Using SLSC with the Inverter Test System
- Updated2023-02-20
- 2 minute(s) read
Using SLSC with the Inverter Test System
Refer to the following topics to learn about using SLSC boards in your Inverter Test System.
SLSC Connections
SLSC | Description | Slot | Mass Interconnect PCB | Fault Insertion |
---|---|---|---|---|
OP8935-F | 8 input, 8 output SLSC conditioning board that supports signal conditioning of all analog signals to DUT 1 and DUT 2 with scaling and fault insertion on every channel | 1 | DUT 1 and DUT 2 | Yes |
OP8913-F | 16 high-speed digital input, 16 high-speed digital output digital SLSC conditioning board with fault insertion on every channel | 2 | DUT 1 and DUT 2 | Yes |
OP8911-F | 32 high-speed digital output SLSC conditioning board[1] | 3 | DUT 1 and DUT 2 | Yes |
DUT 3 and DUT 4 | ||||
OP8934-F | 16 analog output differential from single-ended input analog SLSC conditioning board with fault insertion | 4 | DUT 1 and DUT 2 | Yes |
OP8940-F | Channel passthrough board that does not affect signals with fault insertion | 5 | Vehicle Control Module | Yes |
DUT 1 and DUT 2 | ||||
DUT 3 and DUT 4 | ||||
SLSC-12201 | 32-channel configurable digital input/output board | 6 | Vehicle Control Module | No |
DUT 1 and DUT 2 | ||||
DUT 3 and DUT 4 | ||||
OP8940-F | Channel passthrough board that does not affect signals with fault insertion | 7 | Vehicle Control Module | Yes |
DUT 1 and DUT 2 | ||||
DUT 3 and DUT 4 | ||||
OP8940-F | Channel passthrough board that does not affect signals with fault insertion | 8 | Vehicle Control Module | Yes |
SET-1210 | 16-channel resistor simulator SLSC board | 9 | Vehicle Control Module | No |
DUT 1 and DUT 2 | ||||
DUT 3 and DUT 4 | ||||
OP8935-F | 8 input, 8 output SLSC conditioning board that supports signal conditioning of all analog signals to DUT 1 and DUT 2 with scaling and fault insertion on every channel | 10 | DUT 3 and DUT 4 | Yes |
OP8913-F | 16 high-speed digital input, 16 high-speed digital output digital SLSC conditioning board with fault insertion on every channel | 11 | DUT 3 and DUT 4 | Yes |
OP8934-F | 16 analog output differential from single-ended input analog SLSC conditioning board with fault insertion | 12 | DUT 3 and DUT 4 | Yes |
Fault Insertion
Every analog and digital channel is equipped with a fault insertion unit that you can use to simulate hardware failure modes and integrate those failure modes into your automated tests.
1 The integrator can change the output configuration of this instrument.