ITS-16250 Getting Started

Verifying the System Requirements

To use the ITS-16250 , your system must meet certain requirements. The ITS-16250 is designed to work with Hirose type B ix Industrial and VPC iCon connectors. For more information about compatible cables and contacts, refer to the VPC documentation.

Unpacking the Kit

Notice To prevent electrostatic discharge (ESD) from damaging the device, ground yourself using a grounding strap or by holding a grounded object, such as your computer chassis.
  1. Touch the antistatic package to a metal part of the computer chassis.
  2. Remove the device from the package and inspect the device for loose components or any other sign of damage.
    Notice Never touch the exposed pins of connectors.
    Note Do not install a device if it appears damaged in any way.
  3. Unpack any other items and documentation from the kit.
Store the device in the antistatic package when the device is not in use.

Verifying the Kit Contents

  • ITS-16250 Mass Interconnect PCB Assembly
  • VPC iCon receiver frame (NI part number 755315-01)
  • VPC iCon receiver protective cover
  • Four 4-40 x 3/16 in. panhead screws (NI part number 740914-01)
  • Two 4-40 x 1/2 in. truss head screws (NI part number 741703-01)
  • ITS-16250 Getting Started Guide

Other Equipment

There are several required items not included in your kit that you need to operate the ITS-16250 . Your application may require additional items not included in your kit to install or operate your ITS-16250 .

Required Items

  • #1 Phillips screwdriver
  • VPC iCon documentation

Optional Items

  • Four 1/2 in. 4-40 standoffs

Installing the ITS-16250

Complete the following steps to install the ITS-16250 to the system panel.

  1. Secure the iCon receiver frame to the panel using the 2-56 screws and nuts as shown in the following image. Skip this step if the frame is preinstalled in your system.
    Figure 1. Installing the iCon Receiver Frame to the System Panel

    1378

  2. Secure the ITS-16250 to the frame using the 4-40 truss head screws. Figure 2 indicates the holes for each screw type.
  3. Engage the captive 2-56 screws in the iCon connectors through the tool access holes.
  4. Secure the ITS-16250 to the panel using the 4-40 x 3/16 in. panhead screws.
    1. (Optional) If you are using a custom panel, use 1/2 in. 4-40 standoffs as needed (not included).
    Figure 2. ITS-16250 Screw Holes

    1378

    1. 4-40 x 3/16 in. panhead screw holes
    2. Captive 2-56 screw tool access holes
    3. 4-40 truss head screw holes
(Optional) Refer to the Receiver Protective Cover Installation instructions in the VPC iCon User Manual to install a cover.