DWDT Copy Waveform dt VI

Replaces all dt values with the dt value of the waveform at index position in waveforms in. The data type you wire to the waveforms in input and the data type of the Y component of the analog waveform determine the polymorphic instance to use.


icon

Inputs/Outputs

  • c1ddigwdt.png waveforms in

    waveforms in contains the digital waveforms for which the time increment values are replaced by the time increment of the digital waveform indicated by index. The default is empty.

  • ci32.png index

    index is the specifier that the waveform in the waveforms in array uses for the dt value. The default is 0.

  • cerrcodeclst.png error in (no error)

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

  • i1ddigwdt.png waveforms out

    waveforms out contains digital waveforms for which the dt values are all identical.

  • ierrcodeclst.png error out

    error out contains error information. This output provides standard error out functionality.