NI does not actively maintain this document.
This content provides support for older products and technology, so you may notice outdated links or obsolete information about operating systems or other relevant products.
Note: NI WSN products are not supported beyond LabVIEW 2015. If you have questions on migrating products, contact technical support at ni.com/support.
This article lists NI software versions that support NI WSN devices.
NI strongly recommends using the latest version of NI-WSN and LabVIEW with NI-WSN hardware.
To Download the latest version of the NI-WSN driver click here.
To Download the latest version of the NI-RIO driver click here.
For the latest version of LabVIEW, click here.
Note: If no driver version is listed, then the module is not supported in that gateway or node.
Hardware | NI LabVIEW (32 bit)**** | NI LabVIEW Module (32 bit) | NI-WSN | Other NI Driver Requirements |
---|---|---|---|---|
Nodes | ||||
NI WSN-3202 | 8.6.1 or later | WSN Module 8.6.1 or later | 1.0.2 or later | - |
***NI WSN-3212 | 8.6.1 or later | WSN Module 2010 or later | 1.3.0 or later | - |
***NI WSN-3226 | 8.6.1 or later | WSN Module 2010 or later | 1.3.0 or later | - |
NI WSN-3214 | 2011 or later | WSN Module 2011 or later | 1.3.1 or later | - |
NI WSN-3230 | 2011 or later | WSN Module 2011 or later | 1.3.0 or later | - |
NI WSN-3231 | 2011 or later | WSN Module 2011 or later | 1.3.0 or later | - |
Gateways | ||||
NI WSN-9791 | 8.6.1 or later | - | 1.0.2 or later | - |
*NI 9792 | 2010 or later | 2010 Real-Time Module or later | 1.3.0 or later | - |
**NI 9795 | 2011 or later | 2011 Real-Time Module or later | 1.3.0 or later | NI-RIO 4.0 or later |
* To use the NI 9792 WSN Real-Time Gateway you must install both NI LabVIEW 2009 Service Pack 1 (SP1) (32-bit) or later and NI LabVIEW 2009 SP1 (32-bit) Real-Time Module or later.
** To use the NI 9795 WSN C Series Gateway you must have LabVIEW and LabVIEW Real-Time 2011 or later and a CompactRIO that supports the RIO Scan Interface (RSI) or Scan Engine.
*** If using the LabVIEW WSN Module on the NI WSN-3212 and 3226 nodes labVIEW 2010 base/full/professional or later is required.
**** NI-WSN is not supported in LabVIEW 2014.
OS | NI-WSN | NI LabVIEW | NI LabVIEW WSN Module |
---|---|---|---|
Windows 10 | Current1 | Current1 | Current1 |
Windows 8 | Current2 | Current2 | Current2 |
Windows 7 | Current | Current | Current |
Windows Vista | Current | Current | Current |
Windows XP (32 bit only) | Current | Current | Current |
Windows 2000 SP3 | 1.0.2 | 2009 SP1 | 2009 SP1 |
"Current" indicates that the latest version of NI-WSN supports the indicated operating system.
1 - Please see NI Product Compatibility for Microsoft Windows 10
2 - Please see Known Compatibility Issues Between Windows 8 and NI Products
LabVIEW Version (32 bit) | NI-WSN 1.0.2 | NI-WSN 1.1.0 | NI-WSN 1.2.0 | NI-WSN 1.2.1 | NI-WSN 1.3.0 | NI-WSN 1.3.1 | NI-WSN 1.4 | NI-WSN 1.5 | NI-WSN 15.0 |
---|---|---|---|---|---|---|---|---|---|
8.6.1 | |||||||||
2009 SP1 | |||||||||
2010 SP1 | |||||||||
2011 SP1 | |||||||||
2012 SP1 | |||||||||
2013 SP1 | |||||||||
2014 SP1 | |||||||||
2015 SP1 |
The areas in green represent version of LabVIEW support for the given version of NI-WSN.