constant at once instead of deleting the contents first.
| |||||
118558 Return | Issue with copying/pasting states/transitions between different statecharts of the same name in different application instances Copying and pasting a statechart diagram from a statechart state or transition in one application instance to a different statechart of the same name in another application instance generates an error. Workaround: Ensure the statecharts between which you want to copy and paste states/transitions have different names.
| |||||
197572 Return | The 12th element in the Inputs.ctl Cluster of a Statechart is always disabled When creating an Inputs.ctl for a statechart, the 12th element cannot be selected when configuring the transition from the Diagram.vi. Workaround: N/A
| |||||
222978 Return | Clean up diagram creates loose wires In some cases, clean up diagram can create loose wires which causes the VI to become broken. Workaround: N/A
| |||||
159669 Return | Undo does not always work correctly with statecharts In certain circumstances undo will not be available with statecharts after an action that should be able to be undone. Workaround: N/A
| |||||
91918 Return | Revert is not available on LabVIEW Statechart files Revert is not available on LabVIEW Statechart files Workaround: If you want to discard changes you have made to a statechart, close the statechart and all callers and do not save the changes, then reopen the statechart.
|