This document contains the VeriStand 2020 known issues that were discovered before and since the release of VeriStand 2020 R3. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.
Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
115960 | 572887 |
Setting the Frame Type Option in the Raw Data Frame Configuration Page Has no EffectAs the frame type is pulled from the XNET database, the system definition setting does not affect the XNET configuration.
Workaround: Set the frame type in the XNET database. Do not use the Raw Data Frame Type Configuration option in the system definition.
|
Reported Version: VeriStand 2014 Resolved Version: N/A Added: Jan 17, 2020 |
114970 |
LIN Scheduler is started before the session resulting in 500 ms of no response frames.When XNET is configured to be a LIN master, the LIN scheduler appears to start before the outgoing XNET sessions are started. This results in the LIN master scheduler transmitting headers while the master's slave task is unprepared to transmit responses. As a result, the receiving LIN interface will instead detect "No Response" frames.
Workaround: If you do not need to inline outgoing frames, you can deselect this option and the issue will not occur.
|
Reported Version: VeriStand 18.0 Resolved Version: N/A Added: N/A |
|
1069833 |
Show frame IDs in hexadecimal format setting not fully appliedEnabling the setting "Show frame IDs in hexadecimal format" does not completely apply. The ID in the name field remains in decimal, while the frame ID field updates properly to hexadecimal, but does not have a radix added.
Workaround: There is currently no known workaround for this issue. |
Reported Version: VeriStand 2020 Resolved Version: N/A Added: N/A |
|
1095791 |
Deployment error -200077 with a module configured for HWTSP and Sample Rate less than 5 HzWhen enabling "Slow Background Conversion Mode" for a module and setting the Sample Rate to be less than 5 Hz, deployment will fail with error -200077.
Workaround: Set the "Sample Rate" to either -1 or any value greater or equal than 5 Hz.
|
Reported Version: VeriStand 2019 Resolved Version: N/A Added: N/A |
Issues found in this section will not be listed in future known issues documents for this product.
There are currently no issues to list.
Explore Support Content and Product Documentation
Ask the NI Community
Request Support from an Engineer
A valid service agreement may be required, and support options vary by country