Counter Input:Count Edges:Input:Hysteresis Property
- Updated2023-02-21
- 1 minute(s) read
Counter Input:Count Edges:Input:Hysteresis Property
Short Name: CI.CountEdges.Hyst
Property of DAQmx Channel
Specifies a hysteresis level to apply to CI.CountEdges.ThreshVoltage. When CI.CountEdges.ActiveEdge is rising, the source signal must first fall below CI.CountEdges.ThreshVoltage minus the hysteresis before a rising edge is detected at CI.CountEdges.ThreshVoltage. When CI.CountEdges.ActiveEdge is falling, the source signal must first rise above CI.CountEdges.ThreshVoltage plus the hysteresis before a falling edge is detected at CI.CountEdges.ThreshVoltage.
Remarks
The following table lists the characteristics of this property.
Permissions | read/write |
Resettable | yes |
Settable while task is running | device-specific |
Available in Run-Time Engine | yes |