PXIe-1082DC Specifications
- Updated2023-02-19
- 7 minute(s) read
PXIe-1082DC Specifications
This document contains specifications for the PXIe-1082DC chassis.
Electrical
The following section provides information about the PXIe-1082DC AC input and DC output.
DC Input
Input voltage range | 11 to 32 VDC | ||||||||
Input current rating | 45 to 15 A | ||||||||
Over-current protection | 50 A circuit breaker | ||||||||
| |||||||||
Efficiency | 65% typical | ||||||||
Power disconnect | The DC power cable provides main power disconnect. Do not position the equipment so that it is difficult to disconnect the power cord. The front panel power switch causes the internal chassis power supply to provide DC power to the CompactPCI/PXI Express backplane. You also can use the rear-panel D-SUB 9-pin connector and power mode switch to control the internal chassis power supply. |
DC Output
Voltage | Maximum Current |
---|---|
+3.3 V | 32 A |
+5 V | 19 A |
+12 V | 32 A |
-12 V | 1.5 A |
5 VAUX | 2.0 A |
Slot | +5 V | V (I/O) | +3.3 V | +12 V | -12 V | 5 VAUX |
---|---|---|---|---|---|---|
System Controller Slot | 15 A | - | 15 A | 30 A | - | 1 A |
System Timing Slot | - | - | 6 A | 4 A | - | 1 A |
Hybrid Peripheral Slot with PXI-1 Peripheral | 6 A | 5 A | 6 A | 1 A | 1 A | - |
Hybrid Peripheral Slot with PXI-5 Peripheral | - | - | 6 A | 4 A | - | 1 A |
The maximum power dissipated in a peripheral slot should not exceed 38.25 W.
Voltage | Load Regulation |
---|---|
+3.3 V | <5% |
+12 V | <5% |
+5 V | <5% |
-12 V | <5% |
Voltage | Maximum Ripple and Noise |
---|---|
+3.3 V | 50 mVpp |
+12 V | 120 mVpp |
+5 V | 50 mVpp |
-12 V | 50 mVpp |
Over-current protection | All outputs protected from short circuit and overload (some faults require a power cycle for recovery) | ||||
| |||||
Power supply shuttle MTTR | Replacement in under 5 minutes |
Chassis Cooling
Module cooling system | Forced air circulation (positive pressurization) through two 110 cfm fans with High/Auto speed selector |
Slot airflow direction | Bottom of module to top of module |
Module cooling intake | Bottom rear of chassis |
Module cooling exhaust | Along both sides and top of chassis |
Power supply cooling system | Forced air circulation through integrated fan |
Power supply cooling intake | Right side of chassis |
Power supply cooling exhaust | Left side of chassis |
Environmental
Maximum altitude | 4,600 m (570 mbar) (at 25 °C ambient) |
Measurement Category | I |
Pollution Degree | 2 |
Indoor use only.
Operating Environment
Ambient temperature range | 0 °C to 55 °C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2. Meets MIL-PRF-28800F Class 3 low temperature limit and MIL-PRF-28800F Class 2 high temperature limit.) |
Relative humidity range | 10% to 90%, noncondensing (Tested in accordance with IEC-60068-2-56.) |
Storage Environment
Ambient temperature range | –40 °C to 71 °C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2. Meets MIL-PRF-28800F Class 3 limits.) |
Relative humidity range | 5% to 95%, noncondensing (Tested in accordance with IEC-60068-2-56.) |
Shock and Vibration
Operational shock | 30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC-60068-2-27. Meets MIL-PRF-28800F Class 2 limits.) |
Random Vibration Operating | 5 to 500 Hz, 0.3 grms |
Nonoperating | 5 to 500 Hz, 2.4 grms (Tested in accordance with IEC-60068-2-64. Nonoperating test profile exceeds the requirements of MIL-PRF-28800F, Class 3.) |
Sound Pressure Level (at Operator Position)
(Tested in accordance with ISO 7779. Meets MIL-PRF-28800F requirements.)
Auto fan (up to ~30 °C ambient) | 48.7 dBA |
High fan | 61.6 dBA |
Sound Power
Auto fan (up to ~30 °C ambient) | 57.7 dBA |
High fan | 72.5 dBA |
Safety Compliance Standards
This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:
- IEC 61010-1, EN 61010-1
- UL 61010-1, CSA C22.2 No. 61010-1
Electromagnetic Compatibility
This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:
- EN 61326 (IEC 61326): Class A emissions; Basic immunity
- EN 55011 (CISPR 11): Group 1, Class A emissions
- AS/NZS CISPR 11: Group 1, Class A emissions
- FCC 47 CFR Part 15B: Class A emissions
- ICES-001: Class A emissions
CE Compliance

This product meets the essential requirements of applicable European Directives, as follows:
- 2014/35/EU; Low-Voltage Directive (safety)
- 2014/30/EU; Electromagnetic Compatibility Directive (EMC)
- 2011/65/EU; Restriction of Hazardous Substances (RoHS)
- 2014/53/EU; Radio Equipment Directive (RED)
- 2014/34/EU; Potentially Explosive Atmospheres (ATEX)
Product Certifications and Declarations
Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link.
Environmental Management
NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.
For additional environmental information, refer to the Engineering a Healthy Planet web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document.
EU and UK Customers
Backplane
Size | 3U-sized; one system slot (with three system expansion slots) and 7 peripheral slots. Compliant with IEEE 1101.10 mechanical packaging. PXI Express Specification compliant. Accepts both PXI Express and CompactPCI (PICMG 2.0 R 3.0) 3U modules. |
Backplane bare-board material | UL 94 V-0 Recognized |
Backplane connectors | Conforms to IEC 917 and IEC 1076-4-101, UL 94 V-0 rated |
System Synchronization Clocks (PXI_CLK10, PXIe_CLK100, PXIe_SYNC100)
10 MHz System Reference Clock: PXI_CLK10
Maximum slot-to-slot skew | 500 ps |
Accuracy | ±25 ppm max (guaranteed over the operating temperature range) |
Maximum jitter | 5 ps RMS phase-jitter (10 Hz–1 MHz range) |
Duty-factor | 45% to 55% |
Unloaded signal swing | 3.3 V ±0.3 V |
100 MHz System Reference Clock: PXIe_CLK100 and PXIe_SYNC100
Maximum slot-to-slot skew | 100 ps |
Accuracy | ±25 ppm max (guaranteed over the operating temperature range) |
Maximum jitter | 3 ps RMS phase-jitter (10 Hz to 12 kHz range), 2 ps RMS phase-jitter (12 kHz to 20 MHz range) |
Duty-factor for PXIe_CLK100 | 45% to 55% |
Absolute differential voltage (When terminated with a 50 Ω load to 1.30 V or Thévenin equivalent) | 400 to 1000 mV |
External 10 MHz Reference Out
(BNC on rear panel of chassis)
Accuracy | ±25 ppm max (guaranteed over the operating temperature range) |
Maximum jitter | 5 ps RMS phase-jitter (10 Hz to 1 MHz range) |
Output amplitude | 1 VPP ±20% square-wave into 50 Ω, 2 VPP unloaded |
Output impedance | 50 Ω ±5 Ω |
External Clock Source
Frequency | 10 MHz ±100 ppm | ||||||
| |||||||
Rear panel BNC input impedance | 50 Ω ±5 Ω | ||||||
Maximum jitter introduced by backplane | 1 ps RMS phase-jitter (10 Hz to 1 MHz range) |
PXIe_SYNC_CTRL
VIH | 2.0 to 5.5 V |
VIL | 0 to 0.8 V |
PXI Star Trigger
Maximum slot-to-slot skew | 250 ps |
Backplane characteristic impedance | 65 Ω ±10% |
For other specifications, refer to the PXI-1 Hardware Specification.
PXI Differential Star Triggers
(PXIe-DSTARA, PXIe-DSTARB, PXIe-DSTARC)
Maximum slot-to-slot skew | 150 ps |
Maximum differential skew | 25 ps |
Backplane differential impedance | 100 Ω ±10% |
For other specifications, the PXIe-1082DC complies with the PXI-5 PXI Express Hardware Specification.
Mechanical
|
Weight | 19.4 lb (8.8 kg) |
Chassis materials | Sheet Aluminum (5052-H32, 3003-H14, and 6061-T6), Extruded Aluminum (6060-T6), and Cold Rolled Steel, PC-ABS, Santoprene, Nylon |
Finish | Conductive Clear Iridite on Aluminum, Clear Chromate Zinc Plating on Cold Rolled Steel, Polyurethane Enamel |
The following figures show the PXIe-1082DC chassis dimensions. The holes shown are for the installation of the optional rack mount kits. You can install those kits on the front or rear of the chassis, depending on which end of the chassis you want to face toward the front of the instrument cabinet. Notice that the front and rear chassis mounting holes (size M4) are symmetrical.
- Front Rack Mount Kit
- PXIe-1082DC Chassis
- Rear Rack Mount Kit