This document contains the FlexLogger R3 known issues that were discovered before and since the release of FlexLogger 2020 R3. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.
Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
1379207 |
FlexLogger Crashes While Opening Projects That Have at Least One Plugin ConfiguredFlexLogger may crash while opening a project that meets the following conditions:
Workaround:
|
Reported Version: FlexLogger 2020 R2 Resolved Version: FlexLogger 2021 R2 Added: N/A |
|
1125138 |
Formula Output Incorrect When Operating on Both Digital and Analog ChannelsFlexLogger may map channels incorrectly and produce the wrong output from any formula that includes both digital (any channel that has a boolean value) and analog channels (any channel that has a numeric value). If the name of a digital channel comes alphabetically before the name of any analog channels in the formula, then the channels will get mapped to the wrong position in the formula. For example, the formula "b_digital ? a_analog : c_analog" would be mapped incorrectly because the name "b_digital" comes before "c_analog" alphabetically.
Workaround: Rename channels so that, alphabetically, all analog channels are before any digital channels. You can use the attached tool, FlexLogger2020FormulaDiagnosticUtility, to determine if any of your projects may be affected by this issue.
|
Reported Version: FlexLogger 2020 R2 Resolved Version: FlexLogger 2020 R4.1 Added: Oct 28, 2020 |
|
1102692 |
FlexLogger Temporarily Hangs When a TSN-Enabled Ethernet cDAQ with an XNET Module is PresentFlexLogger temporarily hangs and becomes unresponsive for tens of seconds when a TSN-Enabled Ethernet cDAQ containing an XNET module is present at project load or added later.
Workaround: Wait for the application to become responsive.
|
Reported Version: FlexLogger 2020 R3 Resolved Version: FlexLogger 2021 R1 Added: Sep 10, 2020 |
|
1116657 |
Adding DAQ Channels in a Non-sequential Order Corrupts Anything Referencing a ChannelWhen new DAQ channels are configured in non-sequential order within a device (PXI, cDAQ, FieldDAQ, USB, etc.), any existing or future calculated channels, plugins, logging triggers, and events reference the wrong channel. This means that calculated channels and plugins will be operating on the wrong data and events and triggers may not fire when expected. To obtain more information, click the link below.
Workaround: Save and re-open your project after you have finished all new channel configurations and before you validate the project.
|
Reported Version: FlexLogger 2020 R1 Resolved Version: FlexLogger 2020 R4 Added: Sep 10, 2020 |
|
957223 |
Numeric Indicator increases digits of precision at random times in FlexLoggerNumeric indicators configured with 'Digits of Precision' can display more digits of precision than specified for values near zero.
Workaround: There is currently no known workaround for this issue.
|
Reported Version: FlexLogger 2019 R4.1 Resolved Version: FlexLogger 2020 R4 Added: Sep 10, 2020 |
|
1065682 |
Update Channel Units VI does not function for consumer channelsFor plugins, Update Channel Units VI does not work for set point (consumer) channels.
Workaround: Re-create the consumer channels with the new units.
|
Reported Version: FlexLogger Plugin Development Kit 1.2 | FlexLogger 2020 R2 Resolved Version: FlexLogger 2020 R4 Added: Sep 10, 2020 |
Issues found in this section will not be listed in future known issues documents for this product.
There are currently no issues to list.