Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
202075 |
Unknown error occurs when providing an invalid Dynamic Linq filterA malformed Dynamic Linq query of assets will always return "An unknown error occurred." instead of a description of the error in the query. Workaround: There is currently no known workaround for this issue. |
Reported Version: SystemLink: 19.5 Resolved Version: SystemLink: 20.0 Added: Feb 27, 2020 |
|
950454 |
SystemLink OPC UA tags stop updating if network connections to the server is reconnectedIf the network connection between SystemLink and an OPC UA server is interrupted and then restored, monitored tags stop updating with new values.
Workaround: Delete the monitored tag in the OPC UA connector and re-add it. |
Reported Version: SystemLink: 19.5 Resolved Version: SystemLink: 20.0 Added: Feb 27, 2020 |
|
955323 |
Trend queries do not include the originally selected stepThe trend view of a single selected step displays no data points. If a user selects a single result of a uniquely named step, the resulting graph will be blank.
Workaround: Select multiple steps in query.
|
Reported Version: SystemLink: 19.6 Resolved Version: SystemLink: 20.0 Added: Feb 27, 2020 |
|
959917 |
Jupyter notebook execution service leaks memoryThere is a memory leak in the Jupyter notebook execution service.
Workaround: There is currently no known workaround for this issue. |
Reported Version: SystemLink: 19.6 Resolved Version: SystemLink: 20.0 Added: Feb 27, 2020 |
|
960619 |
Dynamic Linq may return unexpected results for list property queriesDynamic Linq queries for list properties that do not contain a specific value will also return values that have a null value for that property.
Workaround: There is currently no known workaround for this issue. |
Reported Version: SystemLink: 19.6 Resolved Version: SystemLink: 20.0 Added: Feb 27, 2020 |
|
966396 |
System Images page does not load when both Windows and NI Linux Real-Time clients are selectedWhen at least one Windows and one NI Linux Real-Time client are selected and the system images page is open, the page may hang and timeout before a list of images can be returned.
Workaround: Select only Windows or only NI Linux Real-Time clients before viewing available images.
|
Reported Version: SystemLink: 19.6 Resolved Version: SystemLink: 20.0 Added: Feb 27, 2020 |
|
1028162 |
SaltStack security vulnerabilities CVE-2020-11651, CVE-2020-11652SaltStack releases 2019.2.4 and 3000.2 address two critical
vulnerabilities in prior versions of Salt master service.
Workaround: These vulnerabilities can be partially mitigated by following the steps recommended by SaltStack at https://community.saltstack.com/blog/critical-vulnerabilities-update-cve-2020-11651-and-cve-2020-11652/
|
Reported Version: LabVIEW Communications System Design Suite: 5.0 | LabVIEW NXG Real-Time Module: 5.0 | LabVIEW NXG Web Module: 5.0 | SystemLink: 19.6 | SystemLink: 20.0 Resolved Version: SystemLink: 20.0 Added: May 18, 2020 |
These patches currently do not have any special instructions.