2-Wire 8x16 Matrix

Module software name: 2529/2-Wire 8x16 Matrix (NISWITCH_TOPOLOGY_2529_2_WIRE_8X16_MATRIX)

Hardware Diagram


1378

Making a Connection

In this topology, you can connect any row to any column. When connecting signals to r1, you would connect them to R1+ and R1– in the terminal block. When connecting signals to c0, you would connect them to C0+ and C0– in the terminal block.

Connect the channels using the niSwitch Connect Channels VI or the niSwitch_Connect. For example, to connect row 1 to column 1, call the niSwitch Connect Channels VI or the niSwitch_Connect function with the channel 1 parameter set to r1 and the channel 2 parameter set to c1.

When scanning the module in 8×16 matrix topology, a typical scan list entry could be r5->c1;. This entry routes the signal connected to row 5 to column 1.

Terminal Block Connections


1378

The following table lists the module pins that the NI TB-2635 terminal block shorts and the column connections created. If you do not use the NI TB-2635 terminal block, short the pins externally to achieve a 2-wire 8×16 matrix topology. Refer to the module pinout for pin locations.

Connection Pins Connection Pins Connection Pins Connection Pins
C0+ B24, B14 C4+ C24,C14 C8+ B19,B9 C12+ C19,C9
C0- A24,A14 C4- D24,D14 C8- A19,A9 C12- D19,D9
C1+ B23,B13 C5+ C23,C13 C9+ B18,B8 C13+ C18,C8
C1- A23,A13 C5- D23,D13 C9- A18,A8 C13- D18,D8
C2+ B22,B12 C6+ C22,C12 C10+ B17,B7 C14+ C17,C7
C2- A22,A12 C6- D22,D12 C10- A17,A7 C14- D17,D7
C3+ B21,B11 C7+ C21,C11 C11+ B16,B6 C15+ C16,C6
C3- A21,A11 C7- D21,D11 C11- A16,A6 C15- D16,D6

The following table lists the module pins and their associated row connection.

Connection Pins Connection Pins Connection Pins Connection Pins
R0+ B25 R2+ B20 R4+ B15 R6+ B10
R0- A25 R2- A20 R4- A15 R6- A10
R1+ C25 R3+ C20 R5+ C15 R7+ C10
R1- D25 R3- D20 R5- D15 R7- D10