SWB-2814 Overview
- Updated2023-02-20
- 5 minute(s) read
SWB-2814 Overview
SWB-2814 Pinout
Type A
Signal | Description |
---|---|
ABxW0 | Wire 0 analog bus row connection |
ABxW1 | Wire 1 analog bus row connection |
CxW0 | Wire 0 column connection |
CxW1 | Wire 1 column connection |
GND | Safety interlock ground connection |
INTRLK | Safety interlock resistor connection |
— | No connection |
Type B
Signal | Description |
---|---|
CxW0 | Wire 0 column connection |
CxW1 | Wire 1 column connection |
GND | Safety interlock ground connection |
INTRLK | Safety interlock resistor connection |
— | No connection |
SWB-2814 Topology
Multiple modules of the same type can be combined. The following table lists possible topologies.
Number of Modules | Topology |
---|---|
1 | 2-Wire 8×9 Matrix |
2 | 2-Wire 8×18 Matrix |
3 | 2-Wire 8×27 Matrix |
4 | 2-Wire 8×36 Matrix |
5 | 2-Wire 8×45 Matrix |
6 | 2-Wire 8×54 Matrix |
2-Wire 8×9 Matrix
Module software name: Configured Topology (NISWITCH_TOPOLOGY_CONFIGURED_TOPOLOGY)
Hardware Diagram
Making a Connection
The immediate operation, the niSwitch Connect Channels VI or the niSwitch_Connect function with parameters card1r2 and c1 result in the following connection:
- signal connected to CARD1R2W0 is routed to C1W0
- signal connected to CARD1R2W1 is routed to C1W1
Relay Names
Refer to the following list for relay names of one module.
- kCARD1AB0W0...kCARD1AB7W0
- kCARD1AB0W1...kCARD1AB7W1
- kCARD1R0C0W0...kCARD1R0C8W0
- kCARD1R0C0W1...kCARD1R0C8W1
- kCARD1R1C0W0...kCARD1R1C8W0
- kCARD1R1C0W1...kCARD1R1C8W1
- kCARD1R2C0W0...kCARD1R2C8W0
- kCARD1R2C0W1...kCARD1R2C8W1
- kCARD1R3C0W0...kCARD1R3C8W0
- kCARD1R3C0W1...kCARD1R3C8W1
- kCARD1R4C0W0...kCARD1R4C8W0
- kCARD1R4C0W1...kCARD1R4C8W1
- kCARD1R5C0W0...kCARD1R5C8W0
- kCARD1R5C0W1...kCARD1R5C8W1
- kCARD1R6C0W0...kCARD1R6C8W0
- kCARD1R6C0W1...kCARD1R6C8W1
- kCARD1R7C0W0...kCARD1R7C8W0
- kCARD1R7C0W1...kCARD1R7C8W1
SWB-2814 Relay Replacement
The module uses reed relays.
Relay | Relay Manufacturer | Part Number |
---|---|---|
Matrix | Meder | MS05-BV50980 |
Safety (Reference Designators K15, K16, K45, K46, K74, K75, K104, and K105) | Tyco Electronics | 5-1462039-8 |
Relay Kit | Part Number |
---|---|
National Instruments (10 matrix relays) | 781450-10 |
National Instruments (10 safety relays) | 781089-10 |
Complete the following sets of steps to locate and replace a failed relay.
Locate the Relay
- Ground yourself using a grounding strap or a ground connected to your PXI
chassis. Note Properly grounding yourself prevents damage to your module from electrostatic discharge.
- Locate the relay you want to replace. Refer to the following figure and table
for relay locations.
The relay names in the following table correspond to a single-card device.
Relay Name | Reference Designator | Relay Name | Reference Designator | Relay Name | Reference Designator | Relay Name | Reference Designator |
---|---|---|---|---|---|---|---|
kcard1ab0w0 | K7 | kcard1r1c3w0 | K34 | kcard1r3c5w0 | K81 | kcard1r5c7w0 | K110 |
kcard1ab0w1 | K14 | kcard1r1c3w1 | K41 | kcard1r3c5w1 | K88 | kcard1r5c7w1 | K117 |
kcard1ab1w0 | K23 | kcard1r1c4w0 | K35 | kcard1r3c6w0 | K66 | kcard1r5c8w0 | K109 |
kcard1ab1w1 | K30 | kcard1r1c4w1 | K42 | kcard1r3c6w1 | K72 | kcard1r5c8w1 | K116 |
kcard1ab2w0 | K37 | kcard1r1c5w0 | K36 | kcard1r3c7w0 | K65 | kcard1r6c0w0 | K134 |
kcard1ab2w1 | K44 | kcard1r1c5w1 | K43 | kcard1r3c7w1 | K71 | kcard1r6c0w1 | K141 |
kcard1ab3w0 | K53 | kcard1r1c6w0 | K22 | kcard1r3c8w0 | K64 | kcard1r6c1w0 | K135 |
kcard1ab3w1 | K60 | kcard1r1c6w1 | K29 | kcard1r3c8w1 | K70 | kcard1r6c1w1 | K142 |
kcard1ab4w0 | K73 | kcard1r1c7w0 | K21 | kcard1r4c0w0 | K90 | kcard1r6c2w0 | K136 |
kcard1ab4w1 | K82 | kcard1r1c7w1 | K28 | kcard1r4c0w1 | K97 | kcard1r6c2w1 | K143 |
kcard1ab5w0 | K89 | kcard1r1c8w0 | K20 | kcard1r4c1w0 | K91 | kcard1r6c3w0 | K137 |
kcard1ab5w1 | K96 | kcard1r1c8w1 | K27 | kcard1r4c1w1 | K98 | kcard1r6c3w1 | K144 |
kcard1ab6w0 | K103 | kcard1r2c0w0 | K47 | kcard1r4c2w0 | K92 | kcard1r6c4w0 | K138 |
kcard1ab6w1 | K112 | kcard1r2c0w1 | K54 | kcard1r4c2w1 | K99 | kcard1r6c4w1 | K145 |
kcard1ab7w0 | K119 | kcard1r2c1w0 | K48 | kcard1r4c3w0 | K93 | kcard1r6c5w0 | K139 |
kcard1ab7w1 | K126 | kcard1r2c1w1 | K55 | kcard1r4c3w1 | K100 | kcard1r6c5w1 | K146 |
kcard1r0c0w0 | K1 | kcard1r2c2w0 | K49 | kcard1r4c4w0 | K94 | kcard1r6c6w0 | K148 |
kcard1r0c0w1 | K8 | kcard1r2c2w1 | K56 | kcard1r4c4w1 | K101 | kcard1r6c6w1 | K155 |
kcard1r0c1w0 | K2 | kcard1r2c3w0 | K50 | kcard1r4c5w0 | K95 | kcard1r6c7w0 | K149 |
kcard1r0c1w1 | K9 | kcard1r2c3w1 | K57 | kcard1r4c5w1 | K102 | kcard1r6c7w1 | K156 |
kcard1r0c2w0 | K3 | kcard1r2c4w0 | K51 | kcard1r4c6w0 | K106 | kcard1r6c8w0 | K150 |
kcard1r0c2w1 | K10 | kcard1r2c4w1 | K58 | kcard1r4c6w1 | K113 | kcard1r6c8w1 | K157 |
kcard1r0c3w0 | K4 | kcard1r2c5w0 | K52 | kcard1r4c7w0 | K107 | kcard1r7c0w0 | K162 |
kcard1r0c3w1 | K11 | kcard1r2c5w1 | K59 | kcard1r4c7w1 | K114 | kcard1r7c0w1 | K163 |
kcard1r0c4w0 | K5 | kcard1r2c6w0 | K61 | kcard1r4c8w0 | K108 | kcard1r7c1w0 | K164 |
kcard1r0c4w1 | K12 | kcard1r2c6w1 | K67 | kcard1r4c8w1 | K115 | kcard1r7c1w1 | K165 |
kcard1r0c5w0 | K6 | kcard1r2c7w0 | K62 | kcard1r5c0w0 | K120 | kcard1r7c2w0 | K166 |
kcard1r0c5w1 | K13 | kcard1r2c7w1 | K68 | kcard1r5c0w1 | K127 | kcard1r7c2w1 | K167 |
kcard1r0c6w0 | K17 | kcard1r2c8w0 | K63 | kcard1r5c1w0 | K121 | kcard1r7c3w0 | K161 |
kcard1r0c6w1 | K24 | kcard1r2c8w1 | K69 | kcard1r5c1w1 | K128 | kcard1r7c3w1 | K168 |
kcard1r0c7w0 | K18 | kcard1r3c0w0 | K76 | kcard1r5c2w0 | K122 | kcard1r7c4w0 | K147 |
kcard1r0c7w1 | K25 | kcard1r3c0w1 | K83 | kcard1r5c2w1 | K129 | kcard1r7c4w1 | K154 |
kcard1r0c8w0 | K19 | kcard1r3c1w0 | K77 | kcard1r5c3w0 | K123 | kcard1r7c5w0 | K133 |
kcard1r0c8w1 | K26 | kcard1r3c1w1 | K84 | kcard1r5c3w1 | K130 | kcard1r7c5w1 | K140 |
kcard1r1c0w0 | K31 | kcard1r3c2w0 | K78 | kcard1r5c4w0 | K124 | kcard1r7c6w0 | K153 |
kcard1r1c0w1 | K38 | kcard1r3c2w1 | K85 | kcard1r5c4w1 | K131 | kcard1r7c6w1 | K160 |
kcard1r1c1w0 | K32 | kcard1r3c3w0 | K79 | kcard1r5c5w0 | K125 | kcard1r7c7w0 | K152 |
kcard1r1c1w1 | K39 | kcard1r3c3w1 | K86 | kcard1r5c5w1 | K132 | kcard1r7c7w1 | K159 |
kcard1r1c2w0 | K33 | kcard1r3c4w0 | K80 | kcard1r5c6w0 | K111 | kcard1r7c8w0 | K151 |
kcard1r1c2w1 | K40 | kcard1r3c4w1 | K87 | kcard1r5c6w1 | K118 | kcard1r7c8w1 | K158 |
Replace the Relay
The module uses lead-free assemblies.
Make sure that you have the following items:
- Temperature-regulated soldering iron set to 371 °C (700 °F) for lead-free solder rework
- 96.5/3.0/0.5 Tin/Silver/Copper solder (flux core) for lead-free solder rework
- Solder wick
- Fine pick
- Isopropyl alcohol
- Cotton swabs
Replace the relay as you would any other through-hole part. Trim the replaced relay leads to no more than 0.5 mm (0.02 inch) from the PCB.