This document contains the LabWindows/CVI known issues that were discovered before and since the release of LabWindows/CVI 2020. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.
Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
1225361 |
Ini_GetStringCopy Causes Fatal Run-Time Error in ANSI Encoded ApplicationCVI throws a General Protection Fault error when Ini_GetStringCopy is used to look for a key/tag under the following conditions:
Workaround: Complete one of the following workarounds:
|
Reported Version: LabWindows/CVI: 2020 Resolved Version: LabWindows/CVI 2020 f1 Added: May 5, 2021 |
|
1179817 |
Localization Utility Tool Crashes When Loading a Translated UI PanelThe LabWindows/CVI 2020 Localization Utility tool crashes when loading a translated UI panel that contains a TAB control. Workaround: There is currently no known workaround for this issue. Use LabWindows / CVI 2019 or earlier.
|
Reported Version: LabWindows/CVI: 2020 Resolved Version: LabWindows/CVI 2020 f1 Added: May 5, 2021 |
|
1242461 |
Cannot Launch External Application That Requires Elevated PermissionA LabWindows/CVI 2020 application crashes or fails to launch an external application if the external application requires elevated permission. Workaround: There is currently no known workaround for this issue. Use LabWindows / CVI 2019 or earlier.
|
Reported Version: LabWindows/CVI: 2020 Resolved Version: LabWindows/CVI 2020 f1 Added: May 5, 2021 |
|
1523486, 1618530 |
Cannot Send Commands from a CVI DDE Client to a Non-CVI DDE ServerA DDE client implemented in LabWindows/CVI 2020 cannot send commands to a DDE server implemented in some other development environment.
Workaround: There is currently no known workaround for this issue. |
Reported Version: LabWindows/CVI: 2020 Resolved Version: LabWindows/CVI 2020 f2 Added: Jun 10, 2021 |
|
2227989 |
Printing debug messages is 5 times slower on Windows 10Using DebugPrintf to print debug messages to LabWindows/CVI Debug Output Window is 5 times slower on Windows 10
Workaround: There is currently no known workaround for this issue. |
Reported Version: LabWindows/CVI: 2019 Resolved Version: LabWindows/CVI 2020 f3 Added: N/A |
|
2083403 |
Getting the text of a combobox inside a tree column returns a wrong text in a CVI 2020 ANSI applicationUsing ATTR_LABEL_TEXT attribute to get the text of a combobox inside a tree column returns a wrong text in a CVI 2020 ANSI application.
Workaround: There is currently no known workaround for this issue. |
Reported Version: LabWindows/CVI: 2020 Resolved Version: LabWindows/CVI 2020 f3 Added: N/A |
|
2083361 |
InsertTreeItem always returns 0 in CVI 2020 ASCI applications.Using InsertTreeItem in a CVI 2020 ANSI application always return 0 instead of returning the index of the inserted item. Workaround: There is currently no known workaround for this issue. |
Reported Version: LabWindows/CVI: 2020 Resolved Version: LabWindows/CVI 2020 f3 Added: N/A |
Issues found in this section will not be listed in future known issues documents for this product.
There are currently no issues to list.