This document contains the LabVIEW NXG 5.0 known issues that were discovered before and since the release of LabVIEW NXG 5.0. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.
Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
575800 | 514789 |
Autotuning PID Online.VI Example Reads Proportional Gain 'NaN' with the Relay Technique.When running the Autotuning PID Online.vi example, with the Relay Technique the "Tuned PID gains" output of proportional gain (Kc) shows "NaN" when the program believes tuning is completed by flashing "tuning completed?". Workaround: Tune the individual terms first. Start by first tuning for P until the response is stable. Then continue to tune by switching to PI. Lastly, repeat the process for PID. |
Reported Version: LabVIEW NXG 1.0 Resolved Version: N/A Added: May 21, 2017 |
53381 | 112702 |
Cannot read file that shows up as zero bytes.Linux, Unix and Macs can have files that show up on disk as zero bytes but actually have data that can be read. If you use a Read Binary File primitive on these files you will return an empty string. Workaround: Read a large number of bytes and handle the end of file error that you will receive. |
Reported Version: LabVIEW NXG 1.0 Resolved Version: N/A Added: May 21, 2017 |
59104 | 678830 |
Dictionaries are only found in specific language cultureParent cultures will not find the dictionary even if the language matches the parent culture. As a result, localization will not happen. Workaround: Place the dictionary into a language-specific folder, e.g. de-DE, de-CH, de-LI, etc |
Reported Version: LabVIEW NXG 2.0 Resolved Version: N/A Added: Feb 25, 2018 |
60727 | 599434 |
Dynamic dispatch controls are not supported inside structuresWorkaround: Remove the control from the structure and the error will clear. |
Reported Version: LabVIEW NXG 1.0 Resolved Version: N/A Added: Feb 25, 2018 |
60729 | 620473 |
Element names inside Typedef Clusters or Rings may not show localized namesWhen looking at names of elements contained within a Typedef Cluster or Ring, the name may appear in English rather than the appropriate localized language. Workaround: Close out of NXG and re-open. Open from the project. |
Reported Version: LabVIEW NXG 1.0 Resolved Version: N/A Added: Feb 25, 2018 |
61481 | 599881 |
Empty folders in project don't show up in the files pane when opening a projectWhen you open a project with empty folders, those don't show up in the files pane. Workaround: There is currently no known workaround for this issue. |
Reported Version: LabVIEW NXG 1.0 Resolved Version: N/A Added: Jan 22, 2018 |
53111 | 662414 |
Error & Warnings Panel continuously expands and collapses after repeated pinning and unpinningNormally, The Error & Warnings panel pops up when the mouse is hovered over it. In some cases, the Errors and Warnings window may expand and collapsed continuously after pinning and unpinning the Errors and Warnings panel. Workaround: Click the tab. |
Reported Version: LabVIEW NXG 2.0 Resolved Version: N/A Added: Jan 22, 2018 |
75162 |
Event Loop, In Place Element Structure, and Timed Loop do not create correctly when dragging from Right to Left (instead of Left to Right)There are some structures that do not create correctly when dragging from right to left (instead of left to right). The structure will create and expand in the Y-axis correctly but will stay to the right of the point where the mouse clicked before dragging, and remain in the smallest width possible. I expect all of them to expand in the X-axis to follow the mouse drag when moving to the left. Workaround: Create the structures left to right, instead of right to left. |
Reported Version: LabVIEW NXG 2.0 Resolved Version: N/A Added: May 17, 2020 |
|
93638 | 661948 |
Expand/Collapse glyph remains after deleting all contents of a classWhen you delete all contents of a class, it still displays the Expand/Collapse glyph in the project, as if there were members to be shown or hidden. Workaround: There is currently no known workaround for this issue. |
Reported Version: LabVIEW NXG 2.0 Resolved Version: N/A Added: Jan 22, 2018 |
989174 |
GVI with C Node broken after project reload and force recompile.Forcing a recompile of a GVI which includes a C Node will appear broken when you open your project again. Workaround: Delete LabVIEW NXG's Compiled Code Cache (".cache" folder)
|
Reported Version: LabVIEW NXG 5.0 | Vision Development Module: 2020 Resolved Version: N/A Added: May 17, 2020 |
|
127716 | 630075 |
IO constants cannot be resized when contained within a cluster connected to a G Type.IO constants can be resized manually when contained within a cluster constant. However, IO constants cannot be resized once the containing cluster is connected to a G Type. The IO control in the G Type can be resized but this change is not reflected in any connected constants. Workaround: Disconnect the cluster from the G Type, resize the IO constant, and then reconnect to the G Type. |
Reported Version: LabVIEW NXG 1.0 Resolved Version: N/A Added: May 21, 2017 |
982812 |
LabVIEW NXG crashes when using any of the Database Connectivity APIsCrash using the "Database Connectivity" API on some computers. We have mostly noticed customers facing this issue on Lenovo X1 laptops. However, it could happen on other computers too. Crash log: ErrorId: 0x6AD7DF6F Message: Unhandled Task Exception Error message: attempt to write a readonly database attempt to write a readonly database Exception: SQLiteException The issue can also be reproduced by opening any of the Database examples. These examples can be found here in the NXG welcome page: Examples > Programming Basics > Connectivity > Database
Workaround: Set the 'Default' value to empty for this key in Windows Registry: Computer\HKEY_CLASSES_ROOT\TypeLib\{51C0003F-0741-4D1A-A612-891EB6928B5B}\1.0\0\win64
|
Reported Version: LabVIEW NXG 4.0 | LabVIEW NXG 5.0 Resolved Version: N/A Added: Jul 30, 2020 |
|
576648 | 711967 |
LabVIEW NXG does not function correctly when license files are moved from default location.LabVIEW NXG will not function when the license files for NXG have been removed from the C:\ProgramData\National Instruments\License Manager\Licenses folder.
The behavior will be that the splash screen will appear, then disappear and nothing happens. Workaround: Move the license files back into the correct location. |
Reported Version: LabVIEW NXG 2.1.1 Resolved Version: N/A Added: May 17, 2020 |
61527 | 641719 |
Projects with large file hierarchy error out during conversion with unclear error messageWorkaround: Make shorter file paths initially so the added hierarchy doesn't extend beyond Windows file path limits |
Reported Version: LabVIEW NXG 1.0 Resolved Version: N/A Added: Feb 25, 2018 |
56269 | 643608 |
Right clicking on a tunnel of queue of numeric type shows the numeric paletteFor most data types, the right click menu from the queue terminals shows the palette queue. Right clicking on a tunnel of numeric type shows the numeric palette. Workaround: Manually drop from the queue palette instead of right-clicking. |
Reported Version: LabVIEW NXG 1.0 Resolved Version: N/A Added: Jan 22, 2018 |
52711 | 482816 |
Selection in Array of Clusters of Arrays constant loses focus.Selecting an array inside a cluster inside another array loses focus when hovering over another element of the top array. This makes it difficult to edit the items in the inner-most array. Workaround: There is currently no known workaround for this issue. |
Reported Version: LabVIEW NXG 1.0 Resolved Version: N/A Added: May 21, 2017 |
53045 | 631907 |
Some keyboard shortcuts don't work with an AZERTY keyboardWorkaround: There is currently no known workaround for this issue. |
Reported Version: LabVIEW NXG 2.0 Resolved Version: N/A Added: Jan 22, 2018 |
61325 | 605135 |
Some strings remain in English rather than localized language when converted to LabVIEW NXGWhen setting a localized dictionary and converting from LabVIEW to LabVIEW NXG, some strings may remain in English. Specifically, strings that are labels instead of captions will appear in English Workaround: Set a caption for controls prior to conversion or update text after conversion |
Reported Version: LabVIEW NXG 1.0 Resolved Version: N/A Added: Feb 25, 2018 |
575530 | 584767 |
Some UI elements in the environment may not display correctly using custom DPI settings.Some UI elements may display incompletely if using a custom Windows DPI setting of 125%, or similar. Workaround: Use default DPI settings. |
Reported Version: LabVIEW NXG 1.0 Resolved Version: N/A Added: May 21, 2017 |
357380 | 733974 |
SSH Connection to Linux RT target with non-blank root password failsAttempting to connect to a Linux RT target via SSH when the root password is non-blank fails. Workaround: Modify /etc/ssh/sshd_config by changing “PermitEmptyPasswords yes” to “PermitEmptyPasswords no” and reboot the controller. |
Reported Version: LabVIEW NXG 1.0 Resolved Version: N/A Added: May 16, 2019 |
53058 | 660805 |
Windows "line per notch" scroll wheel settings do not apply to NXGThe scroll wheel movement amount does correlate to the scroll size defined in the Windows mouse settings. For example there's no difference in the amount of block diagram scrolled whether the set to 1 line per notch or 10 lines per notch. Workaround: There is currently no known workaround for this issue. |
Reported Version: LabVIEW NXG 2.0 Resolved Version: N/A Added: Jan 22, 2018 |
88126 | 644397 |
Workbooks do not restore maximized after minimizing the environment window with a maximized workbook open.A maximized workbook window will minimize when the environment window is minimized. Restoring the environment window will also restore the workbook window but not in the maximized view. Workaround: Maximize the workbook window manually after restoring the environment window. |
Reported Version: LabVIEW NXG 1.0 Resolved Version: N/A Added: May 17, 2020 |
Issues found in this section will not be listed in future known issues documents for this product.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
52886 | 596295 |
Measurement Panel created for an array of task constants does not propagate name.When a Measurement Panel is created from an empty task constant inside of an array, a new task will be generated for it and a name will be assigned. However, this name will not be automatically updated on the original task constant inside the array. Workaround: Manually rename the task constant. |
Reported Version: LabVIEW NXG 1.0 Resolved Version: N/A Added: May 21, 2017 |