Counter Output:General Properties:More:Advanced:Data Transfer and Memory:Use Only Onboard Memory Property
- Updated2023-02-21
- 1 minute(s) read
Counter Output:General Properties:More:Advanced:Data Transfer and Memory:Use Only Onboard Memory Property
Short Name: CO.UseOnlyOnBrdMem
Property of DAQmx Channel
Specifies whether to write samples directly to the onboard memory of the device, bypassing the memory buffer. Generally, you cannot update onboard memory directly after you start the task. Onboard memory includes data FIFOs.
Remarks
The following table lists the characteristics of this property.
Permissions | read/write |
Resettable | yes |
Settable while task is running | device-specific |
Available in Run-Time Engine | yes |