RfsgWarning Properties
- Updated2024-05-08
- 6 minute(s) read
RfsgWarning Properties
The RfsgWarning type exposes the following members.
Properties
Name | Description | |
---|---|---|
![]() ![]() | ArbOverflowDigitalGainWarningCode |
Gets the warning code when overflow is detected in the Arb's digital gain circuit.
|
![]() ![]() | AwgWarningCode |
Gets the warning code from AWG.
|
![]() ![]() | BandwidthExceededWarningCode |
Gets the warning code when signal bandwidth exceeds FIR filter passband bandwidth.
|
![]() ![]() | CicFilterOverflowWarningCode |
Gets the warning code when overflow is detected in the Arb's CIC filter and output waveform was clipped.
|
![]() | Code |
Gets the error code that is assigned to the warning.
|
![]() ![]() | CoercedIQRateNotReadWarningCode |
Gets the warning code when the IQ rate was coerced, but coerced IQ rate is not read.
|
![]() ![]() | CompensationLimitedWarningCode |
Gets the warning code when the thermal correction has reached its limit.
|
![]() ![]() | FirFilterOverflowWarningCode |
Gets the warning code when overflow is detected in the Arb's FIR Filter.
|
![]() ![]() | InaccurateTemperatureWarningCode |
Gets the warning code when more variation in the readings is found than expected while averaging temperature sensor readings.
|
![]() ![]() | IncompatibleFileVersionWarningCode |
Gets the warning code when the file version is not fully compatible with this driver.
|
![]() ![]() | InternalWarningCode |
Gets the warning code for an internal warning.
|
![]() ![]() | InvalidAttenuatorWarningCode |
Gets the warning code when attenuator hold is enabled, but the held attenuator combination is not calibrated at the new frequency.
|
![]() ![]() | InvalidAttributeNameWarningCode |
Gets the warning code when the attribute name in the file was not recognized or is not supported.
|
![]() ![]() | InvalidCalibrationConstantsWarningCode |
Gets the warning code when Calibration constants are invalid.
|
![]() ![]() | InvalidWaveformFilepathWarningCode |
Gets the warning code when the waveform filepath is invalid.
|
![]() ![]() | IQSumOverflowWarningCode |
Gets the warning code when the Arb's OSP circuit detected an overflow due to an IQ pair with an absolute value greater than 1.0. |
![]() ![]() | LOWarningCode |
Gets the warning code from LO.
|
![]() | Message |
Gets or sets the message that describes the warning.
|
![]() ![]() | NotPhaseContinuousWarningCode |
Gets the warning code when output signal is not be phase continuous.
|
![]() ![]() | OutOfRangeWarningCode |
Gets the warning code when the specified value is outside the valid range and device performance is not guaranteed.
|
![]() ![]() | OutOfSpecificationUserSettingWarningCode |
Gets the warning code when the requested property value exceeds device specification limits.
|
![]() ![]() | PowerLevelInaccuracyWarningCode |
Gets the warning code when unable to correct for temperature deviation.
|
![]() ![]() | PowerOutOfRangeWarningCode |
Gets the warning code when attenuator hold is enabled, and the requested power level is out of range for the selected attenuator.
|
![]() ![]() | ReadAndDownloadUnsuccessfulWarningCode |
Gets the warning code when reading the waveforms from a TDMS file is unsuccessful.
|
![]() ![]() | ReversePowerProtectionWarningCode |
Gets the warning code when the specified value is outside the valid range.
|
![]() ![]() | SignalOutsidePassbandWarningCode |
Gets the warning code when the signal is outside of the upconverter passband.
|
![]() ![]() | UnexpectedDriverWarningCode |
Gets the warning code for an unexpected driver warning.
|
![]() ![]() | UpconverterWarningCode |
Gets the warning code from Upconverter.
|