Product Descriptions
- Updated2022-05-02
- 12 minute(s) read
Product Descriptions
NI-9210: 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module
NI-9211: 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module
NI-9212: 8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module
NI-9213: 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
NI-9214: 16-Channel, 68 S/s Aggregate, ±78 mV, Isothermal C Series Temperature Input Module
NI-9216: 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
NI-9217: 4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
NI-9226: 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
Physical Characteristics
| |||||||||||||||||||||||||||||||||||||
Dimensions | Visit ni.com/dimensions and search by module number. |
NI-9210 with Spring Terminal
| |||||||||||
| |||||||||||
|
NI-9210 with Mini-TC
| |||||||||||||||||||||||
|
NI-9211 with Screw Terminal
| |||||||||||||
|
NI-9212 (TB-9212 with Screw Terminal),
NI-9214 (TB-9214)
| |||||||||||||||||||
|
NI-9212 (TB-9212 with Mini-TC)
|
NI-9213 with Push-In Spring Terminal,
NI-9216 with Push-In Spring Terminal, NI-9226 with Push-In Spring Terminal (Black/Orange
Connector)
| |||||||||||||
|
NI-9213 with Spring Terminal, NI-9216
with Spring Terminal, NI-9226 with Spring Terminal (Black Connector)
| |||||||||||
|
NI-9217 with Screw Terminal
| |||||||||||||||
|
Environmental
| |||||||||||||||||||||
Ingress protection | IP40 | ||||||||||||||||||||
| |||||||||||||||||||||
Pollution Degree | 2 | ||||||||||||||||||||
|
Indoor use only.
Hazardous Locations
Explosive atmospheres rating | Ex ec IIC T4 Gc |
CCC certificate number | 2021312310000312 |
Safety Guidelines
Operate the product only as described in this document.
Safety Guidelines for Hazardous Voltages
(Screw Terminal and Spring Terminal Products)
If hazardous voltages are connected to the device, take the following precautions. A hazardous voltage is a voltage greater than 42.4 V peak voltage or 60 V DC to earth ground.
You may connect signals which may be floating at hazardous voltages only to the products with screw terminal or spring terminal connectors. Do not connect signals which may be floating at hazardous voltages to the products with DSUB or mini-TC connectors.
Safety Guidelines for Hazardous Locations
These products have been evaluated as Ex ec IIC T4 Gc equipment and are CCC certified. Each product is suitable for use within ambient temperatures of -40 °C ≤ Ta ≤ 70 °C in either nonhazardous locations or Zone 2 hazardous locations. If you are using the products in Gas Group IIC hazardous locations, you must use the device in an NI chassis that has been evaluated as Ex ec IIC T4 Gc equipment.
Follow these guidelines if you are installing the product in a potentially explosive environment. Not following these guidelines may result in serious injury or death.
Safety Voltages
NI-9210 with Spring Terminal
Connect only voltages that are within the following limits:
Channel-to-COM | ±30 V maximum | ||||||||||||
|
NI-9210 with Mini-TC
Connect only voltages that are within the following limits:
Channel-to-COM | ±30 V maximum | ||||||||||||
|
NI-9211
Connect only voltages that are within the following limits:
Channel-to-COM | ±30 V maximum | ||||||||||||
|
NI-9212
NI-9212 and TB-9212 with Screw Terminal
Connect only voltages that are within the following limits:
Channel-to-COM | ±30 V maximum | ||||||||||||||||||
| |||||||||||||||||||
|
NI-9212 and TB-9212 with Mini-TC
Connect only voltages that are within the following limits:
Channel-to-COM | ±30 V maximum | ||||||
| |||||||
|
NI-9213 with Push-In Spring Terminal
(Black/Orange Connector)
Connect only voltages that are within the following limits:
Between any two terminals | ±30 V maximum | ||||||
Channel-to-COM | ±30 V maximum | ||||||
Channel-to-channel | None | ||||||
|
NI-9213 with Spring Terminal (Black
Connector)
Connect only voltages that are within the following limits:
Between any two terminals | ±30 V maximum | ||||||||||||
|
NI-9214
Connect only voltages that are within the following limits:
Between any two terminals | ±30 V maximum | ||||||||||||
|
NI-9216 with Push-In Spring Terminal, NI-9226 with Push-In Spring Terminal (Black/Orange Connector), NI-9216 with Spring Terminal, NI-9226 with Spring
Terminal (Black Connector)
Connect only voltages that are within the following limits:
Channel-to-COM | ±30 V maximum | ||||||
Channel-to-channel isolation | None | ||||||
|
NI-9216 with DSUB, NI-9226 with DSUB
Channel-to-COM | ±30 V maximum | ||||||||||||
Channel-to-channel isolation | None | ||||||||||||
|
NI-9217
Connect only voltages that are within the following limits:
| |||||||||||||||||||||
|
Installing C Series Modules
Verify that power is not connected to the I/O connector(s) on the C Series module.
Removing C Series Modules
Verify that power is not connected to the I/O connector(s) on the C Series module before you remove a module from the chassis.
Safety Compliance and Hazardous Locations Standards
This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:
- IEC 61010-1
- IEC 60079-0, IEC 60079-7
- GB/T3836.1, GB/T3836.3
Product Certifications and Declarations
To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link.
Worldwide Support and Services
NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504, USA.
In This Section
- Physical Characteristics
- NI-9210 with Spring Terminal
- NI-9210 with Mini-TC
- NI-9211 with Screw Terminal
- NI-9212 (TB-9212 with Screw Terminal),
NI-9214 (TB-9214)
- NI-9212 (TB-9212 with Mini-TC)
- NI-9213 with Push-In Spring Terminal,
NI-9216 with Push-In Spring Terminal, NI-9226 with Push-In Spring Terminal (Black/Orange
Connector)
- NI-9213 with Spring Terminal, NI-9216
with Spring Terminal, NI-9226 with Spring Terminal (Black Connector)
- NI-9217 with Screw Terminal
- NI-9210 with Spring Terminal
- Environmental
- Hazardous Locations
- Safety Guidelines
- Safety Voltages
- NI-9210 with Spring Terminal
- NI-9210 with Mini-TC
- NI-9211
- NI-9212
- NI-9213 with Push-In Spring Terminal
(Black/Orange Connector)
- NI-9213 with Spring Terminal (Black
Connector)
- NI-9214
- NI-9216 with Push-In Spring Terminal, NI-9226 with Push-In Spring Terminal (Black/Orange Connector), NI-9216 with Spring Terminal, NI-9226 with Spring
Terminal (Black Connector)
- NI-9216 with DSUB, NI-9226 with DSUB
- NI-9217
- NI-9210 with Spring Terminal
- Installing C Series Modules
- Removing C Series Modules
- Safety Compliance and Hazardous Locations Standards
- Product Certifications and Declarations
- Worldwide Support and Services