Fetch S-parameters (Complex) VI

Fetches the frequency and the complex number of a single S-parameter measurement.


icon

Inputs/Outputs

  • cdatavalref.png S-Par Reference In

    Specifies the session reference handle of the S-parameter measurement session.

  • cenum.png S-Parameter Selection

    Specifies which S-parameter measurement the VI fetches. The default value is S11.

  • cerrcodeclst.png error in

    Error conditions that occur before this node runs. This input provides standard error in functionality.

  • idatavalref.png S-Par Reference Out

    Returns the session reference handle of the S-parameter measurement session.

  • i1dcdb.png S-Parameters

    Returns a single S-parameter measurement. This value is expressed as a complex number.

  • i1ddbl.png Frequency (Hz)

    Returns the frequency of the specified S-parameter. This value is expressed in Hz.

  • ierrcodeclst.png error out

    Error information. This output provides standard error out functionality.